文献速递肿瘤 PET/CT放射性药物与辐射防护

用于超低剂量全身PET成像多器官分割的稳健可泛化人工智能:一项多中心跨示踪剂研究

Robust and generalizable artificial intelligence for multi-organ segmentation in ultra-low-dose total-body PET imaging: a multi-center and cross-tracer study.
PubMed 文献 · Eur J Nucl Med Mol Imaging · 2025-02-19

本研究为回顾性研究,开发并验证一种基于三维深度学习的模型,用于在多种成像条件(包括低剂量和非衰减校正扫描)下对PET图像进行多器官自动分割;使用来自多个中心、不同示踪剂的798例患者数据,通过多中心和跨示踪剂测试评估稳健性与泛化性,以CT图像生成的23个器官地面真值标签和Dice相似系数(DSC)评估分割精度。多中心数据集(四个不同机构)中,FDG PET图像在不同剂量缩减因子和校正条件下的平均DSC值为0.834、0.825、0.819和0.816;跨示踪剂数据集中,DOTATATE、FAPI、FDG、Grazytracer和PSMA的平均DSC值分别为0.737、0.573、0.830、0.661和0.708。结论认为该模型在多种成像条件、中心和示踪剂下实现了有效的完全基于PET的多器官分割,具有高稳健性和泛化性,这些发现强调了该模型通过支持超低剂量PET成像来增强临床诊断工作流程的潜力。

要点

  • 多中心数据集(四个机构)中,FDG PET图像在不同剂量缩减因子和校正条件下的平均DSC为0.834、0.825、0.819和0.816。
  • 跨示踪剂数据集中,DOTATATE、FAPI、FDG、Grazytracer和PSMA的平均DSC分别为0.737、0.573、0.830、0.661和0.708。
  • 模型在多种成像条件、中心和示踪剂下实现完全基于PET的多器官分割,具有高稳健性和泛化性。

核心结论

  • 所提出的模型在多种成像条件、中心和示踪剂下实现了有效的完全基于PET的多器官分割,具有高稳健性和泛化性。
  • 这些发现强调了该模型通过支持超低剂量PET成像来增强临床诊断工作流程的潜力。

研究设计与样本

  • 本研究为回顾性研究,采用三维深度学习模型对多种条件下(包括低剂量和非衰减校正扫描)获取的PET图像进行多器官自动分割。
  • 使用来自多个中心、不同示踪剂的798例患者数据集,通过多中心和跨示踪剂测试评估模型的稳健性和泛化性。
  • 以CT图像生成的23个器官地面真值标签,使用Dice相似系数(DSC)评估分割精度。

主要发现

  • 在多中心数据集(来自四个不同机构)中,FDG PET图像在不同剂量缩减因子和校正条件下的平均DSC值分别为0.834、0.825、0.819和0.816。
  • 在跨示踪剂数据集中,模型对DOTATATE、FAPI、FDG、Grazytracer和PSMA的平均DSC值分别为0.737、0.573、0.830、0.661和0.708。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

PURPOSE: Positron Emission Tomography (PET) is a powerful molecular imaging tool that visualizes radiotracer distribution to reveal physiological processes. Recent advances in total-body PET have enabled low-dose, CT-free imaging; however, accurate organ segmentation using PET-only data remains challenging. This study develops and validates a deep learning model for multi-organ PET segmentation across varied imaging conditions and tracers, addressing critical needs for fully PET-based quantitative analysis. MATERIALS AND METHODS: This retrospective study employed a 3D deep learning-based model for automated multi-organ segmentation on PET images acquired under diverse conditions, including low-dose and non-attenuation-corrected scans. Using a dataset of 798 patients from multiple centers with varied tracers, model robustness and generalizability were evaluated via multi-center and cross-tracer tests. Ground-truth labels for 23 organs were generated from CT images, and segmentation accuracy was assessed using the Dice similarity coefficient (DSC). RESULTS: In the multi-center dataset from four different institutions, our model achieved average DSC values of 0.834, 0.825, 0.819, and 0.816 across varying dose reduction factors and correction conditions for FDG PET images. In the cross-tracer dataset, the model reached average DSC values of 0.737, 0.573, 0.830, 0.661, and 0.708 for DOTATATE, FAPI, FDG, Grazytracer, and PSMA, respectively. CONCLUSION: The proposed model demonstrated effective, fully PET-based multi-organ segmentation across a range of imaging conditions, centers, and tracers, achieving high robustness and generalizability. These findings underscore the model's potential to enhance clinical diagnostic workflows by supporting ultra-low dose PET imaging. CLINICAL TRIAL NUMBER: Not applicable. This is a retrospective study based on collected data, which has been approved by the Research Ethics Committee of Ruijin Hospital affiliated to Shanghai Jiao Tong University School of Medicine.

来源:Eur J Nucl Med Mol Imaging,查看原文。版权归原作者所有。

引用

  1. Wang H, Qiao X, Ding W, et al. Robust and generalizable artificial intelligence for multi-organ segmentation in ultra-low-dose total-body PET imaging: a multi-center and cross-tracer study. Eur J Nucl Med Mol Imaging. 2025. PMID: 39969540. doi:10.1007/s00259-025-07156-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。