同步心脏PET/MR的心脏与呼吸运动校正
研究在犬心肌梗死模型及一例人体中评估同步18F-FDG PET/MR自由呼吸三维MR数据经非刚性配准获得心脏与呼吸运动场,用于运动补偿MR与PET重建,5分钟内完成。运动校正在所有受试者改善MR图像质量,犬冠状动脉锐度提高85%±72%,左室射血分数与标准MR电影扫描差值为-2%±3%。
要点
- 自由呼吸三维MR数据经非刚性配准获得心脏与呼吸运动场,用于运动补偿MR和PET重建。
- 犬心肌FWHM改善13%±5%,心肌与血池对比噪声比较心脏门控高90%±57%。
- 运动校正使犬冠状动脉锐度提高85%±72%,射血分数与标准MR电影差值为-2%±3%。
核心结论
- 该MR技术可同时提供诊断信息与运动信息,用于改善MR和PET图像质量。
- 可靠的呼吸与心脏运动校正可使心脏PET结果更具可重复性。
研究设计与样本
- 研究采集自由呼吸三维MR数据并回顾性分箱为多个呼吸和心脏运动状态。
- 采用非刚性配准算法获得三维心脏和呼吸运动场并用于运动补偿MR和PET重建。
- 在犬心肌梗死模型同步18F-FDG PET/MR扫描中评估图像质量与诊断准确性改善,并在一例人体中展示。
主要发现
- MR运动场成功用于补偿在体心脏运动,犬心肌半高全宽改善13%±5%,与心脏门控相似但心肌与血池对比噪声比高90%±57%。
- 运动校正使所有受试者MR图像质量改善,犬冠状动脉锐度提高85%±72%。
- 功能评估显示与标准MR电影扫描吻合良好,射血分数差值为-2%±3%。
- 基于MR的呼吸与心脏运动信息用于改善一例人体在体扫描的PET图像质量。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Cardiac PET is a versatile imaging technique providing important diagnostic information about ischemic heart diseases. Respiratory and cardiac motion of the heart can strongly impair image quality and therefore diagnostic accuracy of cardiac PET scans. The aim of this study was to investigate a new cardiac PET/MR approach providing respiratory and cardiac motion-compensated MR and PET images in less than 5 min. Methods: Free-breathing 3-dimensional MR data were acquired and retrospectively binned into multiple respiratory and cardiac motion states. Three-dimensional cardiac and respiratory motion fields were obtained with a nonrigid registration algorithm and used in motion-compensated MR and PET reconstructions to improve image quality. The improvement in image quality and diagnostic accuracy of the technique was assessed in simultaneous 18F-FDG PET/MR scans of a canine model of myocardial infarct and was demonstrated in a human subject. Results: MR motion fields were successfully used to compensate for in vivo cardiac motion, leading to improvements in full width at half maximum of the canine myocardium of 13% ± 5%, similar to cardiac gating but with a 90% ± 57% higher contrast-to-noise ratio between myocardium and blood. Motion correction led to an improvement in MR image quality in all subjects, with an increase in sharpness of the canine coronary arteries of 85% ± 72%. A functional assessment showed good agreement with standard MR cine scans with a difference in ejection fraction of -2% ± 3%. MR-based respiratory and cardiac motion information was used to improve the PET image quality of a human in vivo scan. Conclusion: The MR technique presented here provides both diagnostic and motion information that can be used to improve MR and PET image quality. Reliable respiratory and cardiac motion correction could make cardiac PET results more reproducible.
引用
- Kolbitsch C, Ahlman MA, Davies-Venn C, et al. Cardiac and Respiratory Motion Correction for Simultaneous Cardiac PET/MR. J Nucl Med. 2017. PMID: 28183991. doi:10.2967/jnumed.115.171728
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。