18F-flurpiridaz PET心肌灌注显像中短暂性缺血性扩张阈值的建立

Transient ischemic dilation with 18F-flurpiridaz positron emission tomography: Establishing thresholds for a novel radiotracer.
PubMed 文献 · J Nucl Cardiol · 2026-07-11

本研究为flurpiridaz-301多中心III期试验的二次分析,在746例有可评估PET、SPECT和冠状动脉造影数据的疑似冠心病患者中,建立了18F-flurpiridaz PET的应激方式特异性短暂性缺血性扩张(TID)参考阈值。运动负荷下TID阈值(97.5百分位)为1.18,药物负荷下为1.25(5-mm高斯滤波)。PET来源的TID值随冠状动脉病变严重程度增加而升高,且受应激方式和重建后滤波影响。

要点

  • 18F-flurpiridaz PET的TID参考阈值:运动负荷1.18,药物负荷1.25(5-mm高斯滤波)。
  • PET来源的TID值高于Tc-99m SPECT,且随冠状动脉病变严重程度增加而升高。
  • 重建后高斯滤波可降低PET来源的TID值,5-mm与8-mm滤波间差异不大。

核心结论

  • 本研究提出18F-flurpiridaz PET的应激方式特异性TID参考阈值,强调示踪剂、应激方式和协议特异性参考标准对TID临床解读的重要性。

研究设计与样本

  • 对多中心III期flurpiridaz-301试验进行二次分析,纳入疑似冠心病患者,均行静息-负荷18F-flurpiridaz PET、Tc-99m SPECT心肌灌注显像和侵入性冠状动脉造影。
  • 在无血管造影性冠心病的患者中推导应激方式特异性参考阈值,并评估应激方式、冠心病严重程度和重建后高斯滤波对TID测量的影响。

主要发现

  • 在746例有可评估PET、SPECT和血管造影数据的患者中,使用5-mm高斯滤波的18F-flurpiridaz PET应激方式特异性TID参考阈值(97.5百分位)为运动负荷1.18、药物负荷1.25。
  • 相应的Tc-99m SPECT阈值较低。
  • PET来源的TID值随血管造影定义的冠心病严重程度增加而逐渐升高,呈现跨疾病类别的分级关联。
  • 应用重建后高斯滤波导致PET来源的TID值低于未滤波图像,5-mm与8-mm滤波器之间差异不大。

关键数值与推荐

  • 18F-flurpiridaz PET使用5-mm高斯滤波时,运动负荷TID参考阈值(97.5百分位)为1.18。
  • 18F-flurpiridaz PET使用5-mm高斯滤波时,药物负荷TID参考阈值(97.5百分位)为1.25。
  • Tc-99m SPECT的相应TID阈值低于18F-flurpiridaz PET。

临床怎么用

  • 临床解读18F-flurpiridaz PET的TID时应采用示踪剂、应激方式和重建协议特异性参考标准,运动负荷与药物负荷阈值不同。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Transient ischemic dilation (TID) of the left ventricule (LV) is a specific marker of extensive coronary artery disease (CAD). Normal limits for TID using 18F-flurpiridaz have not been established. METHODS: We performed a secondary analysis of the multicenter phase III flurpiridaz-301 trial, which included patients with suspected CAD who underwent rest-stress 18F-flurpiridaz positron emission tomography (PET), Tc-99m single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI), and invasive coronary angiography (ICA). TID was calculated using ungated left ventricular volumes. Stress-specific reference thresholds were derived in patients without angiographic CAD. The effects of stress modality, CAD severity, and postreconstruction Gaussian filtering on TID measurements were evaluated. RESULTS: Among 746 patients with evaluable PET, SPECT, and angiographic data, stress-specific TID reference thresholds (97.5th percentile) for 18F-flurpiridaz PET using a 5-mm Gaussian filter were 1.18 for exercise stress and 1.25 for pharmacologic stress. Corresponding Tc-99m SPECT thresholds were lower. PET-derived TID values increased progressively with angiographically defined CAD severity, demonstrating a graded association across disease categories. Application of post-reconstruction Gaussian filtering resulted in lower PET-derived TID values compared with unfiltered images, with modest differences between 5-mm and 8-mm filters. CONCLUSIONS: This study suggests stress-specific reference thresholds for TID using 18F-flurpiridaz PET in a large multicenter cohort. PET-derived TID values were higher than those observed with Tc-99m SPECT, varied by stress modality, and were influenced by postreconstruction filtering. These findings highlight the importance of tracer-, stress-, and protocol-specific reference standards for accurate clinical interpretation of TID.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。