68Ga-FAPI与18F-FAPI PET/CT在高危尿路上皮癌患者根治性膀胱切除术前检测淋巴结转移
本研究纳入51例高危尿路上皮癌患者,在根治性膀胱切除与前哨淋巴结清扫术前分别接受68Ga-FAPI-46(n=23)或18F-FAPI-74(n=28)PET/CT,以病理为金标准评估区域淋巴结转移。FAPI PET视觉分析灵敏度高于CT,18F-FAPI-74与68Ga-FAPI-46诊断性能相当;定量分析采用预设SUVmax等切点较视觉分析提供更高灵敏度。
要点
- FAPI PET/CT对尿路上皮癌区域淋巴结转移的视觉分析灵敏度高于CT视觉分析。
- 18F-FAPI-74与68Ga-FAPI-46的视觉分析诊断性能相当。
- 定量分析采用SUVmax等切点较视觉分析提供更高灵敏度。
核心结论
- 总体而言,FAPI PET显像检测尿路上皮癌区域淋巴结转移的灵敏度显著高于CT分析。
- 18F-FAPI-74与68Ga-FAPI-46诊断性能相当。
- 采用预设SUVmax、SUVmean及SUVmax_淋巴结/SUVmean_背景比值切点的定量分析较视觉评估提供更高灵敏度。
研究设计与样本
- 51例患者根治性膀胱切除与前哨淋巴结清扫术前接受FAPI PET/CT,其中68Ga-FAPI-46组23例、18F-FAPI-74组28例。
- 评估SUVmax、SUVmean及淋巴结SUVmax与背景SUVmean比值,并记录每个淋巴结区域代表性淋巴结短轴直径(共123个淋巴结区域),与组织病理学对照。
- 每份扫描进行视觉与定量判读,采用ROC分析确定最高诊断准确度的切点值。
主要发现
- 123个淋巴结区域中20个(16.3%)显示尿路上皮癌淋巴结转移。
- 组织病理学阳性淋巴结的FAPI摄取在SUVmax、SUVmean及SUVmax_淋巴结/SUVmean_背景比值上均显著高于阴性淋巴结。
- 视觉分析基于FAPI摄取:68Ga-FAPI-46灵敏度63.6%、特异度95.8%、PPV 77.7%、NPV 92.0%;18F-FAPI-74灵敏度55.5%、特异度98.1%、PPV 83.3%、NPV 93.1%。
- CT视觉分析区域淋巴结:灵敏度30.0%、特异度97.0%、PPV 66.6%、NPV 87.7%。
- 短轴直径ROC分析切点0.8 cm:灵敏度75.0%、特异度84.4%、PPV 48.3%、NPV 94.5%。
关键数值与推荐
- 68Ga-FAPI-46鉴别病理证实的淋巴结转移与良性淋巴结的ROC最佳切点:SUVmax 1.35、SUVmean 1.20、SUVmax_淋巴结/SUVmean_背景比值5.95。
- 18F-FAPI-74鉴别病理证实的淋巴结转移与良性淋巴结的ROC最佳切点:SUVmax 1.55、SUVmean 1.25、SUVmax_淋巴结/SUVmean_背景比值4.15。
- 以SUVmax切点为例,68Ga-FAPI-46灵敏度81.8%、特异度89.5%、PPV 64.2%、NPV 95.5%;18F-FAPI-74灵敏度100%、特异度81.8%、PPV 47.3%、NPV 100%。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
INTRODUCTION: To determine the best therapeutic strategy for muscle-invasive bladder cancer (BC), the accuracy of lymph node staging is of paramount importance. However, diagnostic performance of conventional computed tomography in BC prior to radical cystectomy (RC) remains unsatisfactory. There is an increased interest in evaluating 18F-FAPI PET/CT for hybrid imaging due to their logistical advantages compared to [68Ga]Ga-based FAPI tracers in clinical routine. Recently, the potential diagnostic value of [68Ga]Ga-FAPI- 46 PET/CT was demonstrated in BC. Thus, we aimed to examine the diagnostic performance of [18F]F-FAPI- 74 and [68Ga]Ga-FAPI- 46 PET/CT for preoperative evaluation of locoregional lymph node metastases. METHODS: Fifty-one patients underwent FAPI PET/CT with either [68Ga]Ga-FAPI- 46 (n = 23) or [18F]F-FAPI- 74 (n = 28) prior to RC and PLND. SUVmax, SUVmean and the ratio between the SUVmax of lymph nodes and the SUVmean of the background (SUVmax_lymph node/SUVmean_background) were assessed. Additionally, short axis diameter (SAD) for a representative lymph node were documented in each lymph node region (n = 123) and compared to histopathological findings. Each scan was interpreted visually and quantitatively. ROC-analyses were performed to determine cut-off values with highest diagnostic accuracy. RESULTS: 20/123 (16.3%) lymph node regions showed UC lymph node metastases. Histopathologically positive lymph nodes were associated with a significantly higher FAPI uptake compared to negative lymph nodes regarding SUVmax, SUVmean values and SUVmax_lymph node/SUVmean_background ratios. Visual analysis based on FAPI uptake showed a sensitivity and specificity, PPV and NPV of 63.6%, 95.8%, 77.7%, and 92.0% for [68Ga]Ga-FAPI- 46 and 55.5%, 98.1%, 83.3%, and 93.1% for [18F]F-FAPI- 74, respectively. ROC analysis revealed an optimal cut-off for SUVmax, SUVmean and SUVmax_lymph node/SUVmean_background of 1.35, 1.20 and 5.95 for [68Ga]Ga-FAPI- 46 and 1.55, 1.25 and 4.15 for [18F]F-FAPI- 74 to discriminate between histopathologically proven lymph node metastases and non-malignant lymph nodes resulting for example using SUVmax in a sensitivity and specificity, PPV and NPV of 81.8%, 89.5%, 64.2%, 95.5% for [68Ga]Ga-FAPI- 46 and 100%, 81.8%, 47.3%, 100% for [18F]F-FAPI- 74, respectively. CT visual analysis of locoregional lymph nodes showed a sensitivity, specificity, PPV and NPV of 30.0%, 97.0%, 66.6% and 87.7%, respectively. ROC analysis regarding SAD revealed a cutoff at 0.8 cm with a sensitivity, specificity, PPV and NPV of 75.0%, 84.4%, 48.3%, 94.5%, respectively. CONCLUSION: Overall, FAPI PET imaging shows a significantly higher sensitivity than CT analysis for detection of locoregional lymph node metastases in UC. [18F]F-FAPI- 74 demonstrates a comparable diagnostic performance compared to [68Ga]Ga-FAPI- 46. Of note, the quantitative analysis with a pre-defined SUVmax as well as SUVmean values, and SUVmax_lymph node/SUVmean_background ratio-based cut-offs provided a higher sensitivity compared to visual assessment.
引用
- Unterrainer LM, Schmid HP, Kunte SC, et al. 68Ga-FAPI and 18F-FAPI PET/CT for detection of nodal metastases prior radical cystectomy in high-risk urothelial carcinoma patients. Eur J Nucl Med Mol Imaging. 2025. PMID: 40272498. doi:10.1007/s00259-025-07239-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。