18F-FDG PET与MRI表观扩散系数直方图指标与弥漫性内生型脑桥胶质瘤生存期的相关性:儿童脑肿瘤联盟报告
本研究在33例儿童弥漫性内生型脑桥胶质瘤(DIPG)基线18F-FDG PET和MRI表观扩散系数(ADC)直方图指标中,发现PET直方图几乎均为单峰(94%),PET偏度或峰度与无进展生存期(PFS)无显著关联;而ADC增强后偏度较高与PFS较短显著相关(HR 2.56,95%CI 1.11-5.91,P=0.028),ADC与PET像素值负相关程度越高,PFS越差(HR 0.17,95%CI 0.03-0.89,P=0.036)。
要点
- 儿童DIPG基线18F-FDG PET直方图94%为单峰,PET偏度或峰度与PFS无显著关联。
- ADC增强后偏度较高与PFS较短显著相关(HR 2.56,95%CI 1.11-5.91,P=0.028)。
- ADC与PET像素值负相关程度越高,PFS越差(HR 0.17,95%CI 0.03-0.89,P=0.036)。
核心结论
- 儿童DIPG的18F-FDG PET与MR ADC直方图指标呈现不同特征,PET与ADC像素值常呈负相关。
- 较高的负相关程度与更差的PFS相关,可能提示肿瘤内存在更高级别的成分。
研究设计与样本
- 研究纳入儿童脑肿瘤联盟(Pediatric Brain Tumor Consortium)临床DIPG试验中的33例儿童,获取基线脑18F-FDG PET和MRI扫描。
- 将18F-FDG PET图像、钆增强后MR图像和ADC MR图像配准至基线液体衰减反转恢复(FLAIR)MR图像,并在FLAIR及钆增强后MR图像上生成三维感兴趣区及PET和MR ADC直方图。
- 评估指标包括峰值数目、偏度和峰度;分析PET与MR ADC直方图指标的相关性,并将每个肿瘤感兴趣区内PET像素值与MR ADC值进行对应分析。
- 描述这些影像标志物与生存期的关联。
主要发现
- PET直方图几乎均为单峰(94%),双峰占6%。
- PET直方图参数(偏度或峰度)与PFS均无显著关联,但较高的PET钆增强后偏度趋向于更差的PFS(风险比3.48;95%CI 0.75-16.28;P=0.11)。
- 较高的MR ADC钆增强后偏度与较短的PFS显著相关(风险比2.56;95%CI 1.11-5.91;P=0.028),并提示也可能导致较短的总生存期(风险比2.18;95%CI 0.95-5.04;P=0.067)。
- 较高的MR ADC钆增强后峰度趋向于较短的PFS(风险比1.30;95%CI 0.98-1.74;P=0.073)。
- PET与MR ADC像素值呈负相关(采用Pearson相关系数);PET与MR ADC的相关程度与PFS显著正相关,ADC-PET相关值较高的肿瘤PFS更有利(风险比0.17;95%CI 0.03-0.89;P=0.036),提示较高的负相关程度导致较差的PFS。
关键数值与推荐
- PET直方图单峰占94%,双峰占6%。
- PET钆增强后偏度与PFS:风险比3.48(95%CI 0.75-16.28;P=0.11)。
- MR ADC钆增强后偏度与PFS:风险比2.56(95%CI 1.11-5.91;P=0.028)。
- MR ADC钆增强后偏度与总生存期:风险比2.18(95%CI 0.95-5.04;P=0.067)。
- MR ADC钆增强后峰度与PFS:风险比1.30(95%CI 0.98-1.74;P=0.073);ADC-PET相关值与PFS:风险比0.17(95%CI 0.03-0.89;P=0.036)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The purpose of this study was to describe baseline 18F-FDG PET voxel characteristics in pediatric diffuse intrinsic pontine glioma (DIPG) and to correlate these metrics with baseline MRI apparent diffusion coefficient (ADC) histogram metrics, progression-free survival (PFS), and overall survival. Methods: Baseline brain 18F-FDG PET and MRI scans were obtained in 33 children from Pediatric Brain Tumor Consortium clinical DIPG trials. 18F-FDG PET images, postgadolinium MR images, and ADC MR images were registered to baseline fluid attenuation inversion recovery MR images. Three-dimensional regions of interest on fluid attenuation inversion recovery MR images and postgadolinium MR images and 18F-FDG PET and MR ADC histograms were generated. Metrics evaluated included peak number, skewness, and kurtosis. Correlation between PET and MR ADC histogram metrics was evaluated. PET pixel values within the region of interest for each tumor were plotted against MR ADC values. The association of these imaging markers with survival was described. Results: PET histograms were almost always unimodal (94%, vs. 6% bimodal). None of the PET histogram parameters (skewness or kurtosis) had a significant association with PFS, although a higher PET postgadolinium skewness tended toward a less favorable PFS (hazard ratio, 3.48; 95% confidence interval [CI], 0.75-16.28 [P = 0.11]). There was a significant association between higher MR ADC postgadolinium skewness and shorter PFS (hazard ratio, 2.56; 95% CI, 1.11-5.91 [P = 0.028]), and there was the suggestion that this also led to shorter overall survival (hazard ratio, 2.18; 95% CI, 0.95-5.04 [P = 0.067]). Higher MR ADC postgadolinium kurtosis tended toward shorter PFS (hazard ratio, 1.30; 95% CI, 0.98-1.74 [P = 0.073]). PET and MR ADC pixel values were negatively correlated using the Pearson correlation coefficient. Further, the level of PET and MR ADC correlation was significantly positively associated with PFS; tumors with higher values of ADC-PET correlation had more favorable PFS (hazard ratio, 0.17; 95% CI, 0.03-0.89 [P = 0.036]), suggesting that a higher level of negative ADC-PET correlation leads to less favorable PFS. A more significant negative correlation may indicate higher-grade elements within the tumor leading to poorer outcomes. Conclusion:18F-FDG PET and MR ADC histogram metrics in pediatric DIPG demonstrate different characteristics with often a negative correlation between PET and MR ADC pixel values. A higher negative correlation is associated with a worse PFS, which may indicate higher-grade elements within the tumor.
引用
- Zukotynski KA, Vajapeyam S, Fahey FH, et al. Correlation of 18F-FDG PET and MRI Apparent Diffusion Coefficient Histogram Metrics with Survival in Diffuse Intrinsic Pontine Glioma: A Report from the Pediatric Brain Tumor Consortium. J Nucl Med. 2017. PMID: 28360212. doi:10.2967/jnumed.116.185389
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。