文献速递甲状腺核医学核素与放射性配体治疗

晚期碘-124 PET/CT 摄取测量:良性甲状腺疾病中适宜检查方案的评估

Late 124I PET/CT Uptake Measurement-Assessment of Appropriate Examination Protocol in Benign Thyroid Diseases.
PubMed 文献 · Clin Nucl Med · 2017-01-01

PURPOSE: This study aimed at investigating the performance of late I PET/CT for radioiodine uptake (RAIU) measurement at 336 hours after administration in patients with benign thyroid diseases requiring radioiodine therapy.…

要点

  • 作者提出「适宜扫描时间-活度乘积」参数,以建立经济合理的检查方案。

核心结论

  • 本研究证实晚期碘-124 PET/CT可作为良性甲状腺疾病患者放射性碘摄取测量的替代方法。
  • 作者提出「适宜扫描时间-活度乘积」参数,以期实现经济合理的检查方案。

研究设计与样本

  • 研究纳入18例需放射性碘治疗的良性甲状腺疾病患者。
  • 于给药1 MBq碘-124后336小时采集40分钟列表模式PET数据集。
  • 通过5秒至40分钟不同重建间隔模拟不同扫描时长,测量甲状腺总活度。

主要发现

  • 重建间隔短于2分钟时未获得足够的一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: This study aimed at investigating the performance of late I PET/CT for radioiodine uptake (RAIU) measurement at 336 hours after administration in patients with benign thyroid diseases requiring radioiodine therapy. Special attention was paid to the comparability of I uptake (I-RAIU) to the clinical standard (I-RAIU, probe measurement). Considering cost aspects, we sought to establish an economically reasonable examination protocol based on scan duration and administered activity. METHODS: List-mode PET data sets of 40-minute acquisition time were acquired 336 hours after administration of 1 MBq I in 18 patients. Different scan durations were simulated by different reconstruction intervals (RIs) ranging from 5 seconds to 40 minutes, and total thyroid activity was measured. Mean I-RAIU levels of each RI were compared with mean I-RAIU levels (3 MBq). A hypothetical scan duration or hypothetical activity, respectively, was sought by means of a proportion equation, considering that the length of an RI is equitable to a hypothetical activity. RESULTS: After 336 hours, the mean total thyroid activity was 254 ± 7.7 kBq for I and 26.9 ± 8.7 kBq for I. The mean I-RAIU and I-RAIU showed high levels of agreement for RI from 2 minutes to 40 minutes. Reconstruction interval shorter than 2 minutes did not result in sufficient agreement. CONCLUSIONS: The present study confirmed the feasibility of late I PET/CT as alternative method for RAIU measurement in patients with benign thyroid diseases; 1 MBq I PET/CT scans as short as 2 minutes resulted in RAIU levels comparable to those of standard I-RAIU. The parameter "appropriate scan-duration activity product" is proposed to enable an economically reasonable examination protocol.

来源:Clin Nucl Med,查看原文。版权归原作者所有。

引用

  1. Freesmeyer M, Gabler AS, Kühnel C, et al. Late 124I PET/CT Uptake Measurement-Assessment of Appropriate Examination Protocol in Benign Thyroid Diseases. Clin Nucl Med. 2017. PMID: 28418955. doi:10.1097/RLU.0000000000001677

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。