定量肺灌注SPECT/CT对双侧肺移植后慢性肺移植物功能障碍的诊断价值

Diagnostic Value of Quantitative Lung Perfusion Single-photon Emission CT/CT for Chronic Lung Allograft Dysfunction in Patients After Bilateral Lung Transplantation.
PubMed 文献 · Clin Nucl Med · 2026-06-17

本研究回顾性纳入80例接受SPECT/CT的肺移植受者,计算SUVmean、TLU和%ID,分析其区分CLAD与非CLAD肺的能力及与肺功能的相关性。结果示SUVmean无显著差异(P=0.250),TLU和%ID在CLAD中显著降低(P<0.0001);%ID曲线下面积0.78,以0.83为截断值灵敏度65.0%、特异度83.8%,为CLAD评估的有用无创指标。

要点

  • TLU和%ID在CLAD中显著低于非CLAD(P<0.0001),SUVmean无显著差异。
  • %ID诊断准确性最佳(AUC 0.78),截断值0.83时灵敏度65.0%、特异度83.8%。
  • 基于容积的定量肺灌注SPECT/CT参数可作为CLAD的无创评估指标。

核心结论

  • 基于容积的定量指标尤其是%ID可作为评估慢性肺移植物功能障碍的有用无创指标。

研究设计与样本

  • 回顾性研究纳入80例接受SPECT/CT的肺移植受者,计算SUVmean、TLU和%ID,分析组间差异、ROC性能及与肺功能的相关性。

主要发现

  • SUVmean在CLAD与非CLAD间无显著差异(P=0.250)。
  • TLU和%ID在CLAD中显著低于非CLAD(P<0.0001)。
  • AUC分别为SUVmean 0.56、TLU 0.76、%ID 0.78。
  • %ID准确性最佳,截断值0.83时灵敏度65.0%、特异度83.8%。

关键数值与推荐

  • %ID截断值0.83,灵敏度65.0%,特异度83.8%,AUC 0.78。
  • TLU的AUC为0.76,SUVmean的AUC为0.56。

临床怎么用

  • 可利用定量肺灌注SPECT/CT的容积指标(尤其%ID)辅助区分CLAD与非CLAD肺,补充肺功能检查对区域肺变化检测的不足。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Chronic lung allograft dysfunction (CLAD) is a major cause of late morbidity after lung transplantation, and spirometry lacks the ability to detect regional lung changes. Thus, in this study, we investigated whether quantitative perfusion single-photon emission CT/CT parameters can distinguish CLAD from non-CLAD lungs and how they relate to pulmonary function. PATIENTS AND METHODS: This retrospective study included 80 lung transplant recipients who underwent SPECT/CT. Standardized uptake value (SUV) mean , total lung uptake (TLU), and percentage injected dose (%ID) were calculated, and group differences, receiver operating characteristic performance, and correlations with forced expiratory volume in 1 second, forced vital capacity, and total lung capacity were analyzed. RESULTS: No significant difference was observed for SUV mean ( P = 0.250), whereas TLU and %ID were significantly lower in CLAD ( P < 0.0001). Area under the curve values were 0.56 (SUV mean ), 0.76 (TLU), and 0.78 (%ID). %ID showed the best accuracy (cutoff: 0.83; sensitivity: 65.0%; specificity: 83.8%). CONCLUSIONS: Volume-based metrics, especially %ID, serve as useful noninvasive indicators for the assessment of CLAD.