老年患者心肌灌注显像诊断准确性:AMICO登记研究亚分析

Accuracy of myocardial perfusion imaging in older patients: Insights from a sub-analysis of the AMICO registry.
PubMed 文献 · J Nucl Cardiol · 2025-10-10

基于AMICO登记研究,纳入627例年龄>70岁老年患者及627例匹配对照,评估镉锌碲相机心肌灌注显像(MPI)检测冠心病(CAD)及预测预后的准确性。老年患者运动负荷MPI诊断准确性低于对照,特异性更低,与运动负荷能力和心率血压乘积储备降低相关;较高 summed difference score(SDS)为MACE独立预测因子。

核心结论

  • 老年患者运动负荷MPI诊断准确性低于对照,归因于运动能力受损。
  • 较高SDS是老年患者MACE的独立预测因子。

研究设计与样本

  • AMICO登记研究亚分析,纳入627例年龄>70岁老年患者及627例匹配对照。
  • 患者接受运动或血管扩张剂负荷MPI及冠状动脉造影,随访平均4.1±2.4年。

主要发现

  • 老年患者梗阻性CAD为426/627(68%),对照为410/627(65%)。

关键数值与推荐

  • 缺血定义为summed difference score(SDS)>3。
  • 冠状动脉狭窄>70% considered obstructive。

临床怎么用

  • 老年患者运动负荷MPI诊断准确性较低,解读时应考虑运动能力受损的影响。
  • 较高SDS可用于老年患者MACE风险分层。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: To assess the accuracy of myocardial perfusion imaging (MPI) on a cadmium-zinc-telluride camera in detecting coronary artery disease (CAD) and predicting prognosis in older patients. METHODS: Six hundred and twenty-seven older patients (aged >70 years) and the same number of matched controls were submitted to exercise or vasodilator-stress MPI and coronary angiography. The rate-pressure product (RPP) reserve (stress/rest) was computed as a measure of cardiac workload during exercise. Ischemia was defined as a summed difference score (SDS) >3. Coronary stenoses >70% were considered obstructive. Patients were followed (mean 4.1 ± 2.4 years) for a composite of cardiovascular death, nonfatal myocardial infarction, and urgent revascularization (MACE). RESULTS: Obstructive CAD was revealed in 426/627 patients (68%) and 410/627 controls (65%). While in the overall population MPI showed a significant accuracy for detecting obstructive CAD (AUC: .79, 95% confidence interval [CI]: .77-.82; P < .001), test accuracy seemed to decrease with older age, with older patients showing lower specificity than controls (72% vs 64%, respectively; P = .002). This difference was exclusively limited to patients undergoing exercise-stress, whereby the overall test accuracy was significantly lower in older patients than controls (AUC: .82 vs .75; P = .03). Older patients attained a significantly lower peak workload (101 ± 26 W vs 111 ± 34 W; P < .001) and RPP reserve during exercise than controls (1.9 ± .9 vs 2.2 ± .7, P < .001), resulting in an independent predictor of reduced diagnostic specificity (odds ratio: .68, 95% CI: .50-.96; P = .027). At multivariable Cox regression analysis, a higher SDS was an independent predictor of major adverse cardiac events (MACE) (HR 1.11, 95% CI: 1.07-1.14; P < .001). CONCLUSIONS: In older patients, exercise-stress MPI shows a lower diagnostic accuracy than in controls because of an impaired exercise capacity.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Liga R, Filidei E, Runza G, et al. Accuracy of myocardial perfusion imaging in older patients: Insights from a sub-analysis of the AMICO registry. J Nucl Cardiol. 2025. PMID: 41075927. doi:10.1016/j.nuclcard.2025.102530