文献速递心脏核医学

82Rb正电子发射断层扫描心肌血流量化:动脉输入曲线质量对诊断准确性的影响

82Rb positron emission tomography myocardial blood flow quantification: Influence of arterial input curve quality on diagnostic accuracy.
PubMed 文献 · J Nucl Cardiol · 2025-06-07

该回顾性研究纳入386例无既往冠心病史、2010至2018年间接受82Rb PET心肌灌注显像及6个月内侵入性冠状动脉造影的患者,分析应激左心房血池时间-活性曲线异常形态对心肌血流诊断阻塞性冠心病(狭窄≥70%)效能的影响。低应激/静息峰值比组应激心肌血流的曲线下面积在患者水平和血管水平均低于正常组,慢活性上升组血管水平曲线下面积亦较低。结论认为低应激/静息峰值比和慢活性上升与应激心肌血流诊断效能降低相关。

要点

  • 低应激/静息峰值比组应激心肌血流AUC在患者水平为.67、血管水平为.68,均低于正常组。
  • 慢活性上升组血管水平应激心肌血流AUC为.68,低于其他组.75。
  • 其他异常曲线形态对诊断效能无显著影响。

核心结论

  • 低应激/静息峰值比和慢活性上升与应激心肌血流诊断阻塞性冠心病的效能降低相关。

研究设计与样本

  • 回顾性纳入386例无既往冠心病史、2010至2018年间接受82Rb PET心肌灌注显像及6个月内侵入性冠状动脉造影的患者。
  • 根据视觉/定量评估将应激左心房血池时间-活性曲线异常形态分为五类:低应激/静息峰值比、慢活性上升、慢活性下降、宽峰和多峰。
  • 低应激/静息峰值比定义为低于中位值0.82。
  • 采用曲线下面积分析比较应激心肌血流和心肌血流储备对阻塞性冠心病(狭窄≥70%)的诊断效能。

主要发现

  • 低应激/静息峰值比组(n=193)应激心肌血流AUC在患者水平为.67(.59-.74),正常组(n=193)为.78(.70-.84),P=.0499。
  • 低应激/静息峰值比组应激心肌血流AUC在血管水平为.68(.63-0.73),正常组为.75(.71-.79),P=.0352。
  • 慢活性上升组(n=167)血管水平应激心肌血流AUC为.68(.62-.72),其他组(n=219)为.75(.70-.79),P=.0270。
  • 其他异常曲线形态组间诊断效能无显著差异(均P>.05)。

关键数值与推荐

  • 阻塞性冠心病定义为狭窄≥70%。
  • 低应激/静息峰值比定义为应激血池峰值计数与静息血池峰值计数的比值低于中位值0.82。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: We investigated whether the shape of arterial blood input curves affects the diagnostic performance of myocardial blood flow (MBF) on rubidium-82 (82Rb) positron emission tomography (PET) myocardial perfusion imaging (MPI) for obstructive coronary artery disease (CAD). METHODS AND RESULTS: We retrospectively enrolled 386 patients without prior CAD who underwent 82Rb PET-MPI and invasive coronary angiography within 6 months, from 2010 to 2018. Abnormal shapes of stress left atrial blood pool (BP) time activity curve were characterized into five categories based on visual/quantitative assessment: (1) low stress/rest peak ratio (SRPR), (2) slow activity rise, (3) slow activity decline, (4) broad peak and (5) multiple peaks. The SRPR was defined as the ratio of peak count value on the stress BP activity by rest BP activity. A low SRPR was defined as one below the median value (0.82). We compared the diagnostic performance of stress MBF and myocardial flow reserve for detecting obstructive CAD (≥70% stenosis) using area under the curve (AUC) analysis. RESULTS: Among the five abnormal categories, the AUC of stress MBF in the low SRPR group (n = 193) was lower than in the normal SRPR group (n = 193) in per-patient (.67 [.59-.74] vs. .78 [.70-.84], P = .0499, respectively) and per-vessel analyses (.68 [.63-0.73] vs. .75 [.71-.79], P = .0352, respectively). The AUC in slow activity rise group (n = 167) for stress MBF was lower than in others in per-vessel analysis (n = 219) (.68 [.62-.72] vs. .75 [.70-.79], P = .0270). Other abnormal profiles showed no significant differences (all P > .05). CONCLUSIONS: Low SRPR and slow activity rise were associated with reduced diagnostic performance of stress MBF.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Fujito H, Lemley M, Builoff V, et al. 82Rb positron emission tomography myocardial blood flow quantification: Influence of arterial input curve quality on diagnostic accuracy. J Nucl Cardiol. 2025. PMID: 40490096. doi:10.1016/j.nuclcard.2025.102270

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。