PET-CT与CZT-SPECT测量心肌血流量和血流储备的比较:系统综述与荟萃分析
该系统综述与荟萃分析纳入8项研究共268例患者,比较PET与CZT-SPECT测量心肌血流量(MBF)和心肌血流储备(MFR)的均值差异、一致性界限及诊断效能。CZT与PET的MBF和MFR测量一致性良好但CZT略有低估,以PET为金标准时CZT-SPECT检测MBF和MFR显著降低的敏感度为80.8%、特异度为87.0%。作者认为PET因性能更优仍是首选模态,CZT在无PET可用时是可行的替代选择。
要点
- 静息和负荷MBF的PET与CZT均值差异分别为0.006(95%CI:-0.088,0.100)和0.111(95%CI:-0.418,0.195)。
- MFR的PET与CZT均值差异为0.0178(95%CI:-0.492,0.135)。
- 以PET为金标准,CZT-SPECT检测MBF和MFR显著降低的敏感度80.8%、特异度87.0%。
核心结论
- CZT测量的MBF与PET一致性良好,但CZT略有低估。
- PET因性能更优仍是首选模态,无PET可用时CZT是可行的替代选择。
- 未来研究应聚焦于标准化CZT协议。
研究设计与样本
- 系统综述与荟萃分析,检索多个数据库至2024年4月。
- 纳入8项研究,共268例患者。
- 主要结局为PET与CZT所得MBF和MFR的均值差异、一致性界限及诊断效能。
- 偏倚风险采用QUADAS-2工具评估,统计分析采用随机效应模型。
主要发现
- 静息MBF的PET与CZT均值差异为0.006(95%CI:-0.088,0.100)。
- 负荷MBF的PET与CZT均值差异为0.111(95%CI:-0.418,0.195)。
- MFR的PET与CZT均值差异为0.0178(95%CI:-0.492,0.135)。
- Bland-Altman荟萃分析示静息MBF偏倚0.05 mL/min/g(95%CI:-1.08至1.24),负荷MBF偏倚0.13 mL/min/g(95%CI:-0.969至1.228),MFR偏倚0.03 mL/min/g(95%CI:-0.999,1.006)。
- 以PET为金标准,CZT-SPECT检测MBF和MFR显著降低的敏感度为80.8%、特异度为87.0%。
关键数值与推荐
- 静息MBF的PET与CZT均值差异0.006(95%CI:-0.088,0.100)。
- 负荷MBF的PET与CZT均值差异0.111(95%CI:-0.418,0.195)。
- MFR的PET与CZT均值差异0.0178(95%CI:-0.492,0.135)。
- 静息MBF的Bland-Altman偏倚0.05 mL/min/g(95%CI:-1.08至1.24)。
- 负荷MBF的Bland-Altman偏倚0.13 mL/min/g(95%CI:-0.969至1.228),MFR偏倚0.03 mL/min/g(95%CI:-0.999,1.006)。
临床怎么用
- 作者认为PET因性能更优仍是首选模态。
- 作者认为无PET可用时CZT是可行的替代选择。
- 作者提出未来研究应聚焦于标准化CZT协议。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Myocardial blood flow (MBF) and myocardial flow reserve (MFR) measurement is crucial for diagnosing and managing coronary artery disease and microvascular dysfunction. While positron emission tomography (PET) is the gold standard, cadmium zinc telluride (CZT) is more accessible. This systematic review and meta-analysis aim to compare the accuracy, and the systematic bias of MBF and MFR measurement using CZT compared with PET. METHODS: We conducted a systematic review across multiple databases up to April 2024. The main outcomes were mean difference between MBF and MFR values obtained from PET and CZT, limits of agreement, and diagnostic performance. Risk of bias was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool and statistical analysis was conducted using random effects models. RESULTS: Eight studies, encompassing 268 patients, met the inclusion criteria. The mean difference for rest and stress myocardial blood flow between PET and CZT was .006 (95% confidence interval [CI]: -.088, .100) and .111 (95% CI: -.418, .195), respectively. The myocardial flow reserve mean difference was .0178 (95% CI: -.492, .135). Bland-Altman meta-analysis demonstrated a bias of .05 mL/min/g (95%CI: -1.08 to 1.24) for rest MBF, .13 mL/min/g for stress MBF (95%CI: -.969 to 1.228), and .03 mL/min/g (95%CI: -.999, 1.006) bias for MFR. The diagnostic performance for detecting significant reductions in MBF and MFR on single-photon emission computed tomography using PET as the gold standard demonstrated sensitivity and specificity of 80.8% and 87.0%, respectively. CONCLUSIONS: CZT MBF measurements demonstrated good agreement with PET, although they had a slight underestimation. While PET remains the preferred modality due to its superior performance, CZT represents a viable alternative when PET is unavailable. Future research should focus on standardizing CZT protocols.