文献速递肿瘤 PET/CT放射性药物与辐射防护

探讨SPECT/CT在阴茎癌动态前哨淋巴结活检中的作用

Investigating the role of SPECT/CT in dynamic sentinel lymph node biopsy for penile cancers.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2017-02-07

本研究对115例临床腹股沟淋巴结不可触及的阴茎癌患者行99mTc-纳米胶体注射后平面淋巴显像与SPECT/CT,比较两种方法检出的腹股沟淋巴结。平面显像与SPECT/CT分别识别440枚与467枚淋巴结,SPECT/CT在87例(76%)中发现明显差异,并识别平面显像误判的皮肤污染与淋巴管内活性。

要点

  • SPECT/CT在87/115例(76%)中与平面显像存在明显差异。
  • SPECT/CT识别平面显像误判为淋巴结的皮肤污染17处(16例,13%)和淋巴管内活性36处(24例,20%)。
  • SPECT/CT检出平面显像未显示的53枚示踪剂浓聚淋巴结(48例,42%),并重新分类27枚淋巴结的引流区。

核心结论

  • 加用SPECT/CT提高了真性示踪剂浓聚淋巴结的检出率,并精确勾画其在引流区的三维解剖定位。

研究设计与样本

  • 对115例连续患者(年龄28-86岁)行99mTc-纳米胶体注射后即刻动态(20分钟)和早期静态(5分钟)平面显像,并于120分钟行延迟静态(5分钟)平面显像后行SPECT/CT,对平面与SPECT/CT图像进行定性(视觉)比较。

主要发现

  • 平面显像与SPECT/CT分别识别440枚与467枚淋巴结。
  • SPECT/CT在28/115例(24%)中证实平面显像所见,在其余87例(76%)中观察到明显差异。
  • SPECT/CT识别平面显像误判为示踪剂浓聚淋巴结的皮肤污染17处(16例,13%)和淋巴管内活性36处(24例,20%)。
  • SPECT/CT检出平面显像未显示的53枚示踪剂浓聚淋巴结(48例,42%),并使27枚示踪剂浓聚淋巴结的引流区(盆腔/腹股沟)重新分类。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Currently, most centres use 2-D planar lymphoscintigraphy when performing dynamic sentinel lymph node biopsy in penile cancer patients with clinically impalpable inguinal nodes. This study aimed to investigate the role of SPECT/CT following 2-D planar lymphoscintigraphy (dynamic and static) in the detection and localization of sentinel lymph nodes in the groin. METHODS: A qualitative (visual) review was performed on planar followed by SPECT/CT lymphoscintigraphy in 115 consecutive patients (age 28-86 years) who underwent injection of 99mTc-nanocolloid followed by immediate acquisition of dynamic (20 min) and early static scans (5 min) initially and further delayed static (5 min) images at 120 min followed by SPECT/CT imaging. The lymph nodes detected in each groin on planar lymphoscintigraphy and SPECT/CT were compared. RESULTS: A total of 440 and 467 nodes were identified on planar scintigraphy and SPECT/CT, respectively. Overall, SPECT/CT confirmed the findings of planar imaging in 28/115 cases (24%). In the remaining 87 cases (76%), gross discrepancies were observed between planar and SPECT/CT images. SPECT/CT identified 17 instances of skin contamination (16 patients, 13%) and 36 instances of in-transit lymphatic tract activity (24 patients, 20%) that had been interpreted as tracer-avid lymph nodes on planar imaging. In addition, SPECT/CT identified 53 tracer-avid nodes in 48 patients (42%) that were not visualized on planar imaging and led to reclassification of the drainage basins (pelvic/inguinal) of 27 tracer-avid nodes. CONCLUSIONS: The addition of SPECT/CT improved the rate of detection of true tracer-avid lymph nodes and delineated their precise (3-D) anatomic localization in drainage basins.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Saad ZZ, Omorphos S, Michopoulou S, et al. Investigating the role of SPECT/CT in dynamic sentinel lymph node biopsy for penile cancers. Eur J Nucl Med Mol Imaging. 2017. PMID: 28175934. doi:10.1007/s00259-017-3636-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。