文献速递心脏核医学

基于心肌灌注显像的无极图三维深度学习模型预测阻塞性冠状动脉疾病的跨机构验证:泛化性与偏倚的洞察

Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-04-08

本研究在台湾两家医学中心回顾性纳入接受负荷/再分布铊-201心肌灌注显像(MPI)并于90天内行有创冠状动脉造影的患者,用一家中心928幅MPI图像训练的无极图三维深度学习模型预测阻塞性冠状动脉疾病(CAD),在内部验证集(933幅)和外部验证集(3234幅)上测试。模型在外部队列的基于患者(AUC 0.713 vs 0.813)和基于血管(AUC 0.733 vs 0.782)分析中性能均显著低于内部队列,但仍优于负荷总灌注缺损(TPD)(均P<0.001)。内部队列中接受平板运动负荷MPI的患者及外部队列中70岁以上患者性能较低,提示模型泛化性有限且存在与负荷类型和年龄相关的偏倚。

要点

  • 模型外部队列基于患者AUC 0.713、基于血管AUC 0.733,均低于内部队列的0.813和0.782。
  • 模型在内部和外部队列中均优于负荷TPD(均P<0.001)。
  • 内部队列平板运动负荷MPI患者及外部队列70岁以上患者性能较低。

核心结论

  • 基于MPI的深度学习模型性能尚可,但跨机构泛化性有限,并存在与负荷类型和患者年龄相关的偏倚。
  • 在临床实施深度学习MPI模型前,充分的验证至关重要。

研究设计与样本

  • 回顾性纳入台湾两家医学中心接受负荷/再分布铊-201 MPI并于90天内行有创冠状动脉造影作为参考标准的患者。
  • 在一家中心928幅MPI图像上训练无极图三维深度学习模型预测阻塞性CAD,在内部验证集933幅和外部验证集3234幅(来自另一中心)上测试。

主要发现

  • 外部队列基于患者分析AUC为0.713,低于内部队列的0.813;基于血管分析AUC为0.733,低于内部队列的0.782。
  • 模型在内部和外部队列中均优于负荷TPD(均P<0.001)。
  • 内部队列中接受平板运动负荷MPI的患者性能较低。
  • 外部队列中70岁以上患者性能较低。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 本研究表明深度学习MPI模型泛化性有限,并存在与负荷类型和患者年龄相关的偏倚。
  • 在临床实施深度学习MPI模型前,充分的验证至关重要。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Deep learning (DL) models for predicting obstructive coronary artery disease (CAD) using myocardial perfusion imaging (MPI) have shown potential for enhancing diagnostic accuracy. However, their ability to maintain consistent performance across institutions and demographics remains uncertain. This study aimed to investigate the generalizability and potential biases of an in-house MPI DL model between two hospital-based cohorts. METHODS: We retrospectively included patients from two medical centers in Taiwan who underwent stress/redistribution thallium-201 MPI followed by invasive coronary angiography within 90 days as the reference standard. A polar map-free 3D DL model trained on 928 MPI images from one center to predict obstructive CAD was tested on internal (933 images) and external (3234 images from the other center) validation sets. Diagnostic performance, assessed using area under receiver operating characteristic curves (AUCs), was compared between the internal and external cohorts, demographic groups, and with the performance of stress total perfusion deficit (TPD). RESULTS: The model showed significantly lower performance in the external cohort compared to the internal cohort in both patient-based (AUC: 0.713 vs. 0.813) and vessel-based (AUC: 0.733 vs. 0.782) analyses, but still outperformed stress TPD (all p < 0.001). The performance was lower in patients who underwent treadmill stress MPI in the internal cohort and in patients over 70 years old in the external cohort. CONCLUSIONS: This study demonstrated adequate performance but also limitations in the generalizability of the DL-based MPI model, along with biases related to stress type and patient age. Thorough validation is essential before the clinical implementation of DL MPI models.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Shih YC, Ko CL, Wang SY, et al. Cross-institutional validation of a polar map-free 3D deep learning model for obstructive coronary artery disease prediction using myocardial perfusion imaging: insights into generalizability and bias. Eur J Nucl Med Mol Imaging. 2025. PMID: 40198356. doi:10.1007/s00259-025-07243-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。