多位点68Ga-PSMA I&T PET/CT用于原发性前列腺癌表征:早期动态与延迟显像的价值
本研究纳入20例前列腺癌患者,在前列腺切除术前行68Ga-PSMA I&T PET/CT,包含早期盆腔动态显像及注射后60和180分钟静态扫描。结果显示95%患者原发肿瘤在动态和延迟显像上均可识别,肿瘤与良性前列腺组织的示踪剂摄取在所有时间点均显著更高(P ≤ 0.0003),腺体内肿瘤/非肿瘤比值随时间改善(10分钟2.8 vs 180分钟17.1)。
要点
- 95%患者原发肿瘤在早期动态和延迟显像上均可识别。
- 前列腺癌摄取在所有时间点显著高于良性组织(P ≤ 0.0003)。
- 腺体内肿瘤/非肿瘤比值随时间改善,支持延迟显像优化可视化。
核心结论
- 原发前列腺癌在早期动态和静态延迟68Ga-PSMA配体PET图像上易于识别。
- 前列腺腺体内肿瘤/非肿瘤比值随时间改善,支持延迟显像用于前列腺癌最佳可视化。
研究设计与样本
- 20例前列腺癌患者在前列腺切除术前接受68Ga-PSMA I&T PET/CT。
- PET方案包括早期盆腔动态显像,以及注射后60和180分钟静态扫描。
- 比较前列腺癌与良性前列腺组织的SUV、时间-活性曲线、基于二组织室模型的定量分析、Patlak分析、组织病理学和Gleason分级。
主要发现
- 95%患者原发肿瘤在早期动态和延迟显像上均可识别。
- 前列腺癌示踪剂摄取在所有时间点显著高于良性前列腺组织(P ≤ 0.0003),且随时间增加。
- 前列腺腺体内肿瘤/非肿瘤比值随时间改善(注射后10分钟2.8 vs 180分钟17.1)。
- 注射后60和180分钟示踪剂摄取在较高Gleason评分患者中显著更高(P < 0.01)。
- 前列腺癌流入速率(Ki)高于参考前列腺腺体(0.055 [r = 0.998] vs 0.017 [r = 0.996])。
关键数值与推荐
- 肿瘤/非肿瘤比值:注射后10分钟2.8 vs 180分钟17.1。
- 前列腺癌与良性组织摄取比较 P ≤ 0.0003。
- 较高Gleason评分患者摄取比较 P < 0.01。
- 流入速率Ki:前列腺癌0.055 [r = 0.998] vs 参考前列腺腺体0.017 [r = 0.996]。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: The aims of this study were to gain mechanistic insights into prostate cancer biology using dynamic imaging and to evaluate the usefulness of multiple time-point Ga-prostate-specific membrane antigen (PSMA) I&T PET/CT for the assessment of primary prostate cancer before prostatectomy. METHODS: Twenty patients with prostate cancer underwent Ga-PSMA I&T PET/CT before prostatectomy. The PET protocol consisted of early dynamic pelvic imaging, followed by static scans at 60 and 180 minutes postinjection (p.i.). SUVs, time-activity curves, quantitative analysis based on a 2-tissue compartment model, Patlak analysis, histopathology, and Gleason grading were compared between prostate cancer and benign prostate gland. RESULTS: Primary tumors were identified on both early dynamic and delayed imaging in 95% of patients. Tracer uptake was significantly higher in prostate cancer compared with benign prostate tissue at any time point (P ≤ 0.0003) and increased over time. Consequently, the tumor-to-nontumor ratio within the prostate gland improved over time (2.8 at 10 minutes vs 17.1 at 180 minutes p.i.). Tracer uptake at both 60 and 180 minutes p.i. was significantly higher in patients with higher Gleason scores (P < 0.01). The influx rate (Ki) was higher in prostate cancer than in reference prostate gland (0.055 [r = 0.998] vs 0.017 [r = 0.996]). CONCLUSIONS: Primary prostate cancer is readily identified on early dynamic and static delayed Ga-PSMA ligand PET images. The tumor-to-nontumor ratio in the prostate gland improves over time, supporting a role of delayed imaging for optimal visualization of prostate cancer.
引用
- Schmuck S, Mamach M, Wilke F, et al. Multiple Time-Point 68Ga-PSMA I&T PET/CT for Characterization of Primary Prostate Cancer: Value of Early Dynamic and Delayed Imaging. Clin Nucl Med. 2017. PMID: 28221194. doi:10.1097/RLU.0000000000001589
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。