SPECT增加比率可作为无PET设施中已知或疑似冠心病患者的预后指标
本研究回顾性分析60例已知或疑似冠心病患者,比较负荷-静息99mTc-sestamibi SPECT衍生的增加比率(IR)与13N-氨PET衍生的心肌血流储备(MFR)。结果显示SPECT-IR与PET-MFR相关,可预测显著CAD,并以IR阈值1.13(对应MFR 2.0)预测不良事件。
要点
- 整体IR随CAD严重程度增加而降低,非狭窄血管中MFR<2.0者区域IR更低。
- IR阈值1.13对应MFR 2.0,9例事件中8例IR<1.13。
核心结论
- SPECT-IR与PET-MFR及CAD严重程度相关,可能预测已知或疑似CHD患者的不良结局。
研究设计与样本
- 回顾性分析60例已知或疑似冠心病患者,均行负荷-静息99mTc-sestamibi SPECT和13N-氨PET。
主要发现
- 整体IR和整体MFR均随CAD严重程度增加而降低。
- 非狭窄血管中,MFR<2.0患者的区域IR显著低于MFR≥2.0者。
- 中位随访765天,9例发生主要事件,其中8例IR<1.13。
- ROC曲线分析显示IR对不良事件有良好预测能力。
关键数值与推荐
- IR阈值1.13对应MFR 2.0。
临床怎么用
- 在无PET设施中,SPECT-IR可作为PET-MFR的潜在替代指标,用于评估已知或疑似CHD患者的预后。
局限性
- 回顾性研究,样本量60例,事件数少(9例)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The clinical significance of single-photon emission computed tomography (SPECT)-derived increase ratio (IR) remains unclear. This study aimed to investigate whether SPECT- IR can diagnose significant coronary artery disease (CAD), correlate with positron emission tomography (PET)-derived myocardial flow reserve (MFR), and predict the composite endpoint. METHODS: We retrospectively analyzed 60 patients with known or suspected coronary heart disease (CHD) who underwent stress-rest 99mTc-sestamibi myocardial perfusion SPECT and 13N-ammonia PET. Global and regional SPECT-IR and PET-MFR were measured. The endpoint of this study was a composite of all-cause mortality and major adverse cardiovascular events. RESULTS: Global and regional IR predicted significant CAD, and IR correlated with their respective MFRs (global: r = .43, r2 = .18, P < .001; regional: r = .34, r2 = .12, P < .001). The global IR decreased with advancing CAD severity, as did global MFR. Among nonstenotic vessels, regional IR was significantly lower in patients with MFR <2.0 than in those with MFR ≥2.0. The SPECT-IR may also predict the need for early revascularization as well as PET-MFR. During a median follow-up of 765 days, nine primary events occurred. Using an IR threshold of 1.13, corresponding to an MFR of 2.0, eight of nine patients with events had IR < 1.13. The receiver operating characteristic (ROC) curve analysis of IR showed good predictive ability for adverse events. CONCLUSION: SPECT-IR is associated with PET-MFR and CAD severity. The SPECT-IR may be a potential predictor of adverse outcomes in patients with known or suspected CHD.
引用
- Katoh S, Watanabe T, Mito T, et al. Single-photon emission computed tomography-increase ratio, a potential alternative to positron emission tomography-myocardial flow reserve, is a useful prognostic indicator in patients with known or suspected coronary heart disease at facilities without positron emission tomography. J Nucl Cardiol. 2025. PMID: 41591947. doi:10.1016/j.nuclcard.2025.102536
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。