文献速递肿瘤 PET/CT心脏核医学神经核医学

高时间分辨率早期动态18F-FDG PET动力学建模定量全身血流成像

Quantitative Total-Body Imaging of Blood Flow with High-Temporal-Resolution Early Dynamic 18F-FDG PET Kinetic Modeling.
PubMed 文献 · J Nucl Med · 2025-06-02

本研究开发了高时间分辨率早期动态18F-FDG PET动力学建模方法,直接估计全身血流,并与11C-丁醇血流示踪剂进行对照。6名受试者同体比较显示两者定量一致(相关系数0.955,P<0.001),另34名健康受试者结果与已发表血流范围大致相符,表明该方法可行。

要点

  • 早期动态18F-FDG PET高时间分辨率动力学建模可定量全身血流。
  • 与11C-丁醇同体区域测量定量一致,相关系数0.955(P<0.001)。
  • 高时间分辨率(1-2秒/帧)为AATH建模所必需。

核心结论

  • 采用高时间分辨率动力学建模的早期动态18F-FDG PET进行全身血流成像可行。
  • 该方法可与标准18F-FDG PET方法结合,实现高效单示踪剂多参数血流-代谢成像,在肿瘤学、心血管疾病、疼痛医学和神经科学中有诸多研究和临床应用。

研究设计与样本

  • 本研究为方法开发及初步对照研究,分析6名接受18F-FDG和11C-丁醇全身动态PET扫描的人体受试者图像。
  • 另分析34名健康受试者的全身动态18F-FDG PET图像,与已发表血流范围比较。
  • 早期动态PET前2分钟以高时间分辨率重建(60×1秒/帧,30×2秒/帧)。
  • 采用分布式动力学模型(组织均匀性绝热近似[AATH]模型)直接估计血流,并与标准隔室模型拟合用Akaike信息准则在不同时间分辨率下比较。

主要发现

  • 18F-FDG血流与11C-丁醇血流在同体区域测量中定量一致:Pearson相关系数0.955(P<0.001),线性回归斜率和截距分别为0.973和-0.012。
  • 健康队列 cerebral cortex 血流值为0.51±0.12 mL/min/cm3,肺部为2.03±0.64 mL/min/cm3,与已发表范围大致相符。
  • AATH建模需要高时间分辨率(1-2秒/帧)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

Past efforts to measure blood flow with the widely available radiotracer 18F-FDG were limited to tissues with high 18F-FDG extraction fraction. In this study, we developed an early dynamic 18F-FDG PET method with high-temporal-resolution (HTR) kinetic modeling to assess total-body blood flow based on deriving the vascular phase of 18F-FDG transit and conducted a pilot comparison study against a 11C-butanol flow-tracer reference. Methods: The first 2 min of dynamic PET scans were reconstructed at HTR (60 × 1 s/frame, 30 × 2 s/frame) to resolve the rapid passage of the radiotracer through blood vessels. In contrast to existing methods that use blood-to-tissue transport rate as a surrogate of blood flow, our method directly estimated blood flow using a distributed kinetic model (adiabatic approximation to tissue homogeneity [AATH] model). To validate our 18F-FDG measurements of blood flow against a reference flow-specific radiotracer, we analyzed total-body dynamic PET images of 6 human participants scanned with both 18F-FDG and 11C-butanol. An additional 34 total-body dynamic 18F-FDG PET images of healthy participants were analyzed for comparison against published blood-flow ranges. Regional blood flow was estimated across the body, and total-body parametric imaging of blood flow was conducted for visual assessment. AATH and standard compartment model fitting was compared using the Akaike information criterion at different temporal resolutions. Results: 18F-FDG blood flow was in quantitative agreement with flow measured from 11C-butanol across same-subject regional measurements (Pearson correlation coefficient, 0.955; P < 0.001; linear regression slope and intercept, 0.973 and -0.012, respectively), which was visually corroborated by total-body blood-flow parametric imaging. Our method resolved a wide range of blood-flow values across the body in broad agreement with published ranges (e.g., healthy cohort values of 0.51 ± 0.12 mL/min/cm3 in the cerebral cortex and 2.03 ± 0.64 mL/min/cm3 in the lungs). HTR (1-2 s/frame) was required for AATH modeling. Conclusion: Total-body blood-flow imaging was feasible using early dynamic 18F-FDG PET with HTR kinetic modeling. This method may be combined with standard 18F-FDG PET methods to enable efficient single-tracer multiparametric flow-metabolism imaging, with numerous research and clinical applications in oncology, cardiovascular disease, pain medicine, and neuroscience.

来源:J Nucl Med,查看原文。版权归原作者所有。

引用

  1. Chung KJ, Chaudhari AJ, Nardo L, et al. Quantitative Total-Body Imaging of Blood Flow with High-Temporal-Resolution Early Dynamic 18F-FDG PET Kinetic Modeling. J Nucl Med. 2025. PMID: 40306973. doi:10.2967/jnumed.124.268706

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。