文献速递心脏核医学

深度学习衰减校正对负荷心肌灌注显像准确性的影响

Effect of deep learning attenuation correction on accuracy of stress myocardial perfusion imaging.
PubMed 文献 · J Nucl Cardiol · 2026-04-16

连续100例疑似冠心病患者接受DSPECT相机心肌灌注显像及冠状动脉造影,以左主干狭窄≥50%或其他狭窄≥70%定义CAD。自动分析SSS在全部系列中优于视觉分析,非衰减校正(NAC)的SSS检测CAD高度准确(AUC 0.915),深度学习衰减校正(DLAC)准确性低于NAC(SSS P=0.01,SDS P=0.0003)。

要点

  • 自动分析SSS在全部系列中优于视觉分析,SSS的NAC检测CAD的AUC为0.915。
  • DLAC准确性低于NAC(SSS P=0.01,SDS P=0.0003)。
  • SDS检测缺血时直立位优于组合图像(P=0.002)。

核心结论

  • 在DSPECT相机检测CAD时,自动分析SSS比视觉分析更准确,DLAC虽有效但非衰减校正方法更准确。

研究设计与样本

  • 连续100例疑似CAD患者接受DSPECT心肌灌注显像和冠状动脉造影,CAD定义为左主干狭窄≥50%或其他狭窄≥70%。

主要发现

  • 自动分析SSS在最初41例中与详细视觉分析无显著差异,在全部系列中优于视觉分析。
  • NAC的SSS检测CAD高度准确(AUC 0.915),SDS结果相似。
  • DLAC准确性低于NAC(SSS P=0.01,SDS P=0.0003)。
  • SDS分析中直立位成像优于组合图像(P=0.002)。
  • 逐像素可逆性分析中NAC正确分类93%患者,DLAC正确分类74%患者。

关键数值与推荐

  • CAD定义:左主干狭窄≥50%或其他狭窄≥70%。
  • NAC的SSS检测CAD的AUC为0.915。
  • DLAC与NAC比较:SSS P=0.01,SDS P=0.0003。
  • SDS直立位与组合图像比较P=0.002。
  • 逐像素分析正确分类率:NAC 93%,DLAC 74%。

临床怎么用

  • 在DSPECT相机心肌灌注显像中,可优先采用自动分析SSS而非视觉分析。
  • 尽管DLAC有效,非衰减校正方法在检测CAD方面更准确。
  • 检测缺血时直立位成像可能优于组合图像,提示可优化CZT成像协议。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Attenuation correction (AC) improves the accuracy of myocardial perfusion imaging for detecting coronary artery disease (CAD). There has been limited application of deep learning attenuation correction (DLAC) in cadmium zinc telluride (CZT) cameras. METHODS: We employed DLAC for CZT imaging in a consecutive series of 100 patients with suspected CAD who had myocardial perfusion imaging with a DSPECT camera and coronary angiography. CAD was defined as left main stenosis ≥50% or another stenosis ≥70%. Automated analysis was compared with visual interpretation for the summed stress score (SSS) and was employed before (non-attenuation correction, NAC) and after DLAC. Accuracy was compared across upright, supine, and combined imaging positions using receiver operating characteristic analysis of the SSS, summed difference score (SDS), and a pixel-by-pixel approach. RESULTS: Automated analysis of SSS was not dissimilar to detailed visual analysis in the first 41 patients and was superior to visual analysis for the entire series. The SSS with NAC was highly accurate in detecting CAD (area under curve (AUC): 0.915) and was similar for SDS. DLAC was less accurate than NAC (P = 0.01 for SSS and 0.0003 for SDS). For SDS, upright imaging was superior to combined images (P = 0.002). The pixel-by-pixel analysis for reversibility correctly classified 93% of patients with NAC and 74% of patients with DLAC. CONCLUSIONS: For detecting CAD with a DSPECT camera, automated analysis for SSS had greater accuracy than visual analysis. While DLAC was effective, non-AC methods proved to be more accurate. Upright imaging was superior to combined imaging for detecting ischemia by SDS, highlighting opportunities to optimize CZT imaging protocols.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Lima BB, Dupont WD, Carr CM, et al. Effect of deep learning attenuation correction on accuracy of stress myocardial perfusion imaging. J Nucl Cardiol. 2026. PMID: 42000122. doi:10.1016/j.nuclcard.2026.102706

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。