文献速递心脏核医学放射性药物与辐射防护

通过铷-82 PET/CT中的CT衰减校正图自动测定心血管风险

Automatic determination of cardiovascular risk by CT attenuation correction maps in Rb-82 PET/CT.
PubMed 文献 · J Nucl Cardiol · 2017-04-04

研究纳入133例连续接受负荷与静息铷-82 PET/CT及低剂量CT衰减校正(CTAC)的患者,并另做专用钙化积分CT(CSCT)。用机器学习算法在CTAC上全自动行冠状动脉钙化(CAC)评分并划分心血管疾病(CVD)风险类别,与CTAC人工标注及CSCT比较。静息与负荷CTAC自动与人工评分的CVD风险分类一致性加权κ分别为0.85和0.89;CSCT与静息CTAC一致性人工κ 0.82、自动κ 0.74,负荷CTAC分别为0.79和0.70。结论认为CTAC自动CAC评分或可在不增加辐射剂量和扫描时间的情况下用于常规CVD风险评估。

要点

  • 静息与负荷CTAC自动与人工评分的CVD风险分类一致性加权κ分别为0.85和0.89。
  • CSCT与静息CTAC风险分类一致性:人工评分κ 0.82,自动评分κ 0.74。
  • CSCT与负荷CTAC风险分类一致性:人工评分κ 0.79,自动评分κ 0.70。

核心结论

  • 从PET/CT的CTAC成分自动行CAC评分,或可在不增加辐射剂量或扫描时间的情况下实现常规CVD风险评估。

研究设计与样本

  • 纳入133例连续接受静息与负荷铷-82 PET/CT并采集低剂量CTAC的患者,所有患者另做专用CSCT。
  • 以CTAC和CSCT的人工CAC标注为参考标准,CTAC中CAC采用既往开发的机器学习算法全自动评分。
  • 按Agatston评分将患者分为CVD风险类别:0、1-10、11-100、101-400、>400。

主要发现

  • 静息CTAC自动与人工评分的CVD风险分类一致性加权κ为0.85,负荷CTAC为0.89。
  • CSCT与静息CTAC风险分类一致性:人工评分κ 0.82,自动评分κ 0.74。
  • CSCT与负荷CTAC风险分类一致性:人工评分κ 0.79,自动评分κ 0.70。

关键数值与推荐

  • CVD风险类别按Agatston评分划分为0、1-10、11-100、101-400、>400。
  • 静息与负荷CTAC自动与人工评分的CVD风险分类一致性加权κ分别为0.85和0.89。
  • CSCT与静息CTAC风险分类一致性:人工评分κ 0.82,自动评分κ 0.74;负荷CTAC:人工评分κ 0.79,自动评分κ 0.70。

临床怎么用

  • 原文结论未据此给出具体临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We investigated fully automatic coronary artery calcium (CAC) scoring and cardiovascular disease (CVD) risk categorization from CT attenuation correction (CTAC) acquired at rest and stress during cardiac PET/CT and compared it with manual annotations in CTAC and with dedicated calcium scoring CT (CSCT). METHODS AND RESULTS: We included 133 consecutive patients undergoing myocardial perfusion 82Rb PET/CT with the acquisition of low-dose CTAC at rest and stress. Additionally, a dedicated CSCT was performed for all patients. Manual CAC annotations in CTAC and CSCT provided the reference standard. In CTAC, CAC was scored automatically using a previously developed machine learning algorithm. Patients were assigned to a CVD risk category based on their Agatston score (0, 1-10, 11-100, 101-400, >400). Agreement in CVD risk categorization between manual and automatic scoring in CTAC at rest and stress resulted in Cohen's linearly weighted κ of 0.85 and 0.89, respectively. The agreement between CSCT and CTAC at rest resulted in κ of 0.82 and 0.74, using manual and automatic scoring, respectively. For CTAC at stress, these were 0.79 and 0.70, respectively. CONCLUSION: Automatic CAC scoring from CTAC PET/CT may allow routine CVD risk assessment from the CTAC component of PET/CT without any additional radiation dose or scan time.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Išgum I, de Vos BD, Wolterink JM, et al. Automatic determination of cardiovascular risk by CT attenuation correction maps in Rb-82 PET/CT. J Nucl Cardiol. 2017. PMID: 28378112. doi:10.1007/s12350-017-0866-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。