文献速递心脏核医学放射性药物与辐射防护

衰减校正与俯卧位对心脏SPECT负荷-only显像的影响:一项观察性研究

The impact of attenuation correction and prone positioning on stress-only imaging in cardiac SPECT: An observational study.
PubMed 文献 · J Nucl Cardiol · 2025-05-20

该观察性研究纳入2018至2024年14,274例负荷SPECT心肌灌注显像无灌注缺损患者,评估俯卧位与CT衰减校正(AC)对减少额外静息显像需求的作用。同时使用俯卧位和AC时负荷-only显像比例从43.6%升至76%,放射性示踪剂剂量降低35.6%,且负荷-only正常者预后与负荷-静息显像正常者相似。

要点

  • 同时使用俯卧位和AC使负荷-only显像比例从43.6%升至76%,多变量logistic回归OR为5.0(95%CI 4.38-5.72)。
  • 同时使用AC和俯卧位时放射性示踪剂剂量降低35.6%。
  • 负荷-only SPECT正常者预后与负荷-静息显像正常者相似,与是否使用AC或俯卧位无关。

核心结论

  • 同时使用AC和俯卧位使额外静息显像需求减少近一半,放射性示踪剂剂量降低三分之一。
  • 获益在女性、肥胖患者、65岁以上患者、非糖尿病患者及射血分数保留患者中更明显。

研究设计与样本

  • 观察性研究,连续纳入2018至2024年负荷SPECT心肌灌注显像无灌注缺损的患者共14,274例。
  • 根据是否使用俯卧位和AC评估额外静息显像需求,放射性示踪剂剂量按本机构方案计算并在组间比较,采用生存分析比较负荷-only方案与负荷-静息方案的安全性。

主要发现

  • 负荷-only显像使用率从既无AC也无俯卧位的43.6%升至仅AC的63.4%、仅俯卧位的65.7%、两者均用的76%。
  • 多变量logistic回归显示同时使用俯卧位和AC显著增加负荷-only显像(OR 5.0,95%CI 4.38-5.72)。
  • 同时使用AC和俯卧位时放射性示踪剂剂量降低35.6%。
  • 负荷-only SPECT正常者预后与负荷-静息显像正常者相似,与是否使用AC或俯卧位无关。

关键数值与推荐

  • 当前指南推荐在特定患者中采用负荷-only SPECT心肌灌注显像以减少时间、费用和辐射,但负荷-only显像仍未充分利用。
  • 同时使用俯卧位和AC时负荷-only显像比例为76%,OR为5.0(95%CI 4.38-5.72)。
  • 同时使用AC和俯卧位时放射性示踪剂剂量降低35.6%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Current guidelines recommend stress-only single photon emission computed tomography myocardial perfusion imaging (SPECT MPI) in select patients to reduce time, cost, and radiation. However, stress-only imaging remains underutilized. OBJECTIVES: We assessed techniques to increase the adoption of stress-only SPECT MPI, specifically evaluating whether prone positioning and CT-based attenuation correction (AC) reduce the need for additional rest imaging. METHODS: Consecutive patients with normal stress SPECT MPI scans were included. The need for additional rest imaging was assessed according to the use of prone positioning and AC. Radiotracer dose was calculated per the institution's protocol and compared between groups. Survival analysis compared the safety of stress-only protocols to stress-rest protocols. RESULTS: Between 2018 and 2024, 14,274 patients with no stress perfusion defects were included. The use of stress-only imaging increased from 43.6% among patients with neither AC nor prone to 63.4% with AC and 65.7% with prone to 76 % with both techniques. Using multivariable logistic regression, the simultaneous use of prone and AC techniques significantly increased stress-only imaging (OR: 5.0, 95% CI: 4.38-5.72). This was more pronounced among females, obese patients, patients >65 years, and patients with an EF ≥ 55%. Radiotracer dose dropped by 35.6% when both AC and prone were used. Patients with normal stress-only SPECT scans had similar prognoses to those with normal SPECT scans using both stress and rest images, regardless of AC or prone imaging use. CONCLUSION: Combined use of AC and prone reduces the need for rest imaging by nearly half and lowers radiotracer doses by a third. Benefits are more pronounced in women, the elderly, patients with obesity, non-diabetics, and those with preserved ejection fraction.

来源:J Nucl Cardiol,查看原文。版权归原作者所有。

引用

  1. Alwan M, Sayed A, Ahmed AI, et al. The impact of attenuation correction and prone positioning on stress-only imaging in cardiac SPECT: An observational study. J Nucl Cardiol. 2025. PMID: 40403958. doi:10.1016/j.nuclcard.2025.102249

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。