文献速递肿瘤 PET/CT放射性药物与辐射防护

基于3D扩散模型的全身体PET图像稳健去噪:在多种扫描仪、示踪剂和剂量水平下的评估

Robust whole-body PET image denoising using 3D diffusion models: evaluation across various scanners, tracers, and dose levels.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-02-06

研究提出并验证了一种3D去噪扩散概率模型(3D DDPM),用于全身体PET图像去噪。模型在单一扫描仪高质量数据上训练,并在四种扫描仪、四种示踪剂类型和六种剂量水平的数据集上评估,结果3D DDPM在所有测试条件下均持续优于2D DDPM、3D UNet和3D GAN,其不确定性图方差更低。作者认为该模型可作为全身体PET图像去噪的基础模型,供研究人员直接使用。

要点

  • 3D DDPM在所有测试条件下均持续优于2D DDPM、3D UNet和3D GAN。
  • 模型在四种扫描仪、四种示踪剂类型和六种剂量水平下完成评估。
  • 模型不确定性图方差更低,反映其对输出结果置信度更高。

核心结论

  • 提出的3D DDPM能有效处理剂量水平、扫描仪和示踪剂变化等多种临床场景,作者认为其是PET图像去噪的有前景的基础模型。
  • 作者指出本工作训练好的3D DDPM模型可供研究人员直接用作全身体PET图像去噪方案,代码和模型已在 https://github.com/Miche11eU/PET-Image-Denoising-Using-3D-Diffusion-Model 公开。

研究设计与样本

  • 研究提出并验证了一种3D去噪扩散概率模型(3D DDPM)用于全身体PET图像去噪。
  • 模型在正向扩散阶段逐步向图像注入噪声,在反向扩散过程中学习重建干净数据。
  • 使用Biograph Vision Quadra PET/CT扫描仪的高质量数据训练3D卷积网络以生成得分函数。
  • 训练好的3D DDPM在来自四种扫描仪、四种示踪剂类型和六种剂量水平的数据集上进行评估。

主要发现

  • 3D DDPM在所有测试条件下均持续优于2D DDPM、3D UNet和3D GAN。
  • 3D DDPM的不确定性图方差更低,反映其对输出结果置信度更高。

临床怎么用

  • 作者指出本工作训练好的3D DDPM模型可供研究人员直接用作全身体PET图像去噪方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Whole-body PET imaging plays an essential role in cancer diagnosis and treatment but suffers from low image quality. Traditional deep learning-based denoising methods work well for a specific acquisition but are less effective in handling diverse PET protocols. In this study, we proposed and validated a 3D Denoising Diffusion Probabilistic Model (3D DDPM) as a robust and universal solution for whole-body PET image denoising. METHODS: The proposed 3D DDPM gradually injected noise into the images during the forward diffusion phase, allowing the model to learn to reconstruct the clean data during the reverse diffusion process. A 3D convolutional network was trained using high-quality data from the Biograph Vision Quadra PET/CT scanner to generate the score function, enabling the model to capture accurate PET distribution information extracted from the total-body datasets. The trained 3D DDPM was evaluated on datasets from four scanners, four tracer types, and six dose levels representing a broad spectrum of clinical scenarios. RESULTS: The proposed 3D DDPM consistently outperformed 2D DDPM, 3D UNet, and 3D GAN, demonstrating its superior denoising performance across all tested conditions. Additionally, the model's uncertainty maps exhibited lower variance, reflecting its higher confidence in its outputs. CONCLUSIONS: The proposed 3D DDPM can effectively handle various clinical settings, including variations in dose levels, scanners, and tracers, establishing it as a promising foundational model for PET image denoising. The trained 3D DDPM model of this work can be utilized off the shelf by researchers as a whole-body PET image denoising solution. The code and model are available at https://github.com/Miche11eU/PET-Image-Denoising-Using-3D-Diffusion-Model .

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Yu B, Ozdemir S, Dong Y, et al. Robust whole-body PET image denoising using 3D diffusion models: evaluation across various scanners, tracers, and dose levels. Eur J Nucl Med Mol Imaging. 2025. PMID: 39912940. doi:10.1007/s00259-025-07122-4

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。