文献速递心脏核医学

双嘧达莫负荷下左心室功能反应:82铷PET与99mTc-甲氧基异丁基异腈SPECT心电门控心肌灌注显像的头对头比较

Left ventricular function in response to dipyridamole stress: head-to-head comparison between 82Rubidium PET and 99mTc-sestamibi SPECT ECG-gated myocardial perfusion imaging.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2016-12-16

研究纳入221例连续患者,在单次双嘧达莫负荷后先后行99mTc-甲氧基异丁基异腈(sestamibi)SPECT与82铷(82Rb)PET心肌灌注显像,比较左心室容积与左心室射血分数(LVEF)。Bland-Altman分析显示随舒张末期容积(EDV)和收缩末期容积(ESV)增大,两种示踪剂间容积差值在静息和负荷后均增大;但LVEF差值在负荷后无显著趋势,静息时仅随LVEF升高呈轻度线性增加。作者认为临床比较两种显像的功能参数时应考虑这些差异。

要点

  • 随EDV和ESV增大,sestamibi与82Rb间容积差值在静息和负荷后均增大。
  • 两种示踪剂间LVEF差值在负荷后无显著趋势(R2=0.001,p=0.70)。
  • 静息时LVEF差值仅随LVEF升高呈轻度线性增加(R2=0.032,p=0.009)。

核心结论

  • sestamibi与82Rb心肌灌注显像间左心室容积差值随容积增大而增大,但对LVEF仅有边际影响;临床比较两种显像的功能衍生参数时应考虑这些结果。

研究设计与样本

  • 研究纳入221例连续患者(65.2±10.4岁,52.9%为男性),在单次双嘧达莫负荷后先后行sestamibi SPECT与82Rb PET心肌灌注显像,比较静息、负荷及差值灌注评分与左心室功能参数。

主要发现

  • Bland-Altman分析显示,随ESV和EDV增大,两种灌注示踪剂间差值在静息和负荷后均增大。
  • 静息时两种示踪剂间EDV和ESV的平均差值均可分别由82Rb的SDS和sestamibi的SRS独立解释,联合模型分别解释约30%的容积变异(EDV:R2=0.261,p=0.005;ESV:R2=0.296,p<0.001)。
  • sestamibi与82Rb间LVEF平均差值在负荷后无显著趋势(R2=0.001,p=0.70),静息时仅随LVEF值升高呈轻度线性增加(R2=0.032,p=0.009)。

临床怎么用

  • 作者认为,临床实践中比较sestamibi与82Rb心肌灌注显像的功能衍生参数时,应考虑上述容积差值随容积增大而增大的结果。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Myocardial perfusion imaging (MPI) with 99mTc-sestamibi (sestamibi) SPECT and rubidium-82 (82Rb) PET both allow for combined assessment of perfusion and left ventricular (LV) function. We sought to compare parameters of LV function obtained with both methods using a single dipyridamole stress dose. MATERIALS AND METHODS: A group of 221 consecutive patients (65.2 ± 10.4 years, 52.9% male) underwent consecutive sestamibi and 82Rb MPI after a single dipyridamole stress dose. Sestamibi and 82Rb summed rest (SRS), stress (SSS) and difference (SDS) scores, and LV end-diastolic (EDV) and end-systolic (ESV) volumes and left ventricular ejection fraction (LVEF) were compared. RESULTS: Bland-Altman analysis showed that with increasing ESV and EDV the difference between the two perfusion tracers increased both at rest and post-stress. The mean difference in EDV and ESV between the two perfusion tracers at rest could both be independently explained by the 82Rb SDS and the sestamibi SRS. The combined models explained approximately 30% of the variation in these volumes between the two perfusion tracers (R2 = 0.261, p = 0.005; R2 = 0.296, p < 0.001, for EDV and ESV respectively). However, the mean difference in LVEF between sestamibi and 82Rb showed no significant trend post-stress (R2 = 0.001, p = 0.70) and only a modest linear increase with increasing LVEF values at rest (R2 = 0.032, p = 0.009). CONCLUSIONS: Differences in left ventricular volumes between sestamibi and 82Rb MPI increase with increasing volumes. However, these differences did only marginally affect LVEF between sestamibi and 82Rb. In clinical practice these results should be taken into account when comparing functional derived parameters between sestamibi and 82Rb MPI.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Giorgi MC, Meneghetti JC, Soares J, et al. Left ventricular function in response to dipyridamole stress: head-to-head comparison between 82Rubidium PET and 99mTc-sestamibi SPECT ECG-gated myocardial perfusion imaging. Eur J Nucl Med Mol Imaging. 2016. PMID: 27987028. doi:10.1007/s00259-016-3588-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。