研究纳入48例前列腺癌患者,基于18F氟化钠PET/CT计算手动PET指数和自动PET15指数(阈值SUV 15),并与骨扫描指数(BSI)比较及分析其与总生存期(OS)的关联。BSI、手动PET指数和自动PET15指数均与OS显著相关,一致性指数分别为0.68、0.69和0.70。

要点

  • BSI、手动PET指数和自动PET15指数均与前列腺癌患者总生存期显著相关。
  • 手动PET指数中位值0.53,高于该值者中位生存2.5年,低于该值者5年随访未达中位。
  • 自动PET15指数中位值0.11,高于该值者中位生存2.3年,低于该值者5年随访未达中位。

核心结论

  • 基于18F氟化钠PET/CT的PET/CT指数与骨扫描指数相关,且与前列腺癌患者总生存期显著相关。

研究设计与样本

  • 研究纳入48例前列腺癌患者,对NaF PET/CT和骨扫描进行回顾性分析(原文未明确回顾性,照录为研究)。
  • 在CT图像上自动分割胸椎、腰椎、骶骨、骨盆、肋骨、肩胛骨、锁骨和胸骨。
  • 采用手动和自动两种方法选择PET图像中的热点。
  • 计算每个热点在对应CT图像骨骼中的体积,将全部热点体积之和除以全部骨体积得到手动PET指数和自动PET15指数(阈值SUV 15)。

主要发现

  • BSI、手动PET指数和自动PET15指数均与OS显著相关,一致性指数分别为0.68、0.69和0.70。
  • 中位BSI为0.39,BSI>0.39者中位生存时间2.3年,BSI<0.39者5年随访未达中位生存时间(p=0.01)。
  • 中位手动PET指数为0.53,手动PET指数>0.53者中位生存时间2.5年,手动PET指数<0.53者5年随访未达中位生存时间(p<0.001)。
  • 中位自动PET15指数为0.11,自动PET15指数>0.11者中位生存时间2.3年,自动PET15指数<0.11者5年随访未达中位生存时间(p<0.001)。

关键数值与推荐

  • 手动PET指数:全部热点体积之和除以全部骨体积。
  • 自动PET15指数:以SUV 15为阈值自动选择热点,计算方式同手动PET指数。
  • BSI通过自动计算软件获得。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Sodium fluoride (NaF) positron emission tomography combined with computer tomography (PET/CT) has shown to be more sensitive than the whole-body bone scan in the detection of skeletal uptake due to metastases in prostate cancer. We aimed to calculate a 3D index for NaF PET/CT and investigate its correlation to the bone scan index (BSI) and overall survival (OS) in a group of patients with prostate cancer. METHODS: NaF PET/CT and bone scans were studied in 48 patients with prostate cancer. Automated segmentation of the thoracic and lumbar spines, sacrum, pelvis, ribs, scapulae, clavicles, and sternum were made in the CT images. Hotspots in the PET images were selected using both a manual and an automated method. The volume of each hotspot localized in the skeleton in the corresponding CT image was calculated. Two PET/CT indices, based on manual (manual PET index) and automatic segmenting using a threshold of SUV 15 (automated PET15 index), were calculated by dividing the sum of all hotspot volumes with the volume of all segmented bones. BSI values were obtained using a software for automated calculations. RESULTS: BSI, manual PET index, and automated PET15 index were all significantly associated with OS and concordance indices were 0.68, 0.69, and 0.70, respectively. The median BSI was 0.39 and patients with a BSI >0.39 had a significantly shorter median survival time than patients with a BSI <0.39 (2.3 years vs not reached after 5 years of follow-up [p = 0.01]). The median manual PET index was 0.53 and patients with a manual PET index >0.53 had a significantly shorter median survival time than patients with a manual PET index <0.53 (2.5 years vs not reached after 5 years of follow-up [p < 0.001]). The median automated PET15 index was 0.11 and patients with an automated PET15 index >0.11 had a significantly shorter median survival time than patients with an automated PET15 index <0.11 (2.3 years vs not reached after 5 years of follow-up [p < 0.001]). CONCLUSIONS: PET/CT indices based on NaF PET/CT are correlated to BSI and significantly associated with overall survival in patients with prostate cancer.