文献速递肿瘤 PET/CT

临床高效[18F]FDG PET/CT协议评估:短时动态与两时相静态成像鉴别肺部良恶性病变

Evaluation of a clinically efficient [18F]FDG PET/CT protocol: short dynamic and two-phase static imaging for differentiating malignant pulmonary lesions.
PubMed 文献 · EJNMMI Res · 2026-04-02

恶性病变的Patlak模型净流入率Ki显著高于非恶性病变(P=0.023),早期静态SUR(P=0.045)和2.5小时延迟SUR(P=0.029) also 显著更高且具有诊断准确性,而SUVmax及延迟SUVmax组间无显著差异。

要点

  • 10分钟动态联合两时相静态[18F]FDG PET/CT协议在优化调度的中心可行。
  • Patlak模型Ki、早期SUR和延迟SUR对鉴别肺部良恶性病变有显著诊断价值。
  • 传统SUVmax及延迟SUVmax未能显著区分恶性与非恶性肺部病变。

核心结论

  • 联合10分钟动态与两时相静态的[18F]FDG PET/CT协议可行,其衍生的Ki、SUR和延迟SUR对鉴别肺部良恶性病变有显著诊断价值,优于传统SUVmax。

主要发现

  • 恶性病变的Patlak模型净流入率Ki显著高于非恶性病变(P=0.023),ROC曲线AUC为0.729。
  • 标准静态扫描的SUR在恶性病变中显著更高(P=0.045,AUC=0.702)。
  • 2.5小时静态扫描的延迟SUR在恶性病变中显著更高(P=0.029,AUC=0.720)。
  • 标准SUVmax和延迟SUVmax在两组间无显著差异。

关键数值与推荐

  • Patlak模型Ki鉴别良恶性病变的ROC曲线AUC为0.729。
  • 标准静态扫描SUR的P值为0.045,AUC为0.702。
  • 2.5小时静态扫描延迟SUR的P值为0.029,AUC为0.720。

临床怎么用

  • 在具备优化调度条件的中心,可采用10分钟动态联合两时相静态[18F]FDG PET/CT协议。
  • 可应用Patlak图形分析获得Ki,并结合易计算的SUR及延迟SUR辅助鉴别肺部病变良恶性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Pulmonary lesions affect a large population globally, posing huge challenges in clinical management and public healthcare. Functional imaging-based diagnosis facilitates the classification and treatment planning for pulmonary lesions. [18F]FDG PET/CT is a valuable tool for evaluating pulmonary lesions, but it is limited by false-positive uptake in inflammatory processes. Although quantitative kinetic analysis can improve diagnostic specificity, long dynamic acquisitions pose practical challenges in clinical settings and compromise patient comfort. This study evaluated an efficient and clinically practical protocol combining a 10-min dynamic scan with two-phase static scanning to improve diagnostic accuracy. RESULTS: Forty patients with pulmonary lesions confirmed by histopathology (28 malignant, 12 non-malignant) were included in the analysis. Kinetic parameters were derived from time-activity curves generated by integrating dynamic and static data points using different compartment models with image-derived input functions. Semi-quantitative parameters, including maximum standardized uptake value (SUVmax), tumor-to-blood standard uptake ratio (SUR) from the early static scan, and delayed SUVmax and delayed SUR from the delayed static scan, were also calculated and assessed. Malignant lesions showed significantly higher net influx rates (Ki) calculated from Patlak model compared with non-malignant lesions (P = 0.023). The receiver operating characteristic (ROC) curve analysis for Ki yielded an area under the curve (AUC) of 0.729. Both SUR from the standard static scan (P = 0.045, AUC = 0.702) and delayed SUR from the 2.5-h static scan (P = 0.029, AUC = 0.720) were significantly higher in malignant lesions and demonstrated significant diagnostic accuracy. Standard SUVmax, and delayed SUVmax did not show significant differences between groups. CONCLUSIONS: The combined 10-min dynamic and two-phase static [18F]FDG PET/CT protocol may be feasible in selected centers with optimized scheduling. When applicable, this method allows derivation of the net influx rate Ki from Patlak graphical analysis as well as the easily calculated semi-quantitative parameters SUR and delayed SUR, all of which demonstrate significant diagnostic value for differentiating malignant from non-malignant pulmonary lesions, outperforming conventional SUVmax.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Jia Y, Qiu R, Han C, et al. Evaluation of a clinically efficient [18F]FDG PET/CT protocol: short dynamic and two-phase static imaging for differentiating malignant pulmonary lesions. EJNMMI Res. 2026. PMID: 41928032. doi:10.1186/s13550-026-01419-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。