文献速递肿瘤 PET/CT

基于机器学习的放射组学模型构建与验证用于预测前列腺癌ISUP分级:一项基于[68Ga]Ga-PSMA PET/CT的多中心放射组学研究

Machine learning-based construction and validation of an radiomics model for predicting ISUP grading in prostate cancer: a multicenter radiomics study based on [68Ga]Ga-PSMA PET/CT.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-06-24

本研究纳入三个中心的415例前列腺癌患者,利用[68Ga]Ga-PSMA PET/CT放射组学特征构建机器学习模型预测ISUP分级。湘雅医院训练队列最佳模型AUC为0.868(敏感度72.7%,特异度96.0%),测试队列及两个外部验证中心AUC分别为0.860、0.827和0.812;联合PSA和SUVmax后训练组AUC提升至0.892(敏感度77.9%,特异度96.0%)。

要点

  • 基于[68Ga]Ga-PSMA PET/CT的放射组学模型可无创预测前列腺癌ISUP分级。
  • 联合PSA和SUVmax后训练组AUC由0.868提升至0.892。
  • 多中心外部验证AUC分别为0.827和0.812。

原文

PURPOSE: The International Society of Urological Pathology (ISUP) grading of prostate cancer (PCa) is a crucial factor in the management and treatment planning for PCa patients. An accurate and non-invasive assessment of the ISUP grading group could significantly improve biopsy decisions and treatment planning. The use of PSMA-PET/CT radiomics for predicting ISUP has not been widely studied. The aim of this study is to investigate the role of 68Ga-PSMA PET/CT radiomics in predicting the ISUP grading of primary PCa. METHODS: This study included 415 PCa patients who underwent 68Ga-PSMA PET/CT scans before prostate biopsy or radical prostatectomy. Patients were from three centers: Xiangya Hospital, Central South University (252 cases), Qilu Hospital of Shandong University (External Validation 1, 108 cases), and Qingdao University Medical College (External Validation 2, 55 cases). Xiangya Hospital cases were split into training and testing groups (1:1 ratio), with the other centers serving as external validation groups. Feature selection was performed using Minimum Redundancy Maximum Relevance (mRMR) and Least Absolute Shrinkage and Selection Operator (LASSO) algorithms. Eight machine learning classifiers were trained and tested with ten-fold cross-validation. Sensitivity, specificity, and AUC were calculated for each model. Additionally, we combined the radiomic features with maximum Standardized Uptake Value (SUVmax) and prostate-specific antigen (PSA) to create prediction models and tested the corresponding performances. RESULTS: The best-performing model in the Xiangya Hospital training cohort achieved an AUC of 0.868 (sensitivity 72.7%, specificity 96.0%). Similar trends were seen in the testing cohort and external validation centers (AUCs: 0.860, 0.827, and 0.812). After incorporating PSA and SUVmax, a more robust model was developed, achieving an AUC of 0.892 (sensitivity 77.9%, specificity 96.0%) in the training group. CONCLUSIONS: This study established and validated a radiomics model based on 68Ga-PSMA PET/CT, offering an accurate, non-invasive method for predicting ISUP grades in prostate cancer. A multicenter design with external validation ensured the model's robustness and broad applicability. This is the largest study to date on PSMA radiomics for predicting ISUP grades. Notably, integrating SUVmax and PSA metrics with radiomic features significantly improved prediction accuracy, providing new insights and tools for personalized diagnosis and treatment.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Zhang H, Jiang X, Yang G, et al. Machine learning-based construction and validation of an radiomics model for predicting ISUP grading in prostate cancer: a multicenter radiomics study based on [68Ga]Ga-PSMA PET/CT. Eur J Nucl Med Mol Imaging. 2025. PMID: 40553115. doi:10.1007/s00259-025-07412-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。