颈动脉粥样硬化斑块标准化摄取值:软件挑战与可重复性
研究在101例患者中比较两种软件包测量颈动脉18F-氟脱氧葡萄糖PET标准化摄取值的一致性,发现依感兴趣区位置不同,两种软件的SUV测量差异达9%至21.8%,79%(n=23)的感兴趣区位置差异有统计学意义,分析及导出数据耗时也差异明显。
要点
- 两种软件包测量颈动脉斑块SUV存在9%至21.8%的差异,取决于感兴趣区位置。
- 79%(n=23)的感兴趣区位置两种软件SUV差异有统计学意义。
- 作者强调分析方法标准化对准确性和可重复性的重要性。
核心结论
- 研究强调标准化方法学各方面对确保准确性和可重复性的重要性。
- 医生必须知晓分析PET-CT数据集时,后续随访应尽可能用同一软件包验证,或进行软件包间交叉校准。
研究设计与样本
- 研究纳入101例患者,采集颈动脉18F-FDG PET的SUV,使用两种不同软件包测量。
- 分析开始前进行质量保证检查以标准化技术,测量5至7个解剖部位的数据,每个分析部位勾画10个感兴趣区。
- 进行统计分析比较两种软件包的SUV测量并探索可重复性,同时测量并比较完成每次分析所需时间。
主要发现
- 两种软件包间SUV测量差异为9%至21.8%,取决于感兴趣区位置。
- 79%(n=23)的感兴趣区位置,两种软件包SUV测量差异有统计学意义。
- 两种软件包完成分析和导出数据所需时间也差异很大。
临床怎么用
- 作者认为,分析PET-CT数据集时,后续随访应尽可能用同一软件包验证,或进行软件包间交叉校准。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Positron emission tomography-computed tomography (PET-CT) carotid standardised uptake values (SUV) of 18F-fluorodeoxyglucose (18FDG) have been proposed as an inflammatory biomarker for determining cerebrovascular diseases such as stroke. Consideration of varying methodological approaches and software packages is critical to the calculation of accurate SUVs in cross-sectional and longitudinal patient studies. The aim of this study was to investigate whether or not carotid atherosclerotic plaque SUVs are consistent and reproducible between software packages. 18FDG-PET SUVs of carotids were taken in 101 patients using two different software packages. Quality assurance checks were performed to standardise techniques before commencing the analysis where data from five to seven anatomical sites were measured. A total of ten regions of interest were drawn on each site analysed. Statistical analyses were then performed to compare SUV measurements from the two software packages and to explore reproducibility of measurements. Lastly, the time taken to complete each analysis was measured and compared. RESULTS: Statistically significant differences in SUV measurements, between the two software packages, ranging from 9 to 21.8% were found depending on ROI location. In 79% (n = 23) of the ROI locations, the differences between the SUV measurements from each software package were found to be statistically significant. The time taken to perform the analyses and export data from the software packages also varied considerably. CONCLUSIONS: This study highlights the importance of standardising all aspects of methodological approaches to ensure accuracy and reproducibility. Physicians must be aware that when a PET-CT data set is analysed, subsequent follow-ups must be verified, if possible, with the same software package or cross-calibration between packages should be performed.
引用
- Giannotti N, O'Connell MJ, Foley SJ, et al. Carotid atherosclerotic plaques standardised uptake values: software challenges and reproducibility. EJNMMI Res. 2017. PMID: 28455733. doi:10.1186/s13550-017-0285-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。