使用IQ·SPECT系统创建并表征正常心肌灌注成像数据库
本研究回顾性纳入日本四家医院的159例冠心病低可能性患者,行短时201Tl心肌灌注IQ·SPECT显像,分别建立仰卧位、俯卧位及仰卧位联合衰减散射校正(ACSC)的正常数据库,并比较心肌灌注分布差异。结果显示未校正仰卧位与俯卧位数据库、未校正仰卧位与ACSC数据库、未校正仰卧位与常规SPECT数据库之间均存在显著差异。
要点
- 建立了短时201Tl IQ·SPECT仰卧位、俯卧位及仰卧位ACSC三个正常数据库。
- 未校正仰卧位与俯卧位数据库在中下侧壁计数存在显著差异。
- IQ·SPECT与常规SPECT数据库在中前壁、下侧壁及心尖侧壁计数存在显著差异。
核心结论
- 未校正仰卧位与俯卧位正常数据库、未校正仰卧位与仰卧位ACSC正常数据库、未校正仰卧位与常规SPECT正常数据库之间均存在显著差异。
- 理解IQ·SPECT短时采集有无ACSC的正常分布模式有助于解读冠状动脉疾病(CAD)或CAD低可能性患者的影像表现,且正常数据库有助于定量分析。
研究设计与样本
- 回顾性纳入日本四家医院的159例心脏病低可能性患者。
- 所有患者行短时201Tl心肌灌注IQ·SPECT,采集条件为仰卧位或俯卧位,伴或不伴衰减散射校正(ACSC)。
- 采用17节段极图计算平均心肌计数,分别从仰卧位、俯卧位及仰卧位ACSC图像衍生三个正常数据库。
主要发现
- 未校正性别分层正常数据库中,仰卧位与俯卧位在中下侧壁计数存在差异(男性p ≤ 0.016,女性p ≤ 0.002)。
- IQ·SPECT与常规SPECT在中前壁、下侧壁及心尖侧壁计数存在差异(男性p ≤ 0.009,女性p ≤ 0.003)。
- 仰卧位IQ·SPECT ACSC正常数据库在心尖前壁及心尖节段可见因心肌变薄所致的心尖低计数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Image acquisition by short-time single-photon emission-computed tomography (SPECT) has been made feasible by IQ·SPECT. The aim of this study was to generate normal databases (NDBs) of thallium-201 (201Tl) myocardial perfusion imaging for IQ·SPECT, and characterize myocardial perfusion distribution. METHODS AND RESULTS: We retrospectively enrolled 159 patients with a low likelihood of cardiac diseases from four hospitals in Japan. All patients underwent short-time 201Tl myocardial perfusion IQ·SPECT with or without attenuation and scatter correction (ACSC) in either supine or prone position. The mean myocardial counts were calculated using 17-segment polar maps. Three NDBs were derived from supine and prone images as well as supine images with ACSC. Differences between the supine and prone positions were observed in the uncorrected sex-segregated NDBs in the mid-inferolateral counts (p ≤ 0.016 for males and p ≤ 0.002 for females). Differences between IQ·SPECT and conventional SPECT were also observed in the mid-anterior, inferolateral, and apical lateral counts (p ≤ 0.009 for males and p ≤ 0.003 for females). Apical low counts attributed to myocardial thinning were observed in the apical anterior and apex segments in the supine IQ·SPECT NDB with ACSC. CONCLUSIONS: There were significant differences between uncorrected supine and prone NDBs, between uncorrected supine NDB and supine NDB with ACSC, and between uncorrected supine NDB and conventional SPECT NDB. Understanding the pattern of normal distribution in IQ-SPECT short-time acquisitions with and without ACSC will be helpful for interpretation of imaging findings in patients with coronary artery disease (CAD) or low likelihood of CAD and the NDBs will aid in quantitative analysis.
引用
- Okuda K, Nakajima K, Matsuo S, et al. Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system. J Nucl Cardiol. 2017. PMID: 28050865. doi:10.1007/s12350-016-0770-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。