镓-68 PET 显像中组织依赖性与空间可变正电子射程校正的临床评估
本研究在20例患者的[68Ga]Ga-DOTATOC或[68Ga]Ga-PSMA PET/CT数据中,对93个病灶比较了组织依赖性与空间可变正电子射程校正(TDSV PRC)、组织无关PRC及无PRC的重建图像。结果显示TDSV PRC在肺部病灶中提升SUVmax和CNR最明显,在软组织病灶中与组织无关PRC效果相似,在骨病灶中组织无关PRC的增幅略高但无统计学显著差异。
要点
- TDSV PRC在临床68Ga PET/CT数据中可行,对肺部病灶获益最大。
- 软组织病灶中TDSV PRC与组织无关PRC的SUVmax和CNR增幅相似。
- 骨病灶中组织无关PRC的SUVmax和CNR增幅略高于TDSV PRC但无统计学显著差异。
核心结论
- TDSV PRC用于68Ga PET/CT在临床患者数据中显示可行,对肺部病灶获益最大。
研究设计与样本
- 开发了利用CT驱动的不同组织类型(软组织、骨、肺)分割掩膜及相应组织特异性正电子射程核的TDSV PRC技术。
- 对20例患者的[68Ga]Ga-DOTATOC或[68Ga]Ga-PSMA PET/CT数据,采用TDSV PRC、组织无关PRC和无PRC进行OSEM重建。
- 共分析93个病灶:48个软组织病灶、35个骨病灶、10个肺病灶。
主要发现
- 软组织病灶:TDSV PRC与组织无关PRC相比无PRC的SUVmax增幅分别为13.7%(p < 0.001)与13.6%(p < 0.001),CNR增幅分别为11.0%(p < 0.001)与11.1%(p < 0.001)。
- 骨病灶:组织无关PRC相比无PRC的SUVmax增幅为18.6%(p < 0.001),TDSV PRC为17.4%(p < 0.001);CNR增幅分别为14.6%(p < 0.001)与13.8%(p < 0.001),组织无关PRC略高但无统计学显著差异。
- 肺病灶:TDSV PRC相比无PRC的SUVmax增幅为57.9%(p = 0.012),CNR增幅为43.9%(p = 0.012);相比组织无关PRC的SUVmax增幅为46.0%(p = 0.012),CNR增幅为32.5%(p = 0.012)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: Positron range correction (PRC) can mitigate the effect of the larger positron range on the image quality of Gallium-68 (68Ga) PET-imaging. The aim of this study is to evaluate the improvement in 68Ga-PET image quality by applying a tissue-dependent and spatially-variant PRC (TDSV PRC) for 68Ga in a clinical setting. METHODS: A TDSV PRC technique was developed employing CT-driven segmentation masks of different tissue types (soft tissue, bone, lung) and the corresponding tissue-specific positron range kernels. OSEM reconstructions were performed using the proposed TDSV PRC, a tissue-independent PRC, and without any PRC (non-PRC). For lesions identified in [68Ga]Ga-DOTATOC or [68Ga]Ga-PSMA PET/CT data from 20 patients, the maximum standardized uptake value (SUVmax) and contrast-to-noise ratio (CNR) of this technique was compared to tissue-independent PRC and non-PRC images. RESULTS: A total of 93 lesions were analyzed (48 soft tissue, 35 bone, 10 lung lesions). For soft tissue lesions, TDSV and tissue-independent PRC showed similar increases in SUVmax (13.7%, p < 0.001 vs. 13.6%, p < 0.001) and CNR (11.0%, p < 0.001 vs. 11.1%, p < 0.001) compared to non-PRC. For bone lesions, tissue-independent PRC showed slightly higher not statistically significant increases than TDSV PRC in SUVmax (18.6%, p < 0.001 vs. 17.4%, p < 0.001) and CNR (14.6%, p < 0.001 vs. 13.8%, p < 0.001). In lung lesions, TDSV PRC increased SUVmax and CNR compared to non-PRC (SUVmax: 57.9%, p = 0.012; CNR: 43.9%, p = 0.012) and tissue-independent PRC (SUVmax: 46.0%, p = 0.012; CNR: 32.5%, p = 0.012). CONCLUSION: TDSV PRC for 68Ga PET/CT demonstrated to be feasible in clinical patient data, showing the greatest benefits for lung lesions.
引用
- Gavriilidis P, Koole M, Mottaghy FM, et al. Clinical evaluation of tissue-dependent and spatially-variant positron range correction for Gallium-68 PET imaging. Eur J Nucl Med Mol Imaging. 2025. PMID: 40717187. doi:10.1007/s00259-025-07456-z
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。