文献速递肿瘤 PET/CT

[18F]FAPI-42与[18F]FDG摄取模式差异可鉴别硬纤维瘤与GIST

Differential [18F]FAPI-42 and [18F]FDG uptake patterns distinguish desmoid tumours from GISTs on PET/CT imaging.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2026-01-03

本研究回顾性纳入24例患者(12例腹腔内硬纤维瘤IADT、12例复发/转移性GIST),分别行[18F]FAPI-42与[18F]FDG PET/CT。IADT的FAPI SUVmax显著高于GIST,FDG SUVmax显著低于GIST,FAPI/FDG比值显著更高;三者AUC分别为0.743、0.819、0.896,免疫组化证实IADT的FAP表达更高。

要点

  • IADT的[18F]FAPI-42 SUVmax显著高于GIST,而[18F]FDG SUVmax显著低于GIST。
  • FAPI/FDG SUVmax比值鉴别两者AUC达0.896,准确率87.5%。
  • 免疫组化示IADT的FAP表达显著高于GIST,与FAPI摄取一致。

核心结论

  • IADT与GIST在[18F]FAPI-42和[18F]FDG PET/CT上呈现不同摄取特征,两种示踪剂可能提供互补诊断信息。

研究设计与样本

  • 回顾性纳入24例患者,其中IADT 12例、复发/转移性GIST 12例,均分别行[18F]FAPI-42与[18F]FDG PET/CT。
  • 比较两组SUVmax-FAPI、SUVmax-FDG及FAPI/FDG SUVmax比值,并行ROC曲线分析。
  • 采用免疫组化验证所有IADT与GIST病灶的FAP表达。

主要发现

  • IADT的SUVmax-FAPI为8.8(7.2, 10.6),显著高于GIST的3.9(2.8, 7.6),P=0.045。
  • IADT的SUVmax-FDG为2.5(1.9, 3.5),显著低于GIST的6.1(3.6, 8.3),P=0.007。
  • IADT的FAPI/FDG SUVmax比值为3.3(2.2, 4.1),显著高于GIST的0.8(0.3, 1.4),P<0.001。

关键数值与推荐

  • SUVmax-FAPI、SUVmax-FDG及FAPI/FDG比值的AUC分别为0.743、0.819、0.896,准确率分别为75.0%、83.3%、87.5%。
  • 免疫组化示IADT的FAP表达显著高于GIST(P=0.002);IADT多为强阳性3+(8/12,66.7%),GIST多为弱阳性1+或无染色(7/12,58.3%)。

临床怎么用

  • 对拟诊复发/转移性GIST而FDG摄取不典型者,可加做[18F]FAPI-42 PET/CT,结合FAPI/FDG比值辅助鉴别IADT。

局限性

  • 本研究为回顾性设计,样本量较小(共24例),结论需更大样本验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Intra-abdominal desmoid tumours (IADT) can closely mimic gastrointestinal stromal tumours (GISTs), particularly in recurrence and metastases. However, differentiating these two diseases using radiological methods remains challenging. This study aimed to investigate the value of [18F]FAPI-42 PET/CT in differentiating IADT and GISTs compared to [18F]FDG PET/CT. METHODS: This study retrospectively included a total of 24 patients (12 patients with IADT and 12 patients with recurrent/metastatic GISTs) who underwent two separate PET/CT scans using [18F]FAPI-42 and [18F]FDG, respectively. The differences in tumour SUVmax on [18F]FAPI-42 PET/CT (SUVmax-FAPI) and [18F]FDG PET/CT (SUVmax-FDG) and the ratio of tumour SUVmax on FAPI PET/CT to SUVmax on FDG PET/CT [SUVmax ratio (FAPI/FDG)] were compared between IADT and GISTs. Receiver operating characteristic (ROC) curve analyses were performed to evaluate the diagnostic performance of these parameters in differentiating IADTs from GISTs. Immunohistochemistry was used to verify FAP expression in all IADT lesions and GISTs lesions. RESULTS: The SUVmax of IADTs on [18F]FAPI-42 PET/CT was significantly higher than that of GISTs [8.8 (7.2, 10.6) vs. 3.9 (2.8, 7.6), P = 0.045], whereas the SUVmax of IADTs on [18F]FDG PET/CT was significantly lower than that of GISTs [2.5 (1.9, 3.5) vs. 6.1 (3.6, 8.3), P = 0.007]. The SUVmax ratio (FAPI/FDG) of IADTs was significantly higher than that of GISTs [3.3 (2.2, 4.1) vs. 0.8 (0.3, 1.4), P < 0.001]. SUVmax-FAPI, SUVmax-FDG, and the SUVmax ratio (FAPI/FDG) achieved AUCs of 0.743, 0.819, and 0.896, with corresponding accuracies of 75.0%, 83.3%, and 87.5%, respectively, for distinguishing IADT from GISTs. Immunohistochemistry revealed significantly higher FAP expression in IADTs compared to GISTs (P = 0.002), with most IADTs showing strong (3+) staining (8/12, 66.7%), while GISTs primarily demonstrated weak (1+) or no staining (7/12, 58.3%). CONCLUSION: The distinct uptake characteristics of [18F]FAPI-42 and [18F]FDG observed in IADTs and GISTs provide preliminary evidence that these two tracers may offer complementary diagnostic information when evaluating desmoid tumours that mimic recurrent or metastatic GISTs.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Wu C, Wang X, Lin X, et al. Differential [18F]FAPI-42 and [18F]FDG uptake patterns distinguish desmoid tumours from GISTs on PET/CT imaging. Eur J Nucl Med Mol Imaging. 2026. PMID: 41483308. doi:10.1007/s00259-025-07707-z

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。