用于诊断转甲状腺素蛋白心脏淀粉样变性的定量SPECT/CT指标:基于活检确诊案例的多中心研究
这项多中心回顾性研究纳入253例接受[99mTc]Tc-PYP SPECT/CT的患者,在活检结果可用的52例中评估侧壁/主动脉(LW/Ao)比值诊断转甲状腺素蛋白心脏淀粉样变性(ATTR-CM)的效能。LW/Ao比值灵敏度100%(11/11)、特异度97.6%(40/41)、阳性似然比41.0,AUC 0.99(95%CI 0.99-1.00),高于H/CL比值(AUC=0.90,p=0.04)和视觉评分(AUC=0.87,p<0.01),组内相关系数为0.91。
要点
- LW/Ao比值诊断ATTR-CM灵敏度100%(11/11)、特异度97.6%(40/41)、阳性似然比41.0。
- LW/Ao比值AUC 0.99(95%CI 0.99-1.00),高于H/CL比值(AUC=0.90,p=0.04)和视觉评分(AUC=0.87,p<0.01)。
- LW/Ao比值的组内相关系数为0.91,观察者间一致性优秀。
核心结论
- 定量SPECT/CT指标LW/Ao比值对ATTR-CM的诊断准确性优于常规方法。
研究设计与样本
- 多中心回顾性研究,纳入253例于2021年4月至2024年9月期间接受[99mTc]Tc-PYP SPECT/CT的患者。
- SPECT/CT在注射740 MBq [99mTc]Tc-PYP后3小时采集。
- LW/Ao比值由左心室侧壁平均放射性计数除以升主动脉平均计数获得。
- ATTR-CM诊断由心内膜心肌活检确定;52例有活检结果的患者中11例诊断为ATTR-CM。
主要发现
- LW/Ao比值灵敏度100%(11/11)、特异度97.6%(40/41)、阳性似然比41.0。
- LW/Ao比值AUC 0.99(95%CI 0.99-1.00),高于H/CL比值(AUC=0.90,p=0.04)。
- LW/Ao比值AUC高于视觉评分(AUC=0.87,p<0.01)。
- LW/Ao比值的组内相关系数为0.91,观察者间一致性优秀。
关键数值与推荐
- LW/Ao比值诊断ATTR-CM的灵敏度为100%(11/11)、特异度为97.6%(40/41)、阳性似然比为41.0。
- LW/Ao比值AUC为0.99(95%CI 0.99-1.00),H/CL比值AUC为0.90(p=0.04),视觉评分AUC为0.87(p<0.01)。
- LW/Ao比值组内相关系数为0.91。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: 99mTechnetium-pyrophosphate ([99mTc]Tc-PYP) scintigraphy is the gold standard for diagnosing transthyretin amyloid cardiomyopathy (ATTR-CM). Conventional metrics, such as heart-to-contralateral-chest (H/CL) ratio and visual Perugini score, can be influenced by physiological blood pool uptake, leading to false positives and additional patient burdens. This study aimed to develop and validate a simple quantitative metric widely applicable for ATTR-CM diagnosis. METHODS: This multicenter retrospective study enrolled 253 patients who underwent [99mTc]Tc-PYP SPECT/CT between April 2021 and September 2024. SPECT/CTs were acquired 3 h post-injection of 740 MBq [99mTc]Tc-PYP. A lateral wall-to-aorta (LW/Ao) ratio was obtained by dividing the average radiotracer count in the lateral wall of the left ventricle by the average count in the ascending aorta. The diagnosis of ATTR-CM diagnosis was determined by endomyocardial biopsy. As statistical analyses, area under receiver operating characteristic (AUC) was used to compare diagnostic accuracy, and intraclass correlation coefficient (ICC) was used to assess inter-rater agreement. RESULTS: Among 52 patients (31 men; mean age 77) whose biopsy results were available, 11 were diagnosed with ATTR-CM. LW/Ao ratio showed a sensitivity of 100% (11/11), specificity of 97.6% (40/41), and positive likelihood ratio of 41.0. LW/Ao ratio showed higher AUC (0.99; 95% CI: 0.99-1.00) compared to H/CL ratio (AUC = 0.90, p = 0.04) and visual score (AUC = 0.87, p < 0.01). The ICC of LW/Ao ratio was excellent (0.91 ≥ 0.9). CONCLUSION: The quantitative SPECT/CT metric demonstrated superior diagnostic accuracy for ATTR-CM compared to conventional methods.
引用
- Takaishi T, Kisohara M, Horino R, et al. A quantitative SPECT/CT metric for diagnosing transthyretin cardiac amyloidosis: multicenter study on biopsy-confirmed cases. Eur J Nucl Med Mol Imaging. 2025. PMID: 40272501. doi:10.1007/s00259-025-07294-z