6-脱氧-6-[18F]氟-L-抗坏血酸PET/CT以组织病理学为参考标准检测术后分化型甲状腺癌患者淋巴结转移
本研究前瞻性纳入2023年9月至11月70例甲状腺切除术后分化型甲状腺癌(DTC)患者,行[18F]FAA PET/CT并以组织病理学为金标准。患者水平准确率为92.9%(65/70),病灶水平准确率为94.3%(460/488)。淋巴结转移灶SUVmax和TBR均显著高于正常淋巴结。
要点
- [18F]FAA PET/CT检测术后DTC淋巴结转移患者水平准确率92.9%(65/70)。
- 病灶水平准确率94.3%(460/488)。
- 转移淋巴结SUVmax和TBR显著高于正常淋巴结(P<0.0001)。
核心结论
- [18F]FAA PET/CT可用于检测DTC术后颈部淋巴结转移,可能作为风险分层和放射性碘治疗决策的有价值工具。
研究设计与样本
- 前瞻性纳入2023年9月至2023年11月因DTC行甲状腺切除术、准备行131I治疗或随访检查的患者,行[18F]FAA PET/CT,以组织病理学结果为金标准。
- 共纳入70例经病理确诊的DTC患者,平均年龄40.5岁±12.0(标准差),其中男性23例。
主要发现
- 患者水平分析中,[18F]FAA PET/CT在所有患者中均检出阳性淋巴结,准确率为92.9%(65/70)。
- 对接受中央区和/或颈侧区淋巴结清扫的患者行病灶水平分析,[18F]FAA PET/CT准确率为94.3%(460/488)。
- 淋巴结转移灶SUVmax和TBR显著高于正常淋巴结(平均SUVmax 8.3±4.6 vs 2.0±1.5,P<0.0001;平均TBR 3.6±2.2 vs 0.9±0.7,P<0.0001)。
临床怎么用
- 作者认为[18F]FAA PET/CT可用于检测DTC术后颈部淋巴结转移,并可能作为风险分层和放射性碘治疗决策的有价值工具。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: 6-Deoxy-6-[ 18 F]fluoro-L-ascorbic acid ([ 18 F]FAA) is a radioisotope-labeled analogue of ascorbic acid (AA), designed to investigate oxidative stress and AA accumulation in vivo by PET imaging. It has also been reported as a promising radiotracer for tumor detection, particularly in metastatic differentiated thyroid cancer (DTC). PURPOSE: This study aimed to evaluate the diagnostic potential of [ 18 F]FAA in detecting lymph node metastases in postoperative DTC patients. METHODS: Patients who have undergone thyroidectomy for DTC and are either preparing for 131 I therapy or undergoing follow-up examinations were prospectively enrolled and underwent [ 18 F]FAA PET/CT from September 2023 to November 2023. Histopathologic results served as gold standard for final diagnosis. RESULTS: A total of 70 patients [mean age, 40.5 y±12.0 (SD); 23 men] with pathologically confirmed DTC were enrolled. At patient-based analysis, [ 18 F]FAA PET/CT detected positive lymph nodes in all patients, with an accuracy of 92.9% (65/70). At lesion-based analysis of patients who underwent central and/or lateral cervical lymph node dissection, the accuracy of [ 18 F]FAA PET/CT were 94.3% (460/488). The SUVmax and TBR of lymph node metastases were significantly higher than normal lymph nodes (mean SUVmax, 8.3±4.6 vs. 2.0±1.5, P <0.0001; mean TBR, 3.6±2.2 vs. 0.9±0.7, P <0.0001). CONCLUSIONS: [ 18 F]FAA PET/CT can be used in the detection of postoperative cervical lymph node metastases in DTC. It may serve as a valuable tool for risk stratification and radioactive iodine treatment decision-making of postoperative DTC.
引用
- Long Y, Ge S, Xu X, et al. 6-Deoxy-6-[ 18 F]Fluoro-L-Ascorbic Acid PET/CT in the Detection of Lymph Node Metastases for Postoperative Differentiated Thyroid Cancer Patients : Using Histopathology as Reference Standard. Clin Nucl Med. 2025. PMID: 40590121. doi:10.1097/RLU.0000000000006026
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。