疑似巨细胞动脉炎患者血管炎症的超声、FDG-PET/CT与MRI深度比较
该嵌套病例对照研究纳入42例疑似巨细胞动脉炎患者,回顾性比较彩色多普勒超声(CDUS)、FDG-PET/CT与MRI的血管壁病变评估表现。三种影像总体诊断性能相当;颞动脉以CDUS和MRI敏感性与特异性最高,椎动脉和上颌动脉以FDG-PET/CT表现较好,但椎动脉观察者间一致性中等。
要点
- 颞动脉评估:CDUS敏感性76%、特异性93%,MRI敏感性60%、特异性100%,两者Kappa均>0.7。
- FDG-PET/CT在椎动脉(敏感性61%、特异性100%,Kappa 0.56)和上颌动脉(敏感性52%、特异性100%,Kappa 0.75)表现较好。
- 颞动脉阳性时三种模态间一致性0.76,但CDUS与FDG-PET/CT间仅0.28;腋动脉CDUS与FDG-PET/CT一致性0.7。
核心结论
- 颞动脉可由CDUS和MRI评估,敏感性良好且特异性高;腋动脉可由CDUS和FDG-PET/CT评估,两者一致性高。
- 椎动脉和上颌动脉可由FDG-PET/CT评估,敏感性和特异性良好,但椎动脉观察者间一致性中等。
研究设计与样本
- 嵌套病例对照研究,连续纳入疑似巨细胞动脉炎患者,共42例。
- 每种影像模态由两名专家回顾性评估,使用Cohen或Fleiss Kappa计算观察者间和观察者内一致性。
- 计算各影像模态的总体诊断性能及单支动脉的敏感性和特异性。
主要发现
- 三种影像模态的总体诊断性能相当。
- 颞动脉:CDUS敏感性76%、特异性93%(Kappa>0.7);MRI敏感性60%、特异性100%(Kappa>0.7)。
- 椎动脉FDG-PET/CT敏感性61%、特异性100%(Kappa 0.56);上颌动脉FDG-PET/CT敏感性52%、特异性100%(Kappa 0.75)。
- 颞动脉阳性时三种模态间一致性0.76,CDUS与FDG-PET/CT间一致性仅0.28。
- 腋动脉CDUS与FDG-PET/CT间一致性0.7。
关键数值与推荐
- 颞动脉CDUS:敏感性76%、特异性93%,Kappa>0.7。
- 颞动脉MRI:敏感性60%、特异性100%,Kappa>0.7。
- 椎动脉FDG-PET/CT:敏感性61%、特异性100%,Kappa 0.56。
- 上颌动脉FDG-PET/CT:敏感性52%、特异性100%,Kappa 0.75。
- 颞动脉阳性时三模态间一致性0.76,CDUS与FDG-PET/CT间0.28;腋动脉CDUS与FDG-PET/CT间0.7。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Giant cell arteritis (GCA) is a difficult to diagnose large vessel vasculitis. CDUS, FDG-PET/CT and MRI are increasingly used for GCA diagnosis. This study aims to assess vascular wall lesions in GCA suspected patients, directly comparing CDUS, FDG-PET/CT and MRI with each other. METHODS: In a nested-case control study, consecutive GCA suspected patients were included. Scans were retrospectively assessed by two experts per imaging modality. Inter- and intraobserver agreement using Cohen's or Fleiss Kappa were calculated to assess agreement between experts, a few duplicated scans and between imaging modalities. Sensitivity and specificity of the imaging modalities for overall diagnostic performance and for individual arteries were calculated. RESULTS: In total, 42 patients were included. Overall diagnostic performance of imaging modalities was comparable. Sensitivity and specificity were highest in the temporal artery for CDUS (76% and 93%; Kappa > 0.7) and MRI (60% and 100%; Kappa > 0.7), and in the vertebral (61% and 100%; Kappa 0.56) and maxillary artery (52% and 100%; Kappa 0.75) for FDG-PET/CT. Agreement between all modalities for a positive temporal artery was 0.76, but only 0.28 between CDUS and FDG-PET/CT. Agreement for the axillary artery was 0.7 between CDUS and FDG-PET/CT. CONCLUSION: The temporal artery can be assessed by CDUS and MRI with good sensitivity and high specificity, and the axillary artery by CDUS and FDG-PET/CT with high agreement between the two modalities. In addition, the vertebral and maxillary artery can be assessed by FDG-PET/CT with good sensitivity and specificity, however the vertebral artery had moderate interobserver agreement.
引用
- van Nieuwland M, Nienhuis PH, Haagsma C, et al. An in-depth comparison of vascular inflammation on ultrasound, FDG-PET/CT and MRI in patients with suspected giant cell arteritis. Eur J Nucl Med Mol Imaging. 2025. PMID: 39903226. doi:10.1007/s00259-025-07088-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。