多中心评估18F-FDG PET/CT定量测量癌症治疗反应的可变性
本研究将30例肿瘤患者的治疗前后18F-FDG PET/CT图像分发给15个美国及国际中心的22名阅片者,评估治疗反应定量参数的可重复性。所有读数中,最热肿瘤的SUVmax百分比变化组内相关系数为0.894(95%CI 0.813-0.941);当仅纳入选择与参考阅片相同靶肿瘤的读数时,组内相关系数升至0.944(95%CI 0.841-0.989)。结论认为多中心、多阅片者测量的肿瘤SUV变化高度相关,选择相同靶肿瘤可进一步提高相关性。
要点
- 15个中心22名阅片者对30例患者治疗前后PET/CT进行SUV定量测量。
- 所有读数中%ΔSUVmax的组内相关系数为0.894(95%CI 0.813-0.941)。
- 选择相同靶肿瘤时%ΔSUVmax组内相关系数为0.944(95%CI 0.841-0.989)。
核心结论
- 多中心、多阅片者测量的肿瘤SUV变化显示高度相关性,选择相同靶肿瘤进一步提高相关性。
研究设计与样本
- 研究纳入30例肿瘤患者的治疗前后配对18F-FDG PET/CT图像,分发给15个美国及国际中心的22名阅片者。
- 1名阅片者知晓完整病史(参考阅片),其余21名阅片者不知晓。
- 阅片者从每份研究中选取单个最热肿瘤,并对该靶病灶和肝脏进行SUV测量。
主要发现
- 所有读数(n=638)中,最热肿瘤SUVmax百分比变化(%ΔSUVmax)的组内相关系数为0.894(95%CI 0.813-0.941),个体等效系数为1.931(95%CI 0.568-6.449)。
- 仅纳入选择与参考阅片相同靶肿瘤的测量(n=486)时,%ΔSUVmax的组内相关系数为0.944(95%CI 0.841-0.989),个体等效系数为-0.688(95%CI -1.810至-0.092)。
- 经瘦体重校正的肝脏SUVmean绝对变化的一致性界限(平均偏倚±2SD)上限为0.13 g/mL,下限为-0.13 g/mL。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
The aim of this study was to assess the interobserver variability of quantitative 18F-FDG PET/CT parameters used in assessments of treatment response across multiple sites and readers. Methods: Paired pre- and posttreatment 18F-FDG PET/CT images of 30 oncologic patients were distributed to 22 readers across 15 U.S. and international sites. One reader was aware of the full medical history (readreference) of the patients, whereas the 21 other readers were unaware. The readers selected the single hottest tumor from each study, and made SUV measurements from this target lesion and the liver. Descriptive statistics, percentage changes in the measurements, and their agreements were obtained. Results: The intraclass correlation coefficient for the percentage change in SUVmax (%ΔSUVmax) of the hottest tumor was 0.894 (95% confidence interval [CI], 0.813-0.941), and the individual equivalence coefficient was 1.931 (95% CI, 0.568-6.449) when all reads were included (n = 638). When only the measurements that selected the same target tumor as the readreference (n = 486) were included, the intraclass correlation coefficient for the %ΔSUVmax was 0.944 (95% CI, 0.841-0.989), and the individual equivalence coefficient was -0.688 (95% CI, -1.810 to -0.092). The absolute change in SUVmean of liver corrected for lean body mass showed upper and lower limits of agreement (average bias ± 2 SDs) of 0.13 and -0.13 g/mL. Conclusion: The quantitative tumor SUV changes measured across multiple sites and readers show a high correlation. Selection of the same tumor target among readers further increased the degree of correlation.
引用
- O JH, Jacene H, Luber B, et al. Quantitation of Cancer Treatment Response by 18F-FDG PET/CT: Multicenter Assessment of Measurement Variability. J Nucl Med. 2017. PMID: 28360211. doi:10.2967/jnumed.117.189605
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。