文献速递肿瘤 PET/CT

2-18F-氟乙醇是实体瘤灌注的PET报告探针

2-18F-Fluoroethanol Is a PET Reporter of Solid Tumor Perfusion.
PubMed 文献 · J Nucl Med · 2017-01-26

本研究在4T1和67NR小鼠乳腺癌模型中,用离体放射自显影及静态、动态PET测量2-18F-氟乙醇摄取,并与14C-碘安替比林灌注报告探针直接比较,同时用烟酰胺、己酮可可碱和肼屈嗪调控肿瘤灌注。结果显示2-18F-氟乙醇摄取与已知肿瘤灌注差异一致,与14C-碘安替比林对应良好,并反映各药物的灌注调控效应。

要点

  • 2-18F-氟乙醇在4T1和67NR肿瘤中的摄取与已知灌注差异一致。
  • 2-18F-氟乙醇摄取与14C-碘安替比林对应良好。
  • 2-18F-氟乙醇反映烟酰胺、己酮可可碱和肼屈嗪的灌注调控效应。

核心结论

  • 2-18F-氟乙醇是一种新型18F基放射性示踪剂,可用于PET成像研究肿瘤灌注。
  • 定量2-18F-氟乙醇摄取可用于区分不同灌注水平的肿瘤,并筛选血流调控药物作为现有癌症治疗的辅助手段。

研究设计与样本

  • 在接种4T1和67NR小鼠乳腺癌的荷瘤小鼠中,用离体放射自显影及静态和动态PET测量2-18F-氟乙醇摄取。
  • 将2-18F-氟乙醇摄取与14C-碘安替比林灌注报告探针直接比较。
  • 在2-18F-氟乙醇定量前使用烟酰胺、己酮可可碱和肼屈嗪调控肿瘤灌注。

主要发现

  • 2-18F-氟乙醇在4T1和67NR肿瘤中的摄取与这些肿瘤内部及彼此之间已知的灌注差异一致。
  • 2-18F-氟乙醇摄取与14C-碘安替比林对应良好。
  • 2-18F-氟乙醇摄取反映了每种药物对肿瘤灌注的调控效应。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Solid tumor perfusion is a proven variable of interest for predicting cancer aggression and response to therapy. Current methods for noninvasively imaging tumor perfusion with PET are limited by restricted accessibility and short half-lives of perfusion radiotracers. This study presents 2-18F-fluoroethanol (2-18F-FEtOH) as a perfusion reporter that can distinguish between tumors of varying perfusion levels and can be applied to screening drugs that modify tumor perfusion. Methods: Uptake of 2-18F-FEtOH in 4T1 and 67NR murine mammary carcinoma tumors grown in mice was measured using ex vivo radiography as well as static and dynamic PET imaging. 2-18F-FEtOH uptake was directly compared with the 14C-iodoantipyrine perfusion reporter, and the perfusion-modifying drugs nicotinamide, pentoxifylline, and hydralazine were used to manipulate tumor perfusion before 2-18F-FEtOH quantification. Results: Uptake of 2-18F-FEtOH in 4T1 and 67NR tumors was consistent with known perfusion differences within and between these tumors. 2-18F-FEtOH uptake corresponded well with 14C-iodoantipyrine and reflected the tumor perfusion-modifying effects of each drug. Conclusion: 2-18F-FEtOH is a novel 18F-based radiotracer for investigating tumor perfusion with PET imaging. Quantification of 2-18F-FEtOH uptake can be used to distinguish between tumors of varying perfusion and to screen the efficacy of blood flow-modifying drugs for use as adjuvants to existing cancer therapies.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Wadsworth BJ, Pan J, Dude I, et al. 2-18F-Fluoroethanol Is a PET Reporter of Solid Tumor Perfusion. J Nucl Med. 2017. PMID: 28126891. doi:10.2967/jnumed.116.183624

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。