文献速递肿瘤 PET/CT核素与放射性配体治疗放射性药物与辐射防护

质子治疗后全身动态PET/CT成像:质子诱导活度与生物学洗脱

Total-Body Dynamic PET/CT Imaging of Proton-Induced Activity and Biologic Washout After Proton Therapy.
PubMed 文献 · J Nucl Med · 2026-09-02

体模实验显示PET与模拟分布空间一致性好;患者中脑和乳腺的DSC/NCC均值约0.81。动态图像可观察到同位素活度在肿瘤内外经血循环的全身再分布与生物学洗脱。

要点

  • 近机房全身PET/CT可在质子治疗后超低活度下获得可解读图像。
  • 脑和乳腺靶区PET与蒙特卡罗模拟的空间一致性较高(DSC/NCC约0.81)。
  • 动态全身成像可捕捉质子诱导活度经血循环的全身洗脱与再分布。

核心结论

  • 近机房全身PET/CT能够在质子治疗后超低活度条件下实现可解读的成像。
  • 动态全身成像可捕获质子诱导活度经血循环的全身生物学洗脱,为后续洗脱建模和体内疗效评估方法学开发提供基础。

研究设计与样本

  • 系列体模实验以蒙特卡罗模拟活度分布为参考,评估全身PET在超低活度下的性能。
  • 采用Dice相似系数(DSC)和归一化互相关(NCC)量化PET与蒙特卡罗结果的空间相关性,并从感兴趣体积提取时间-活度曲线分析动态行为。

主要发现

  • 体模实验中,PET图像在超低活度下与蒙特卡罗参考分布显示密切的空间对应。
  • 患者中,相对静止靶区的PET与蒙特卡罗一致性更高,脑的DSC/NCC均值为0.81±0.09/0.81±0.09,乳腺为0.81±0.05/0.83±0.08。
  • 动态全身PET图像显示同位素活度在大体肿瘤体积内外的生物学洗脱和全身再分布,在心脏血池、主要血管及脾、肝等富血器官中富集。

临床怎么用

  • 质子治疗后可利用近机房全身PET/CT在超低活度下进行离线动态成像,评估质子诱导活度的空间分布。
  • 动态全身成像可观察活度经血循环的洗脱与再分布,为未来体内治疗评估提供方法学基础。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Off-line PET imaging after proton therapy is limited by transport delay and by the sensitivity and short axial field of view of conventional scanners, which hinder imaging at ultralow activity and characterization of whole-body biologic washout. We evaluated whether a near-room total-body PET/CT system could enable clinically practical imaging of proton-induced activity after treatment and its whole-body biologic washout. Methods: We conducted a series of phantom studies to evaluate the performance of total-body PET at ultralow activity with Monte Carlo (MC)-simulated activity distributions as references. Nineteen patients with solid tumors underwent off-line total-body dynamic PET/CT imaging shortly after proton therapy. Spatial correlation between PET and MC results was quantified using the Dice similarity coefficient (DSC) and normalized cross-correlation (NCC). Dynamic images were reconstructed, and time-activity curves were extracted from volumes of interest to analyze the dynamic behavior of proton-induced activity. Results: In phantom experiments, PET images showed close spatial correspondence to MC reference distributions under ultralow activity. In patients, the agreement between PET and MC was higher for relatively stationary targets, with a mean DSC/NCC of 0.81 ± 0.09/0.81 ± 0.09 for the brain and 0.81 ± 0.05/0.83 ± 0.08 for the breast. Dynamic total-body PET images revealed biologic washout and whole-body redistribution of isotope activity within and beyond the gross tumor volumes, showing enrichment within the cardiac blood pool, major blood vessels, and blood-rich organs, such as the spleen and liver. Conclusion: Near-room total-body PET/CT enabled interpretable imaging under ultralow activity after treatment. Dynamic total-body imaging additionally captured whole-body biologic washout of proton-induced activity through blood circulation, providing a foundation for future washout modeling and methodologic development for in vivo treatment assessment.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Tang H, Song S, Liu F, et al. Total-Body Dynamic PET/CT Imaging of Proton-Induced Activity and Biologic Washout After Proton Therapy. J Nucl Med. 2026. PMID: 42276783. doi:10.2967/jnumed.126.272338

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。