18F-FDG PET/CT 与 MRI 在抗体特异性自身免疫性脑炎中的诊断价值
该回顾性研究评估了23例抗体阳性自身免疫性脑炎患者初始检查中MRI与18F-FDG PET/CT的阳性率,结果显示18F-FDG PET/CT在诊断期异常率高于MRI(10/23,43%),且全部患者视觉分析均见异常摄取模式,以脑叶低代谢为主(21/23,91.3%)。
要点
- 18F-FDG PET/CT视觉分析全部23例均显示异常摄取模式。
- 半定量分析中22/23(95.6%)患者至少一个感兴趣区存在代谢改变(z评分2)。
- 诊断期18F-FDG PET/CT异常率高于MRI(10/23,43%),主要表现脑叶低代谢(21/23,91.3%)。
核心结论
- 脑18F-FDG PET/CT可能在临床疑似抗体介导自身免疫性脑炎的初始评估中起重要作用。
- 由于在急性期较MRI更常显示异常,该分子影像技术可能更适合作为疾病的早期生物标志物,以便更早启动治疗、改善患者结局。
研究设计与样本
- 回顾性研究,评估23例经证实为抗体阳性自身免疫性脑炎患者初始检查中MRI与18F-FDG PET/CT的阳性率。
- 18F-FDG PET/CT图像进行定性及半定量分析,大脑皮层脑叶低(高)代谢区域偏离均值2个标准差记录为异常。
主要发现
- 视觉分析全部患者均被识别为18F-FDG摄取模式异常。
- 半定量分析中,采用判别z评分2时,23例中22例(95.6%)至少一个感兴趣区存在代谢改变。
- 诊断期18F-FDG PET/CT较MRI更常异常(10/23,43%的患者)。
- 脑18F-FDG PET/CT主要发现为脑叶低代谢,见于23例中21例(91.3%),最常见于顶叶,其次为枕叶。
- 抗N-甲基-D-天冬氨酸受体(anti-NMDAR)抗体阳性患者(5例)MRI结果正常而18F-FDG PET/CT异常,其他抗体亚组表现更异质。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
Diagnosis of autoimmune encephalitis presents some challenges in the clinical setting because of varied clinical presentations and delay in obtaining antibody panel results. We examined the role of neuroimaging in the setting of autoimmune encephalitides, comparing the utility of 18F-FDG PET/CT versus conventional brain imaging with MRI. Methods: A retrospective study was performed assessing the positivity rate of MRI versus 18F-FDG PET/CT during the initial workup of 23 patients proven to have antibody-positive autoimmune encephalitis. 18F-FDG PET/CT studies were analyzed both qualitatively and semiquantitatively. Areas of cortical lobar hypo (hyper)-metabolism in the cerebrum that were 2 SDx from the mean were recorded as abnormal. Results: On visual inspection, all patients were identified as having an abnormal pattern of 18F-FDG uptake. In semiquantitative analysis, at least 1 region of interest with metabolic change was identified in 22 of 23 (95.6%) patients using a discriminating z score of 2. Overall, 18F-FDG PET/CT was more often abnormal during the diagnostic period than MRI (10/23, 43% of patients). The predominant finding on brain 18F-FDG PET/CT imaging was lobar hypometabolism, being observed in 21 of 23 (91.3%) patients. Hypometabolism was most commonly observed in the parietal lobe followed by the occipital lobe. An entire subset of antibody-positive patients, anti-N-methyl-d-aspartate receptor (5 patients), had normal MRI results and abnormal 18F-FDG PET/CT findings whereas the other subsets demonstrated a greater heterogeneity. Conclusion: Brain 18F-FDG PET/CT may play a significant role in the initial evaluation of patients with clinically suspected antibody-mediated autoimmune encephalitis. Given that it is more often abnormal when compared with MRI in the acute setting, this molecular imaging technique may be better positioned as an early biomarker of disease so that treatment may be initiated earlier, resulting in improved patient outcomes.
引用
- Solnes LB, Jones KM, Rowe SP, et al. Diagnostic Value of 18F-FDG PET/CT Versus MRI in the Setting of Antibody-Specific Autoimmune Encephalitis. J Nucl Med. 2017. PMID: 28209905. doi:10.2967/jnumed.116.184333
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。