文献速递心脏核医学

多中心试验:MPI SPECT/CTA 第二代融合定量心肌危险区域对阻塞性冠心病的诊断效能

Diagnostic performance of the quantification of myocardium at risk from MPI SPECT/CTA 2G fusion for detecting obstructive coronary disease: A multicenter trial.
PubMed 文献 · J Nucl Cardiol · 2017-02-13

该多中心研究纳入48例接受静息/负荷MPI、CTA及ICA的患者,基于第二代3D MPI/CTA融合框架定量心肌危险区域(MAR),分别用MPI单独(MARp)、CTA单独(MARa)和融合信息(MARf)估算MAR,以ICA解剖结果为参考标准生成ROC曲线。结果显示,在≥70%狭窄标准下,MARf检测CAD的AUC为0.88(CI=0.75-0.95),高于MARp的0.82(CI=0.69-0.92)和MARa的0.75(CI=0.60-0.86);MARf对CAD定位(所有血管)的AUC显著高于MARa或MARp或两者。结论认为MPI-CTA融合成像较MPI或CTA单独提供增量诊断信息。

要点

  • 在≥70%狭窄标准下,MARf检测CAD的AUC为0.88(CI=0.75-0.95)。
  • MARf对CAD定位(所有血管)的AUC显著高于MARa或MARp或两者。
  • 结论认为MPI-CTA融合成像较MPI或CTA单独提供增量诊断信息。

核心结论

  • 以ICA为参考标准、MAR为定量参数、AUC为诊断效能指标,MPI-CTA融合成像在CAD诊断和定位方面较MPI或CTA单独提供增量诊断信息。

研究设计与样本

  • 多中心试验,分析来自3个不同机构的48例患者的静息/负荷MPI、CTA和ICA检查资料。

主要发现

  • 在≥70%狭窄标准下,MARf检测CAD的AUC为0.88(CI=0.75-0.95)。
  • 在≥70%狭窄标准下,MARp检测CAD的AUC为0.82(CI=0.69-0.92)。
  • 在≥70%狭窄标准下,MARa检测CAD的AUC为0.75(CI=0.60-0.86)。
  • MARf对CAD定位(所有血管)的AUC显著高于MARa或MARp或两者。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The effective non-invasive identification of coronary artery disease (CAD) and its proper referral for invasive treatment are still unresolved issues. We evaluated our quantification of myocardium at risk (MAR) from our second generation 3D MPI/CTA fusion framework for the detection and localization of obstructive coronary disease. METHODS: Studies from 48 patients who had rest/stress MPI, CTA, and ICA were analyzed from 3 different institutions. From the CTA, a 3D biventricular surface of the myocardium with superimposed coronaries was extracted and fused to the perfusion distribution. Significant lesions were identified from CTA readings and positioned on the fused display. Three estimates of MAR were computed on the 3D LV surface on the basis of the MPI alone (MARp), the CTA alone (MARa), and the fused information (MARf). The extents of areas at risk were used to generate ROC curves using ICA anatomical findings as reference standard. RESULTS: Areas under the ROC curve (AUC) for CAD detection using MARf was 0.88 (CI = 0.75-0.95) and for MARp and MARa were, respectively 0.82 (CI = 0.69-0.92) and 0.75 (CI = 0.60-0.86) using the ≥70% stenosis criterion. AUCs for CAD localization (all vessels) using MARf showed significantly higher performance than either MARa or MARp or both. CONCLUSIONS: Using ICA as the reference standard, MAR as the quantitative parameter, and AUC to measure diagnostic performance, MPI-CTA fusion imaging provided incremental diagnostic information compared to MPI or CTA alone for the diagnosis and localization of CAD.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Piccinelli M, Santana C, Sirineni GKR, et al. Diagnostic performance of the quantification of myocardium at risk from MPI SPECT/CTA 2G fusion for detecting obstructive coronary disease: A multicenter trial. J Nucl Cardiol. 2017. PMID: 28194728. doi:10.1007/s12350-017-0819-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。