文献速递肿瘤 PET/CT

连接子对[68Ga]Ga-NOTA-X-RM26靶向GRPR PET显像影响的临床前研究

A preclinical study on the influence of linkers in [68Ga]Ga-NOTA-X-RM26 radiotracers for PET imaging of GRPR expression.
PubMed 文献 · EJNMMI Res · 2025-08-07

本研究设计三种含不同结构限制性连接子的[68Ga]Ga-NOTA-X-RM26放射性配体,在PC-3前列腺癌小鼠模型中进行生物分布与PET显像评价。结果显示三种探针均具有高且GRPR特异性的肿瘤摄取,其中含N-乙酰赖氨酸-oET连接子的探针背景清除最快、显像最佳,但肝、胃肠道和胰腺摄取较高,需进一步优化以降低健康组织摄取。

要点

  • 三种[68Ga]Ga-NOTA-X-RM26探针均实现高放化产率、纯度和摩尔活度,对PC-3细胞呈GRPR特异性拮抗结合。
  • 注射后2小时生物分布显示三种探针均有高GRPR介导的肿瘤摄取,同时肝、胃肠道和胰腺摄取明显。
  • 含N-乙酰赖氨酸-oET连接子的探针背景清除最快、前列腺癌移植瘤PET显像更优,但需进一步优化降低健康组织摄取。

核心结论

  • 三种探针中,含N-乙酰赖氨酸-oET连接子的肽背景清除最快,对前列腺癌移植瘤的PET显像更优。
  • 引入构象限制性连接子是开发高GRPR结合与良好显像性能示踪剂的有前景策略,但需进一步优化以降低健康组织摄取。

研究设计与样本

  • 临床前研究,设计三种经不同连接子(N-乙酰赖氨酸后接oET、oMA或mMA基序)偶联NOTA螯合剂的RM26衍生放射性配体。
  • 三种肽均用Ga-68标记,在PC-3前列腺癌荷瘤小鼠中于注射后2小时进行生物分布研究,并评价PET显像。

主要发现

  • 三种肽标记后均获得高放化产率、纯度和摩尔活度。
  • 三种[68Ga]标记肽对PC-3细胞呈高且GRPR特异性结合,表现为拮抗行为,对GRPR的IC50值在个位数纳摩尔范围。
  • 注射后2小时生物分布显示三种探针均有高GRPR介导的肿瘤摄取,同时见高肝肠排泄、肝与胃肠道摄取升高及明显胰腺摄取。
  • 含N-乙酰赖氨酸-oET连接子的肽背景清除最快,前列腺癌移植瘤PET显像更优。

局限性

  • 原文结论指出需进一步优化以降低健康组织摄取。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Gastrin-releasing peptide receptor (GRPR) is overexpressed in several cancers, including prostate and breast, making it an attractive target for radiopharmaceutical development. Studies on GRPR-targeting radioligands highlight the critical role of the spacer region between the GRPR-recognition motif and radiolabeled moiety, which can significantly influence peptide pharmacokinetics and pharmacodynamics. Herein, we investigated the impact of structurally restricted spacers on the performance of RM26-based radioligands. RESULTS: Three novel radioligands were designed to each bear a NOTA chelator via different spacers composed of N-acetyl-lysine followed by either o-ethyltoluene (oET), o-methylanisole (oMA), or m-methylanisole (mMA) motifs. The peptides were successfully labeled with Ga-68, achieving high radiochemical yield, purity, and molar activity. The resulting [68Ga]-labeled peptides demonstrated high and GRPR-specific binding to prostate cancer PC-3 cells, antagonistic behavior, and the IC50 values to GRPR were in the single-digit nanomolar range. Biodistribution studies at 2 h post-injection in PC-3 xenograft-bearing mice revealed high, GRPR-mediated tumor uptake for all three radioligands. In addition, high hepatobiliary excretion with elevated uptake in the liver and the gastrointestinal tract and pronounced pancreatic uptake were observed. CONCLUSIONS: Among the three radioligands, the peptide bearing the N-acetyl-lysine-oET spacer exhibited the fastest background clearance and better PET imaging of prostate cancer xenografts. The incorporation of conformationally restricted spacers is a promising strategy for developing tracers with high GRPR binding and good imaging properties, but further optimization is necessary to reduce uptake in healthy tissues.

来源:EJNMMI Res,查看原文。版权归原作者所有。

引用

  1. Olaniran Håkansson E, Zelepukin IV, Obeid K, et al. A preclinical study on the influence of linkers in [68Ga]Ga-NOTA-X-RM26 radiotracers for PET imaging of GRPR expression. EJNMMI Res. 2025. PMID: 40775579. doi:10.1186/s13550-025-01301-y

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。