文献速递心脏核医学

13N-氨PET/CT检测比格犬局部心脏照射后心肌灌注异常

13N-Ammonia PET/CT Detection of Myocardial Perfusion Abnormalities in Beagle Dogs After Local Heart Irradiation.
PubMed 文献 · J Nucl Med · 2016-12-01

研究将36只比格犬随机分为对照组(n=18)和照射组(n=18),照射组左心室前壁接受单次20 Gy局部照射。所有犬在照射前1周及照射后3、6、12个月行13N-氨PET/CT心肌灌注显像,照射组于显像后1周行冠状动脉造影。结果显示照射组照射区灌注在3个月时显著增高、6个月时减低、12个月时出现灌注缺损,且6个月和12个月左心室射血分数较对照组降低。

要点

  • 照射组照射区心肌灌注在3个月时显著增高、6个月时减低、12个月时出现灌注缺损。
  • 照射组左心室射血分数在6个月和12个月较对照组降低,基线及3个月时无显著差异。
  • 照射组未见冠状动脉狭窄,但6个月出现照射区室壁运动异常并于12个月范围扩大。

核心结论

  • 13N-氨PET/CT心肌灌注显像可动态检测照射引起的心肌灌注变化及整体与局部左心室功能障碍,可能是监测放射性心脏病的有价值方法。

研究设计与样本

  • 研究将36只比格犬随机分为对照组(n=18)和照射组(n=18),照射组左心室前壁接受单次20 Gy局部照射,对照组接受假照射。
  • 所有犬在照射前1周及照射后3、6、12个月行13N-氨PET/CT心肌灌注显像。
  • 照射组于13N-氨PET/CT心肌灌注显像后1周行冠状动脉造影。
  • 每组随机选取6只犬在照射后3、6、12个月处死,用于检测病理性心脏损伤。

主要发现

  • 与对照组和基线相比,照射组照射区心肌灌注在照射后3个月显著增高、6个月减低、12个月出现灌注缺损。
  • 基线及照射后3个月,对照组与照射组左心室射血分数无显著差异。
  • 照射后6个月,照射组左心室射血分数较对照组降低(50.0% ± 8.1% vs. 59.3% ± 4.1%,P = 0.016)。
  • 照射后12个月,照射组左心室射血分数较对照组降低(47.2% ± 6.7% vs. 57.4% ± 3.3%,P = 0.002)。
  • 照射组未见冠状动脉狭窄;照射后6个月照射区出现室壁运动异常,12个月范围扩大;照射区放射性心肌组织损伤及微血管纤维化随时间进展加重。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Our objective was to determine the potential value of 13N-ammonia PET/CT myocardial perfusion imaging (MPI) for early detection of myocardial perfusion changes induced by radiation damage. Methods: Thirty-six Beagle dogs were randomly divided into a control group (n = 18) or an irradiation group (n = 18). The latter underwent local irradiation to the left ventricular anterior cardiac wall with a single dose of 20 Gy, whereas the former received sham irradiation. All dogs underwent 13N-ammonia PET/CT MPI 1 wk before irradiation and at 3, 6, and 12 mo after sham or local irradiation. One week after undergoing 13N-ammonia PET/CT MPI, the irradiation group underwent coronary angiography. Six randomly selected dogs from each group were sacrificed and used to detect pathologic cardiac injury at 3, 6, and 12 mo after irradiation. Results: Compared with the control group and baseline, the irradiation group showed significantly increased perfusion in the irradiated area of the heart at 3 mo after irradiation, perfusion reduction at 6 mo after irradiation, and a perfusion defect at 12 mo after irradiation. There was no significant difference in the left ventricular ejection fraction between the control and irradiation groups at baseline or at 3 mo after irradiation. The irradiation group showed a reduction of left ventricular ejection fraction compared with the control group at 6 mo (50.0% ± 8.1% vs. 59.3% ± 4.1%, P = 0.016) and 12 mo (47.2% ± 6.7% vs. 57.4% ± 3.3%, P = 0.002) after irradiation. No coronary stenosis was observed in the irradiation group. Regional wall motion abnormalities appeared in the irradiated area at 6 mo after irradiation, and its extent was enlarged at 12 mo after irradiation. Pathologic changes were observed; radiation-induced myocardial tissue damage and microvascular fibrosis in the irradiated area progressively increased over time. Conclusion:13N-ammonia PET/CT MPI can dynamically detect myocardial perfusion changes together with global and regional left ventricular dysfunction induced by irradiation and may be a valuable method for monitoring radiation-induced heart disease.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Song J, Yan R, Wu Z, et al. 13N-Ammonia PET/CT Detection of Myocardial Perfusion Abnormalities in Beagle Dogs After Local Heart Irradiation. J Nucl Med. 2016. PMID: 27908971. doi:10.2967/jnumed.116.179697

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。