文献速递肿瘤 PET/CT

[68Ga]Ga-FAPI-04 PET/CT评估头颈癌放疗后涎腺损伤

[68Ga]Ga-FAPI-04 PET/CT in the evaluation of radiation-induced salivary gland injury in head and neck cancer.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-08-12

这项回顾性研究纳入63例接受头颈癌放疗后行[68Ga]Ga-FAPI-04 PET/CT的患者,建立功能正常涎腺SUV参考范围及涎腺损伤诊断标准。50例(79.4%)诊断为涎腺损伤,病灶水平检出率92.9%(91/98),阴性预测值88.1%(52/59);腮腺损伤SUVmax最佳截断值3.55(AUC 0.87;95%CI 0.80,0.94;P<0.001),灵敏度70.3%、特异度96.8%。作者认为该显像可有效提示涎腺损伤,可能成为全面检测和诊断涎腺损伤的新方法。

要点

  • 63例中50例(79.4%)放疗后诊断为涎腺损伤,病灶水平检出率92.9%(91/98)。
  • 腮腺损伤SUVmax截断值3.55时灵敏度70.3%、特异度96.8%,AUC 0.87。
  • 下颌下腺双阈值法联合下颌下腺衰减或体积缩小可将特异度从55.6%分别提高至76.7%和77.8%。

核心结论

  • [68Ga]Ga-FAPI-04 PET/CT可有效提示接受放疗的头颈癌患者的涎腺损伤,作者认为其可能成为全面检测和诊断涎腺损伤的新方法。

研究设计与样本

  • 回顾性研究,先建立功能正常涎腺的SUV参考范围并制定涎腺损伤的明确诊断标准,再回顾性分析63例接受头颈癌放疗后行[68Ga]Ga-FAPI-04 PET/CT的患者,测量腮腺与下颌下腺SUVmax,统计方法包括二元logistic回归、受试者工作特征(ROC)曲线分析和相关性分析。

主要发现

  • 63例入组患者中50例(79.4%)在放疗后诊断为涎腺损伤。
  • [68Ga]Ga-FAPI-04 PET/CT的病灶水平检出率为92.9%(91/98个病灶),阴性预测值为88.1%(52/59个病灶)。
  • 腮腺损伤诊断的SUVmax最佳截断值为3.55(AUC 0.87;95%CI 0.80,0.94;P<0.001),灵敏度70.3%、特异度96.8%。
  • 下颌下腺损伤诊断的截断值为3.15(AUC 0.74;95%CI 0.65,0.84;P<0.001),灵敏度88.6%、特异度55.6%。
  • Bootstrap校正ROC曲线与原始曲线在腮腺和下颌下腺的重叠分别为99.0%和92.1%;双阈值SUVmax法联合下颌下腺衰减或体积缩小使特异度从55.6%分别提高至76.7%(联合衰减)和77.8%(联合体积缩小),分别提升21.1和22.2个百分点。

关键数值与推荐

  • 腮腺损伤诊断的SUVmax最佳截断值为3.55(AUC 0.87;95%CI 0.80,0.94;P<0.001),灵敏度70.3%、特异度96.8%。
  • 下颌下腺损伤诊断的截断值为3.15(AUC 0.74;95%CI 0.65,0.84;P<0.001),灵敏度88.6%、特异度55.6%。
  • 双阈值SUVmax法联合下颌下腺衰减或体积缩小使特异度从55.6%分别提高至76.7%(联合衰减)和77.8%(联合体积缩小),分别提升21.1和22.2个百分点。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Radiation-induced injury to the salivary glands is a recognized complication of radiotherapy for head and neck cancer. However, comprehensive diagnosis of salivary gland dysfunction remains challenging. Therefore, we conducted a retrospective study to assess the effectiveness of [68Ga]Ga-FAPI-04 PET/CT in diagnosing salivary gland radiation injury in patients with head and neck cancer. METHODS: We initially established a reference range of SUV values for functionally normal salivary glands and developed criteria for definitively diagnosing salivary gland injury. Meanwhile, we retrospectively analyzed 63 patients who underwent [68Ga]Ga-FAPI-04 PET/CT after receiving radiotherapy for head and neck cancer. The SUVmax values of their parotid and submandibular glands were measured to assess the diagnostic value. Statistical analysis included binary logistic regression, receiver operating characteristic (ROC) curve analysis, and correlation analysis. RESULTS: Out of 63 enrolled patients, 50 (79.4%) were diagnosed with salivary gland injury after radiotherapy. [68Ga]Ga-FAPI-04 PET/CT yielded a lesion-level detection rate of 92.9% (91/98 lesions) and a negative predictive value of 88.1% (52/59 lesions). [68Ga]Ga-FAPI-04 PET/CT identified an optimal SUVmax cutoff value of 3.55(AUC, 0.87; 95% CI: 0.80, 0.94; P < 0.001) for diagnosing parotid gland injury, achieving 70.3% sensitivity and 96.8% specificity. For submandibular gland injury, the cutoff is 3.15(AUC, 0.74; 95% CI: 0.65, 0.84; P < 0.001), with a sensitivity of 88.6% and a specificity of 55.6%. The Bootstrap-adjusted ROC curves demonstrated 99.0% and 92.1% overlap with the original curves for parotid and submandibular glands. Meanwhile, the dual-threshold SUVmax approach-combined with submandibular attenuation or volume reduction-boosted specificity from 55.6 to 76.7% (+ attenuation) and 77.8% (+ volume reduction), improving performance by 21.1 and 22.2% points, respectively. CONCLUSION: The [68Ga]Ga-FAPI-04 PET/CT scan effectively indicates salivary gland injury in head and neck cancer patients undergoing radiotherapy. It may serve as a new method for comprehensive detection and diagnosis of salivary gland injury.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Yu X, Li Z, Liu Y, et al. [68Ga]Ga-FAPI-04 PET/CT in the evaluation of radiation-induced salivary gland injury in head and neck cancer. Eur J Nucl Med Mol Imaging. 2025. PMID: 40794283. doi:10.1007/s00259-025-07486-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。