基于深度学习虚拟衰减校正图重建的锝-99m甲氧基异丁基异腈CZT-SPECT按冠状动脉供血区评估并与铷-82 PET对比
本研究在84例存在衰减伪影风险(超重个体和女性)、无冠心病史的患者中,比较标准重建与深度学习衰减校正(DLAC)重建的负荷-静息[99mTc]甲氧基异丁基异腈CZT-SPECT,并与[82Rb]铷PET对比。在74例冠心病极低风险患者中,DLAC-SPECT使右冠状动脉供血区负荷节段活性与铷PET一致,而标准SPECT该区域活性明显降低。
要点
- 标准SPECT右冠状动脉供血区负荷节段活性69.1%±8.2%,低于DLAC-SPECT的81.2%±7.1%和铷PET的77.7%±8.5%(均P<.001)。
- 右冠状动脉供血区静息-负荷节段活性差值绝对值标准SPECT为5.13%±4.04%,高于DLAC-SPECT的4.21%±3.24%和铷PET的3.92%±3.08%(均P<.001)。
- DLAC-SPECT三个冠状动脉供血区负荷节段活性均匀,与铷PET结果一致。
核心结论
- 使用DLAC图重建[99mTc]甲氧基异丁基异腈CZT-SPECT时,右冠状动脉供血区摄取不再下降,负荷-静息活性波动更小,与同一患者铷PET结果高度一致。
研究设计与样本
- 研究纳入84例存在衰减伪影风险(超重个体和女性)、无冠心病史的患者,比较标准重建SPECT与DLAC重建SPECT,并均行铷PET及必要时的冠状动脉造影。
主要发现
- 在74例冠心病极低风险患者中,DLAC-SPECT与铷PET三个冠状动脉供血区负荷节段活性均匀,而标准SPECT右冠状动脉供血区明显降低(69.1%±8.2% vs DLAC-SPECT 81.2%±7.1%和铷PET 77.7%±8.5%,均P<.001)。
- 右冠状动脉供血区静息-负荷节段活性差值绝对值标准SPECT为5.13%±4.04%,高于DLAC-SPECT的4.21%±3.24%和铷PET的3.92%±3.08%(均P<.001)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Attenuation artifacts affect the analysis of single-photon emission computed tomography (SPECT) myocardial perfusion imaging, especially in the right coronary artery (RCA) territory, although computed tomography (CT)-based attenuation corrections minimize this issue. This study aims to assess stress-rest [99mTc]sestamibi cadmium zinc telluride (CZT)-SPECT reconstructed using deep-learning-based attenuation correction (DLAC) maps according to coronary artery territory and with comparison to [82Rb]rubidium-positron emission tomography (Rb-PET) conventionally reconstructed with CT-based attenuation correction. METHODS: We compared stress-rest [99mTc]sestamibi CZT-SPECT reconstructed without (i.e., standard (SD-SPECT)) and with DLAC (DLAC-SPECT) in 84 patients at risk of attenuation artifacts (overweight individuals and women) with no previous history of coronary artery disease (CAD), and who also had Rb-PET and, when indicated, coronary angiography. RESULTS: In 74 very low CAD-risk patients: (i) the stress segmental activity values were homogeneous between the three coronary artery territories with DLAC-SPECT and Rb-PET but exhibited a marked reduction in the RCA territory with SD-SPECT (69.1% ± 8.2% vs 81.2% ± 7.1% and 77.7% ± 8.5% for DLAC-SPECT and Rb-PET, respectively, both P < .001), and (ii) the absolute value of the difference between the rest and stress segmental activities was higher in the RCA territory with SD-SPECT (5.13% ± 4.04%) than with DLAC-SPECT (4.21% ± 3.24%) and Rb-PET (3.92% ± 3.08%, both P < .001). CONCLUSIONS: When utilizing DLAC maps for reconstruction of [99mTc]sestamibi CZT-SPECT, there is no more drop in the RCA territory uptake with lower fluctuations in stress-to-rest activity, aligning closely with the results observed using Rb-PET in the same patients. TRIAL REGISTRATION NUMBER: NCT01679886 on clinicaltrials.gov.
引用
- Sprauel T, Imbert L, Doyeux K, et al. Assessment of sestamibi CZT-SPECT reconstructed using deep-learning-based virtual attenuation correction maps according to coronary artery territory and with comparison to rubidium-PET. J Nucl Cardiol. 2025. PMID: 40258438. doi:10.1016/j.nuclcard.2025.102226
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。