肺部摄取量(PUV):一种新的肺PET/CT显像定量方法
该研究纳入60例放疗前(M0)和放疗结束后3个月(M3)行[68Ga]Ga-MAA PET/CT的患者,提出以解剖肺容积(ALV)和ALV内总活度归一化的肺部摄取量(PUV)指标。结果显示患者体重与ALV相关系数为0.14,SUV在ALV内波动范围0.11~22.52,PUV在用于归一化的ALV内均值等于1,且与视觉分析结果一致。
要点
- 患者体重和注射活度不适合作为肺灌注定量的归一化参数。
- 基于CT勾画的ALV和ALV内总活度归一化的PUV,在挑战性场景中与视觉分析结果一致。
- ALV内[68Ga]Ga-MAA肺滞留百分比均值58.2%(标准差7.7%),患者间及同一患者重复扫描间变异明显。
核心结论
- 患者体重和注射活度不是肺灌注定量的合适归一化参数。
- 作者提出基于配准CT计算的ALV和ALV内测得总活度归一化的肺灌注PET/CT定量指标PUV。
研究设计与样本
- 分析60例在放疗前(M0)和放疗结束后3个月(M3)行[68Ga]Ga-MAA PET/CT扫描的患者。
- 在CT上勾画解剖肺容积(ALV),将CT与PET图像配准后把ALV转移到PET图像上。
- 将每个体素测得的活度浓度(kBq/L)转换为SUV、SUVp和PUV三种指标,并测量ALV内的均值。
主要发现
- ALV内SUV均值(标准差)为9.90(5.24),数值范围不一致且宽,从0.11到22.52。
- 患者体重与ALV的相关系数为0.14。
- ALV内SUVp均值(标准差)为0.54(0.09)。
- [68Ga]Ga-MAA肺滞留百分比均值(标准差)为58.2%(7.7%),患者间及同一患者重复扫描间变异明显。
- 用于归一化的ALV内PUV均值等于1;与SUV和SUVp相比,PUV在挑战性场景中与视觉分析结果一致。
关键数值与推荐
- SUV基于测得活度按患者体重(kg)和注射剂量(kBq)归一化。
- SUVp基于测得活度按ALV(L)和注射剂量(kBq)归一化。
- PUV基于测得活度按ALV(L)和ALV内测得总活度(kBq)归一化。
临床怎么用
- 原文未据此给出临床推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: A current limitation to the use of lung PET/CT is the absence of a tool that reliably and reproducibly quantifies the intensity of tracer uptake. We aim to develop a quantitative approach for lung perfusion PET/CT imaging. Sixty patients who underwent [68Ga]Ga-MAA PET/CT scans before (M0) and 3 months (M3) after completion of radiotherapy were analyzed. The anatomical lung volume (ALV) was delineated on the CT scan. CT and PET images were co-registered, and the ALV was transferred onto the PET images. The measured activity concentration (kBq/L) in each voxel was converted in three metrics: SUV based on normalizing the measured activity to the patient's weight (kg) and the injected dose (kBq); SUVp by normalizing to the ALV (L) and the injected dose (kBq); pulmonary uptake value (PUV) by normalizing to the ALV (L) and the total activity measured in the ALV (kBq). The mean SUV, SUVp and PUV values within the ALV were measured. RESULTS: The mean (SD) SUV in the ALV was 9.90 (5.24) with an inconsistently wide range of values from 0.11 to 22.52. The correlation coefficient between the patient's weight and the ALV was 0.14. The mean (SD) SUVp in the ALV was 0.54 (0.09). The mean (SD) percentage of [68Ga]Ga-MAA lung retention was 58.2% (7.7%), with significant variability both between patients and within repeated scans of the same patient. The mean PUV in the ALV used for normalization was equal to 1. Quantitative methods were tested in challenging scenarios for quantification, including patients exhibiting decorrelation between ALV and patient's weight and patients with different percentage of [68Ga]Ga-MAA lung retention between M0 and M3. In contrast to the SUV and SUVp metrics, the PUV method showed coherent results compared to visual analysis. CONCLUSION: The patient's weight and the injected activity are not suitable parameters for normalization in lung perfusion quantification. We proposed a quantitative metric for lung perfusion PET/CT imaging, based on normalizing the measured activity to the ALV computed from a co-registered CT scan and to the total activity measured in the ALV. TRIAL REGISTRATION: NCT04942275. Registered 19 June 2021.
引用
- Le Roux PY, Le Pennec R, Bourbonne V, et al. Pulmonary uptake value (PUV): a new quantification method for lung PET/CT imaging. EJNMMI Res. 2025. PMID: 40591115. doi:10.1186/s13550-025-01274-y
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。