动态[18F]FDG PET显像用于区分骨折相关感染中感染与炎症的临床评估
前瞻性研究纳入31例患者共33处疑似骨折相关感染(FRI)骨折,采用长轴视野PET/CT行动态[18F]FDG显像65分钟,以FRI共识组标准为参考,基于时间-活性曲线(TAC)的诊断准确率为94%,感染组骨折SUVpeak随时间进行性升高而炎症组趋于平台(p < 0.001)。
要点
- 动态[18F]FDG PET/CT基于TAC诊断FRI的灵敏度86%、特异度100%、PPV 100%、NPV 90%、准确率94%。
- 感染组骨折SUVpeak随时间进行性升高,炎症组摄取趋于平台(p < 0.001)。
- 标准影像定量与视觉评估的准确率分别为91%和88%,动态影像视觉判读为82%。
核心结论
- 这项概念验证研究表明,使用TAC的动态[18F]FDG PET/CT可在疑似FRI患者中区分感染与炎症,观察到高诊断准确率,并提示较标准影像可能具有优势。
- 作者提出需要更大规模的研究来验证这些结果并探索动态显像在感染管理中的完整临床潜力。
研究设计与样本
- 前瞻性研究,纳入2021年12月至2024年11月转诊行[18F]FDG PET/CT以检测FRI(范围)的患者。
- 共纳入31例患者、33处疑似感染骨折,最终临床FRI诊断依据FRI共识组标准确立并作为参考标准。
- 使用长轴视野PET/CT系统,于[18F]FDG注射后65分钟内行动态PET显像,分析TAC比较确诊感染与炎症的摄取模式,并计算诊断准确率与常规标准影像比较。
主要发现
- 33处骨折中14处(42%)临床确诊感染。
- 基于TAC的动态影像诊断FRI的灵敏度86%、特异度100%、PPV 100%、NPV 90%,诊断准确率94%。
- 感染组骨折SUVpeak随时间进行性升高,而炎症组摄取似达到平台(p < 0.001)。
- 动态影像视觉判读的诊断准确率为82%;标准影像定量与视觉评估的诊断准确率分别为91%和88%。
关键数值与推荐
- FRI最终临床诊断依据FRI共识组定义的 criteria 确立,并作为参考标准。
- 动态[18F]FDG PET/CT于[18F]FDG注射后65分钟内采集。
- 基于TAC的动态影像诊断FRI:灵敏度86%、特异度100%、PPV 100%、NPV 90%、准确率94%。
- 动态影像视觉判读诊断准确率82%;标准影像定量评估准确率91%、视觉评估准确率88%。
- 感染组骨折SUVpeak随时间进行性升高 vs 炎症组摄取似达平台(p < 0.001)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文结论指出需要更大规模的研究来验证这些结果并探索动态显像在感染管理中的完整临床潜力。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Standard [18F]FDG PET/CT is widely used to detect infections, but is limited in differentiating bacterial infection from inflammation due to overlapping uptake patterns. This distinction is particularly challenging in fracture-related infection (FRI), due to multiple factors, including recent surgery, soft tissue injury, fracture healing, and surgical implants. Dynamic [18F]FDG imaging over time may overcome this limitation by capturing a rapid, sustained uptake seen in infections, driven by ongoing immune and microbial activity, as opposed to the potentially slower uptake in inflammation. This study investigates the potential of dynamic [18F]FDG PET/CT using time-activity curves (TACs) to distinguish infection from inflammation in patients with suspected FRI. METHODS: A prospective study was performed in patients referred for [18F]FDG PET/CT examination to detect (the extent of) FRI from December 2021 until November 2024. Final clinical diagnosis of FRI was established according to the criteria defined by the FRI consensus group and used as a reference standard. Dynamic PET imaging was performed using a long axial field-of-view PET/CT system over a 65-minute period after [18F]FDG injection. TACs were analyzed to compare uptake patterns between confirmed infections and inflammation, and diagnostic accuracy was calculated and compared to conventional standard imaging. RESULTS: Thirty-one patients with 33 fractures suspected of infection were included. Infection was clinically confirmed in 14 fractures (42%). Diagnosis of FRI based on dynamic imaging using TACs resulted in a high sensitivity of 86%, specificity of 100%, PPV of 100% and NPV of 90%, resulting in a diagnostic accuracy of 94%. In the infection group, Fracture SUVpeak increased progressively over time, while in the inflammation group, uptake appeared to reach a plateau (p < 0.001). Visual interpretation of the dynamic imaging yielded a diagnostic accuracy of 82%. For standard imaging, quantitative and visual assessments showed diagnostic accuracies of 91% and 88%, respectively. CONCLUSION: This proof-of-concept study demonstrates that dynamic [18F]FDG PET/CT using TACs can distinguish infection from inflammation in patients with suspected FRI, with high diagnostic accuracy observed, and suggesting a potential advantage over standard imaging. Larger-scale studies are needed to validate these results and explore the full clinical potential of dynamic imaging in infection management.
引用
- van Rijsewijk ND, Wouthuyzen-Bakker M, van Snick JH, et al. Clinical evaluation of dynamic [18F]FDG PET imaging to distinguish infection from inflammation in fracture-related infections. Eur J Nucl Med Mol Imaging. 2025. PMID: 40974409. doi:10.1007/s00259-025-07563-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。