基于标准化摄取值对已知或疑似炎性关节炎患者的高速度360°CZT相机两相全身骨断层显像分析
本研究纳入72例已知或疑似炎性关节炎患者,行两相全身骨SPECT/CT,比较SUVmax与视觉判读对炎性关节炎的检测效能。结果显示SUVmax阈值预测视觉异常SPECT的阴性预测值高(血池相99.2%,延迟相97.2%),但阳性预测值低;MRI和US定义的炎性关节炎最好由视觉异常血池相SPECT预测。作者认为SUVmax检测不能替代传统视觉方法,但可仅对超过阈值的少数关节进行视觉分析。
要点
- SUVmax阈值预测视觉异常SPECT的阴性预测值高,血池相99.2%,延迟相97.2%。
- SUVmax阈值预测视觉异常SPECT的阳性预测值低,血池相35.1%,延迟相51.2%。
- MRI和US定义的炎性关节炎最好由视觉异常血池相SPECT预测,特异性高于SUVmax阈值(均p<0.05)。
核心结论
- 在两相全身骨SPECT/CT中,基于SUVmax的炎性关节炎检测可能不能替代传统视觉方法。
- 鉴于SUVmax阈值提供的高阴性预测值,耗时SPECT/CT层面的视觉分析可限于超过这些阈值的少数关节。
研究设计与样本
- 纳入72例已知或疑似炎性关节炎患者,注射550-650 MBq [99mTc]Tc-HDP后行两相全身骨SPECT/CT。
- 48例患者另接受超声检查外周炎性关节炎,42例患者另接受MRI检查中轴炎性关节炎。
- 骨骼分割为26个关节区域,由受训观察者采用视觉共识方法和SUVmax测量进行分析。
主要发现
- 共分析1836个关节区域,其中1126个为外周关节区域(四肢关节,不包括髋和肩)。
- SUVmax预测视觉异常SPECT关节的ROC曲线下面积:非外周关节血池相SPECT为0.941±0.017,延迟相SPECT为0.910±0.014;外周关节血池相SPECT为0.980±0.005,延迟相SPECT为0.939±0.012。
- 基于SUVmax阈值的视觉SPECT异常预测阴性预测值:血池相SPECT为99.2%(1479/1491),延迟相SPECT为97.2%(1333/1372)。
- 基于SUVmax阈值的视觉SPECT异常预测阳性预测值:血池相SPECT为35.1%(121/345),延迟相SPECT为51.2%(237/463)。
- MRI和US定义的炎性关节炎最好由视觉异常血池相SPECT预测,因其特异性高于SUVmax阈值(均p<0.05)。
临床怎么用
- 作者认为,基于SUVmax的炎性关节炎检测可能不能替代传统视觉方法。
- 作者认为,鉴于SUVmax阈值提供的高阴性预测值,耗时SPECT/CT层面的视觉分析可限于超过这些阈值的少数关节。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: 360° CZT-cameras provide whole-body bone SPECT/CT recordings at delayed (DEL) and blood-pool (BP) phases with short recording times but long visual analysis times. This study aims to determine whether a standardized uptake value (SUV)-based detection of inflammatory arthritis (IA) could facilitate this analysis. METHODS: We included 72 patients with known or suspected IA who underwent two-phase whole-body bone SPECT/CT after 550-650 MBq [99mTc]Tc-HDP injection. Forty-eight patients also had ultrasound (US) for peripheral IA, and 42 had MRI for axial IA. The skeleton was segmented into 26 joint areas and analyzed by trained observers using a visual consensus methodology and SUVmax measurements. RESULTS: A total of 1836 joint areas were analyzed, including 1126 peripheral ones (limb joints excluding hips and shoulders). SUVmax was predictive of visually abnormal SPECT joints with high areas under receiver-operating-characteristic (ROC) curves for non-peripheral (BP-SPECT: 0.941 ± 0.017, DEL-SPECT: 0.910 ± 0.014) and especially peripheral (BP-SPECT: 0.980 ± 0.005, DEL-SPECT: 0.939 ± 0.012) joints. An SUVmax threshold-based prediction of visual SPECT abnormalities had high negative predictive values (BP-SPECT: 99.2% (1479/1491), DEL-SPECT: 97.2% (1333/1372)) but low positive predictive values (BP-SPECT: 35.1% (121/345), DEL-SPECT: 51.2% (237/463)). MRI- and US-defined IA were best predicted by a visually abnormal BP-SPECT due to higher specificities than SUVmax thresholds (all p < 0.05). CONCLUSION: On two-phase whole-body bone SPECT/CT, an SUVmax-based IA detection may not replace the conventional visual method. However, given the high negative predictive values provided by SUVmax thresholds, the time-consuming visual analysis of SPECT/CT slices could be confined to the small proportion of joints exceeding these thresholds.
引用
- Rajadhas F, Imbert L, Fiorino M, et al. Standardized uptake value-based analysis of two-phase whole-body bone tomoscintigraphies recorded with a high-speed 360° CZT camera in patients with known or suspected inflammatory arthritis. Eur J Nucl Med Mol Imaging. 2025. PMID: 39969541. doi:10.1007/s00259-025-07150-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。