标准化摄取值在注射18F-氟脱氧葡萄糖后不同时间反映肝脾FDG磷酸化程度的分析
本研究对60例注射FDG后60分钟行全身PET/CT的患者先行30分钟动态PET,用Patlak-Rutland分析测肝脾FDG清除率,计算不同血液清除半衰期下FDG6P/FDG比值并与SUV比较。结果显示肝脾SUV与Ki/V(0)相关性差,SUV主要由未磷酸化FDG决定。
要点
- 肝脏SUV比脾脏SUV高1.36倍,但脾脏Ki/V(0)均值高于肝脏。
- 注射后60分钟FDG磷酸化比例肝脏为23%–27%,脾脏为34%–39%(取决于假设血液清除半衰期)。
- 两器官SUV指标与Ki/V(0)相关性均差,SUV主要由与血液FDG动态交换的未磷酸化FDG决定。
核心结论
- SUV主要由与血液FDG动态交换的未磷酸化FDG决定,这解释了SUV指标与Ki/V(0)之间相关性差的原因。
研究设计与样本
- 60例患者注射FDG后60分钟行全身PET/CT,先行30分钟动态PET,采用Patlak-Rutland分析测量肝脏和脾脏FDG清除率。
- 以测得的Ki/V(0)值,在假设FDG血液消失半衰期为40、50和60分钟的条件下,计算两器官FDG6P/FDG比值随时间的变化。
- 肝脏和脾脏SUV从全身PET/CT测量。
主要发现
- 肝脏和脾脏Ki/V(0)均值(标准差)分别为0.0036(0.0021)和0.0060(0.0041)ml/min/ml。
- 肝脏SUV比脾脏SUV高1.36倍,该差异由肝脏V(0)比脾脏V(0)高1.6倍解释。
- 注射后60分钟FDG磷酸化百分比:肝脏在血液清除半衰期40、50、60分钟时分别为27%、25%、23%;脾脏分别为39%、36%、34%。
- 两器官SUV指标与Ki/V(0)相关性均差。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: In FDG PET/CT, standardized uptake value (SUV) is used to measure metabolic activity but detects un-phosphorylated FDG as well as phosphorylated FDG (FDG6P). Our aim was to determine the proportions of intrahepatic and intrasplenic FDG that are phosphorylated after FDG injection and compare them with SUVs. METHODS: Sixty patients undergoing whole-body PET/CT 60 min post-injection of FDG first had dynamic PET imaging for 30 min with measurement of hepatic and splenic FDG clearances using Patlak-Rutland analysis. The gradient of the Patlak-Rutland plot, which is proportional to clearance (Ki), was normalized to the intercept, which is proportional to FDG distribution volume (V(0)) with the same proportionality constant. Using measured values of Ki/V(0), FDG6P/FDG ratios as functions of time in the two organs were measured for assumed FDG blood disappearance half-times of 40, 50 and 60 min. Hepatic and splenic SUVs were measured from whole-body PET/CT. RESULTS: The mean (SD) Ki/V(0) was 0.0036 (0.0021) and 0.0060 (0.0041) ml/min/ml for the liver and spleen, respectively, but the hepatic SUV was 1.36-fold higher than the splenic SUV. This discrepancy was explained by the hepatic V(0) being 1.6-fold higher than the splenic V(0). The percentages of FDG phosphorylated 60 min post-injection were 27, 25 and 23% for the liver and 39, 36 and 34% for the spleen, for blood clearance half-times of 40, 50 and 60 min, respectively. SUV indices correlated poorly with Ki/V(0) for both organs. CONCLUSIONS: SUV is largely determined by un-phosphorylated FDG in dynamic exchange with blood FDG, explaining the poor correlations between SUV indices and Ki/V(0).
引用
- Keramida G, Anagnostopoulos CD, Peters AM, et al. The extent to which standardized uptake values reflect FDG phosphorylation in the liver and spleen as functions of time after injection of 18F-fluorodeoxyglucose. EJNMMI Res. 2017. PMID: 28176243. doi:10.1186/s13550-017-0254-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。