68Ga-FAPI PET/CT用于溃疡性结肠炎与克罗恩病的无创表征及活动度评估
本研究纳入43例IBD患者和43例对照,用68Ga-FAPI-46 PET/CT评估疾病活动度并以结肠镜为参照。活动期患者均至少有一个强烈FAPI阳性病灶,活动期病灶及患者层面摄取显著高于非活动期;CD与UC病灶摄取同样高。
要点
- 活动期IBD患者均至少有一个强烈FAPI阳性病灶,非活动期仅4/14有FAPI阳性病灶。
- CD与UC的病灶FAPI摄取同样高,活动期摄取显著高于非活动期。
- FAPI阳性IBD病灶呈两种动力学模式:持续上升型或早期峰值后平台型。
核心结论
- 68Ga-FAPI-46 PET/CT在评估CD和UC的成纤维细胞激活相关疾病活动度方面有应用前景。
研究设计与样本
- 本分析纳入43例IBD患者和43例对照患者,均行68Ga-FAPI-46 PET/CT检查。
- IBD患者疾病活动度由结肠镜评估,FAPI阳性胃肠道 findings 与健康表现GI结构被勾画分析。
主要发现
- 共检查20例CD和23例UC患者,其中29例活动期、14例非活动期。
- IBD患者多数健康表现GI结构的FAPI摄取较对照显著增高。
- 80个FAPI阳性GIT findings中14个被排除为非IBD相关,最终分析66个FAPI阳性IBD病灶。
- CD与UC的病灶FAPI摄取同样高;活动期患者均至少有一个强烈FAPI阳性IBD病灶,非活动期仅4/14有FAPI阳性病灶。
- 活动期病灶及患者层面FAPI摄取显著高于非活动期;FAPI阳性IBD病灶呈两种动力学模式:持续上升型或早期峰值后平台型。
临床怎么用
- 68Ga-FAPI-46 PET/CT或可用于无创评估CD和UC的成纤维细胞激活相关疾病活动度。
- 判读时需注意IBD患者健康表现GI结构也可出现FAPI摄取增高,并需排除非IBD相关FAPI阳性GIT findings。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Inflammatory Bowel Diseases (IBD) comprise ulcerative colitis (UC) and Crohn's disease (CD). Management of IBD requires assessment of disease activity, severity, extent and complications. Here, we describe the signal behavior of both CD and UC in 68Gallium- fibroblast activation protein inhibitor-based radiopharmaceuticals-46-positron emission tomography (68Ga-FAPI-46-PET) and evaluate the potential of 68Ga-FAPI-46-PET for activity assessment in IBD. PATIENTS AND METHODS: This analysis includes data of 43 IBD patients and 43 control patients examined by 68Ga-FAPI-46-PET/computed tomography (CT). Disease activity of IBD patients was assessed by colonoscopy. FAPI-positive gastrointestinal tract (GIT)-findings and healthy appearing GI structures were contoured. Non-IBD related FAPI-positive GIT-findings were ruled out by interdisciplinary consensus. Static and dynamic PET-parameters of FAPI-positive IBD lesions and healthy appearing GI structures were extracted and PET signalling was analyzed with respect to IBD subtype and disease activity. RESULTS: We examined 20 CD patients and 23 UC patients (29 with active, 14 with inactive disease). FAPI-uptake in most healthy appearing GI structures of IBD patients was significantly increased compared to controls. Of 80 FAPI-positive GIT-findings, 14 were ruled out as non-IBD related and 66 FAPI-positive IBD lesions were analyzed. We observed equally high lesional FAPI-uptake in CD and UC. All patients with active disease showed at least one intensively FAPI-positive IBD lesion, while only 4/14 patients with inactive disease showed any FAPI-positive IBD lesion. Lesional and patientwise FAPI-uptake was significantly higher in active than in inactive disease. FAPI-positive IBD lesions showed a characteristic kinetic behaviour with two types of uptake patterns - one showing a continuous increase and the other an early peak followed by a plateau. CONCLUSION: 68Ga-FAPI-46-PET/CT appears promising for assessing disease activity in terms of fibroblast activation in both CD and UC.
引用
- Debus J, von Götze I, Brandt J, et al. 68Ga-FAPI PET/CT for non-invasive characterization and activity assessment of ulcerative colitis and Crohn´s disease. Eur J Nucl Med Mol Imaging. 2026. PMID: 41483304. doi:10.1007/s00259-025-07686-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。