文献速递肿瘤 PET/CT放射性药物与辐射防护

猪膀胱前哨淋巴结的荧光分子成像

Fluorescence-Based Molecular Imaging of Porcine Urinary Bladder Sentinel Lymph Nodes.
PubMed 文献 · J Nucl Med · 2017-02-02

研究在3头雌猪膀胱黏膜下注射同时标记68Ga和99mTc的荧光tilmanocept,1小时后行盆腔PET/CT前哨淋巴结定位,约36小时后用荧光腹腔镜系统行机器人前哨淋巴结定位并完成盆腔淋巴结清扫。离体γ计数确认的前哨淋巴结均被荧光模式检出,共检出5枚荧光淋巴结。

要点

  • 荧光标记的68Ga-tilmanocept可实现PET成像和机器人手术中前哨淋巴结实时检测。
  • 离体γ计数确认的前哨淋巴结均被荧光模式成像检出。
  • 注射至机器人定位时间32-38小时,5枚前哨淋巴结中4枚PET/CT SUV升高12.4-139.0。

核心结论

  • 荧光标记的68Ga-tilmanocept可用于PET成像及机器人手术中前哨淋巴结的实时术中检测。

研究设计与样本

  • 研究纳入3头雌猪,膀胱黏膜下注射同时标记68Ga和99mTc的荧光tilmanocept。
  • 注射后1小时行盆腔PET/CT术前前哨淋巴结定位,约36小时后用荧光腹腔镜系统行机器人前哨淋巴结定位。
  • 识别荧光淋巴结后行机器人辅助盆腔淋巴结清扫,共切除36个淋巴结包并检测99mTc活性以判定前哨淋巴结。

主要发现

  • 离体γ计数确认的所有前哨淋巴结均被荧光模式成像检出。
  • 注射至机器人前哨淋巴结定位时间为32至38小时。
  • 共检出5枚荧光淋巴结,其中2头猪各2枚、1头猪1枚。
  • 5枚前哨淋巴结中4枚PET/CT SUV升高,范围为12.4至139.0。
  • 注射部位染料量为371至1441 pmol,占注射剂量的16.5%至64.1%;前哨淋巴结内染料量为8.5至88 pmol,占给药剂量的0.38%至3.91%。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

The primary objective was to test the ability of a laparoscopic camera system to detect the fluorescent signal emanating from sentinel lymph nodes (SLNs) approximately 2 d after injection and imaging of a positron-emitting molecular imaging agent into the submucosa of the porcine urinary bladder. Methods: Three female pigs underwent a submucosal injection of the bladder with fluorescent-tagged tilmanocept, radiolabeled with both 68Ga and 99mTc. One hour after injection, a pelvic PET/CT scan was acquired for preoperative SLN mapping. Approximately 36 h later, robotic SLN mapping was performed using a fluorescence-capable camera system. After identification of the fluorescent lymph nodes, a pelvic lymph node dissection was completed with robotic assistance. All excised nodal packets (n = 36) were assayed for 99mTc activity, which established a lymph node as an SLN. 99mTc activity was also used to calculate the amount of dye within each lymph node. Results: All of the SLNs defined by the ex vivo γ-well assay of 99mTc activity were detected by fluorescence mode imaging. The time between injection and robotic SLN mapping ranged from 32 to 38 h. A total of 5 fluorescent lymph nodes were detected; 2 pigs had 2 fluorescent lymph nodes and 1 pig exhibited a single lymph node. Four of the 5 SLNs exhibited increased SUVs of 12.4-139.0 obtained from PET/CT. The dye content of the injection sites ranged from 371 to 1,441 pmol, which represented 16.5%-64.1% of the injected dose; the amount of dye within the SLNs ranged from 8.5 to 88 pmol, which was equivalent to 0.38%-3.91% of the administered dose. Conclusion: Fluorescent-labeled 68Ga-tilmanocept allows for PET imaging and real-time intraoperative detection of SLNs during robotic surgery.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Lee HJ, Barback CV, Hoh CK, et al. Fluorescence-Based Molecular Imaging of Porcine Urinary Bladder Sentinel Lymph Nodes. J Nucl Med. 2017. PMID: 28153955. doi:10.2967/jnumed.116.178582

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。