通过SPECT心肌灌注显像测量的左心室偏心指数:心脏不良重构的附加参数
本研究在456例接受碲锌镉(CZT)相机心肌灌注显像的患者中评估左心室偏心指数(EI)测量的可行性及其与左心室功能和结构参数的关系。结果显示EI在CZT图像上可重复性极佳(组内相关系数0.99,95%CI 0.98-0.99),EI异常与更差的灌注、功能和结构相关,较高舒张末期容积(P<.001)和较低射血分数(P=.014)是EI异常的独立预测因素。
要点
- 在CZT门控图像上测量左心室偏心指数可行,可重复性极佳(组内相关系数0.99,95%CI 0.98-0.99)。
- EI异常与左心室灌注、功能(EF和PFR)及结构(EDV)异常相关(P<.001)。
- 较高EDV(P<.001)和较低EF(P=.014)是EI异常的独立预测因素。
核心结论
- 在门控CZT图像上评估左心室偏心性是可行的。
- 异常EI与显著的心脏结构和功能异常相关。
研究设计与样本
- 共456例患者接受碲锌镉(CZT)相机心肌灌注显像。
- 计算静息、负荷和差值总评分,并从静息图像计算左心室舒张末期容积、收缩末期容积、射血分数和峰值充盈率。
- 使用专用软件(QGS/QPS;Cedars-Sinai Medical Center)计算每位患者的EI,范围从0(球形)到1(线形)。
主要发现
- 338/456(74%)患者射血分数正常(>50%),26%患者存在左心室收缩功能障碍。
- EI在CZT图像上的可重复性极佳(组内相关系数0.99,95%CI 0.98-0.99)。
- 更受损的EI值与更异常的左心室灌注(P<.001)、功能(EF和PFR,P<.001)及结构(EDV,P<.001)相关。
- 多因素分析中,较高EDV(P<.001)和较低EF(P=.014)是EI异常的独立预测因素。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Single-photon emission computed-tomography (SPECT) allows the quantification of LV eccentricity index (EI), a measure of cardiac remodeling. We sought to evaluate the feasibility of EI measurement with SPECT myocardial perfusion imaging and its interactions with relevant LV functional and structural parameters. METHODS AND RESULTS: Four-hundred and fifty-six patients underwent myocardial perfusion imaging on a Cadmium-Zinc-Telluride (CZT) camera. The summed rest, stress, and difference scores were calculated. From rest images, the LV end-diastolic (EDV) and end-systolic volumes, ejection fraction (EF), and peak filling rate (PFR) were calculated. In every patient, the EI, ranging from 0 (sphere) to 1 (line), was computed using a dedicated software (QGS/QPS; Cedars-Sinai Medical Center). Three-hundred and thirty-eight/456 (74%) patients showed a normal EF (>50%), while 26% had LV systolic dysfunction. The EI was computed from CZT images with excellent reproducibility (interclass correlation coefficient: 0.99, 95% CI 0.98-0.99). More impaired EI values correlated with the presence of a more abnormal LV perfusion (P < .001), function (EF and PFR, P < .001), and structure (EDV, P < .001). On multivariate analysis, higher EDV (P < .001) and depressed EF (P = .014) values were independent predictors of abnormal EI. CONCLUSIONS: The evaluation of LV eccentricity is feasible on gated CZT images. Abnormal EI associates with significant cardiac structural and functional abnormalities.
引用
- Gimelli A, Liga R, Clemente A, et al. Left ventricular eccentricity index measured with SPECT myocardial perfusion imaging: An additional parameter of adverse cardiac remodeling. J Nucl Cardiol. 2017. PMID: 28083831. doi:10.1007/s12350-017-0777-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。