文献速递甲状腺核医学肿瘤 PET/CT

数字与模拟PET在甲状旁腺显像中的比较:PET指标与机器学习特征分析功能亢进病灶(DIGI-PET研究)

Digital versus analogue PET in parathyroid imaging: comparison of PET metrics and machine learning-based characterisation of hyperfunctioning lesions (the DIGI-PET study).
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-08-22

该研究比较数字与模拟PET/CT在甲状旁腺功能亢进中的定量指标,并评估机器学习能否区分甲状旁腺腺瘤与增生。结果显示数字PET检测到的病灶代谢体积和最大径均显著小于模拟PET,腺瘤SUVmax和TBR显著高于增生,LASSO模型区分腺瘤与增生的AUC为0.811。

要点

  • 数字PET较模拟PET检出更小的甲状旁腺病灶,代谢体积和最大径均显著更小。
  • 甲状旁腺腺瘤SUVmax和TBR显著高于增生,鉴别腺瘤的阈值为SUVmax>5.89和TBR>11.5。
  • LASSO模型区分腺瘤与增生的AUC为0.811,准确率79.7%,敏感性与特异性均衡。

核心结论

  • 数字PET在检测小甲状旁腺病灶方面优于模拟系统。
  • 对PET衍生指标和PTH的机器学习分析可能支持无创区分腺瘤与增生。

研究设计与样本

  • 初始多中心队列179例患者中纳入86例,共89个经组织学证实的PET阳性病灶(74个腺瘤,15个增生)。
  • 比较数字与模拟PET扫描仪的定量PET参数(SUVmax、MTV、TBR、最大径)及血清PTH和钙水平,采用Mann-Whitney U检验。
  • 采用ROC分析确定最佳阈值,并以LASSO、决策树、高斯朴素贝叶斯模型基于 harmonised 定量特征区分腺瘤与增生。

主要发现

  • 数字PET检测到的病灶代谢体积小于模拟PET(1.32 ± 1.39 vs. 2.36 ± 2.01 cc;p < 0.001)。
  • 数字PET检测到的病灶最大径小于模拟PET(8.35 ± 4.32 vs. 11.87 ± 5.29 mm;p < 0.001)。
  • 腺瘤SUVmax高于增生(8.58 ± 3.70 vs. 5.27 ± 2.34;p < 0.001)。
  • 腺瘤TBR高于增生(14.67 ± 6.99 vs. 8.82 ± 5.90;p < 0.001)。
  • 最佳机器学习模型(LASSO)区分腺瘤与增生的AUC为0.811,准确率79.7%,敏感性与特异性均衡。

关键数值与推荐

  • 鉴别甲状旁腺腺瘤的最佳阈值为SUVmax > 5.89和TBR > 11.5。
  • LASSO模型区分腺瘤与增生的AUC为0.811,准确率79.7%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: To compare PET-derived metrics between digital and analogue PET/CT in hyperparathyroidism, and to assess whether machine learning (ML) applied to quantitative PET parameters can distinguish parathyroid adenoma (PA) from hyperplasia (PH). METHODS: From an initial multi-centre cohort of 179 patients, 86 were included, comprising 89 PET-positive lesions confirmed histologically (74 PA, 15 PH). Quantitative PET parameters-maximum standardised uptake value (SUVmax), metabolic tumour volume (MTV), target-to-background ratio (TBR), and maximum diameter-along with serum PTH and calcium levels, were compared between digital and analogue PET scanners using the Mann-Whitney U test. Receiver operating characteristic (ROC) analysis identified optimal threshold values. ML models (LASSO, decision tree, Gaussian naïve Bayes) were trained on harmonised quantitative features to distinguish PA from PH. RESULTS: Digital PET detected significantly smaller lesions than analogue PET, in both metabolic volume (1.32 ± 1.39 vs. 2.36 ± 2.01 cc; p < 0.001) and maximum diameter (8.35 ± 4.32 vs. 11.87 ± 5.29 mm; p < 0.001). PA lesions showed significantly higher SUVmax and TBR compared to PH (SUVmax: 8.58 ± 3.70 vs. 5.27 ± 2.34; TBR: 14.67 ± 6.99 vs. 8.82 ± 5.90; both p < 0.001). The optimal thresholds for identifying PA were SUVmax > 5.89 and TBR > 11.5. The best ML model (LASSO) achieved an AUC of 0.811, with 79.7% accuracy and balanced sensitivity and specificity. CONCLUSIONS: Digital PET outperforms analogue system in detecting small parathyroid lesions. Additionally, ML analysis of PET-derived metrics and PTH may support non-invasive distinction between adenoma and hyperplasia.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Filippi L, Bianconi F, Ferrari C, et al. Digital versus analogue PET in parathyroid imaging: comparison of PET metrics and machine learning-based characterisation of hyperfunctioning lesions (the DIGI-PET study). Eur J Nucl Med Mol Imaging. 2025. PMID: 40844547. doi:10.1007/s00259-025-07508-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。