锝-99m Technegas SPECT/CT 定位持续性肺漏气
该病例系列纳入20例胸外科术后怀疑持续性肺漏气(PAL)的患者,采用锝-99m Technegas 通气SPECT/CT(vSPECT)进行术前定位,并与术中水试验(iWST)及临床转归对照。结果显示vSPECT在多数病例中可成功定位PAL,提示其是评估临床怀疑PAL患者的有用且准确的方法。
要点
- 锝-99m Technegas 通气SPECT/CT可用于胸外科术后持续性肺漏气的无创定位。
- 20例中10例vSPECT定位的PAL经术中水试验确认,4例虽未确认但按vSPECT指示手术控制了漏气。
- 2例vSPECT未显示PAL,其中1例为穿刺孔疝所致。
核心结论
- Technegas 通气SPECT/CT对临床怀疑持续性肺漏气的患者是有用且准确的评估方法。
研究设计与样本
- 病例系列研究,纳入20例胸外科术后怀疑持续性肺漏气的患者。
- Technegas按制造商说明使用Cyclomedica TechnegasPlus发生器制备和给药。
- SPECT投影在配备低能高分辨率(LEHR)准直器的Siemens Symbia Intevo Bold伽马相机上采集。
- 回顾患者记录,将影像与术中评估及后续临床过程进行关联。
主要发现
- 手术时中位年龄为68.5岁。
- 手术指征包括肺部肿瘤16例(肺叶/肺段切除)、慢性阻塞性肺疾病2例(肺减容术)、胸膜孤立性纤维瘤1例(叶间胸膜剥脱术)、胸腺瘤1例(胸腺切除/心包切除术)。
- 10/20例vSPECT成功定位PAL,随后经iWST确认。
- 4/20例vSPECT定位PAL但未经iWST确认,按vSPECT指示部位手术干预控制了漏气。
- 4/20例vSPECT识别的PAL因胸腔引流量减少而保守处理。
临床怎么用
- 对胸外科术后临床怀疑持续性肺漏气的患者,可考虑行锝-99m Technegas 通气SPECT/CT术前定位。
- vSPECT定位结果可指导手术干预部位的选择。
局限性
- 原文未报告研究的局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Effective surgical management of persistent air leaks (PAL) after thoracic surgery depends on their quick and reliable localization, which has been hitherto limited to the intraoperative water submersion test (iWST). We present a case series of 20 patients examined for PAL using technetium-99m Technegas ventilation SPECT/CT (vSPECT). PATIENTS AND METHODS: Technegas was prepared and administered according to the manufacturer's instructions using a Cyclomedica TechnegasPlus generator. SPECT projections were acquired on a Siemens Symbia Intevo Bold gamma camera equipped with a low-energy high-resolution (LEHR) collimator. We reviewed patient records, correlating imaging with intraoperative assessment and the subsequent clinical course. RESULTS: The median age at the time of surgery was 68.5 years. Surgical indications were pulmonary neoplasm (n = 16, lobectomy/segmentectomy), chronic obstructive pulmonary disease (n = 2, lung volume reduction surgery), solitary fibrous tumor of the pleura (n = 1, fissural pleurectomy), and thymoma (n = 1, thymectomy/pericardectomy). In 10/20 cases, vSPECT successfully located PAL subsequently confirmed by iWST. In 4/20 cases, vSPECT located PAL without confirmation by iWST, however, surgical intervention at the site indicated on vSPECT curbed the leak. In 4/20 cases, PALs identified on vSPECT were managed conservatively as thoracic drainage volumes decreased. In 2/20 cases, vSPECT did not display a PAL; in 1 case, a trocar hernia was found responsible, in another case, revision surgery was deferred, and fistulation resolved without intervention. CONCLUSIONS: Technegas ventilation SPECT/CT appears to be a useful and remarkably accurate modality for the assessment of patients with clinical suspicion of PAL.
引用
- Krieger K, Heil A, Gelpke H, et al. Localization of Persistent Air Leaks Using Technetium-99m Technegas SPECT/CT. Clin Nucl Med. 2025. PMID: 41481851. doi:10.1097/RLU.0000000000006247
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。