人工智能可能有助于基于[18F]FDG PET/CT的影像组学特征预测甲状腺结节恶性
研究纳入50例因[18F]FDG局灶性摄取增高而接受细针穿刺活检的甲状腺偶发瘤患者,其中11例(22.0%)诊断为恶性。基于影像组学特征的XGBoost模型评估恶性度的曲线下面积为0.846(95%CI 0.737-0.956),与SUVmax的0.797(95%CI 0.622-0.973)相似,差异无统计学意义(p=0.60)。
要点
- 在50例[18F]FDG局灶性摄取的甲状腺偶发瘤患者中,11例(22.0%)为恶性。
- 影像组学XGBoost模型曲线下面积为0.846(95%CI 0.737-0.956)。
- XGBoost模型与SUVmax的曲线下面积(0.797,95%CI 0.622-0.973)无统计学显著差异(p=0.60)。
核心结论
- 基于影像组学特征的人工智能算法可能检出甲状腺结节的恶性,但人工智能与影像组学方法之间、以及与常规指标SUVmax之间均未观察到统计学显著差异。
研究设计与样本
- 研究分析了54例表现为[18F]FDG局灶性摄取增高并随后接受细针穿刺活检的甲状腺偶发瘤患者,其中4例因缺乏最终诊断信息被排除,最终分析纳入50例患者(39例女性、11例男性,平均年龄58.5±11.26岁)。
主要发现
- 50例患者中,11例(22.0%)[18F]FDG摄取增高的结节被诊断为恶性。
- XGBoost模型评估[18F]FDG摄取增高的甲状腺偶发瘤的曲线下面积为0.846(95%CI 0.737-0.956),SUVmax为0.797(95%CI 0.622-0.973),两者比较p=0.60。
关键数值与推荐
- XGBoost模型评估甲状腺偶发瘤恶性度的曲线下面积为0.846(95%CI 0.737-0.956)。
- SUVmax评估甲状腺偶发瘤恶性度的曲线下面积为0.797(95%CI 0.622-0.973)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: The number of thyroid cancer diagnoses has been increasing for several decades, with a significant part of cases being detected incidentally (thyroid incidentaloma, TI) by imaging studies performed for reasons other than thyroid disease, including PET/CT with [18F]FDG. The chacteristics of the detected TI cannot be determined solely on the basis of conventional parameters used in everyday clinical practice, such as SUVmax. In recent years, there has been a growing interest in radiomics, which is a quantitative method of analyzing radiological images based on the analysis of image texture. Textural analysis may be helpful, as it allows to characterize features invisible to the physician with the naked eye. RESULTS: Of the 54 patients who presented focal [18F]FDG-avid TI and had subsequent fine needle aspiration biopsy, 4 patients were excluded from the analysis due to the unavailability of the final diagnostic information. Hence, in the final analysis, data from 50 patients were used (39 females and 11 males) with a mean age of 58.5 ± 11.26. Of these 50 patients, 11 (22.0%) [18F]FDG-avid nodules were diagnosed as malignant. The performance of the XGBoost model in assessing [18F]FDG-avid TI was similar (0.846 [confidence interval, CI, 95% 0.737-0.956]) to SUVmax (0.797 [CI 95%: 0.622-0.973]; p = 0.60). CONCLUSIONS: With an AI-based algorithm using radiomics features it is possible to detect the malignancy of thyroid nodule. However, no statistically significant differences were observed between the AI and radiomics approach, and when using a conventional measure, i.e., SUVmax.
引用
- Ślusarz K, Buchwald M, Szczeszek A, et al. AI may help to predict thyroid nodule malignancy based on radiomics features from [18F]FDG PET/CT. EJNMMI Res. 2025. PMID: 40214892. doi:10.1186/s13550-025-01228-4
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。