核医学科碳足迹估算:法国某科室的示例
该研究采用专业咨询公司协助开发的方法,估算法国某核医学科2022年温室气体排放,涵盖直接与间接排放,结果以二氧化碳当量表示。2022年该科完成13303例诊断与治疗操作,碳足迹估计为772吨二氧化碳当量,人员交通占总排放67%。作者结论认为排放主要来自间接排放,这在第三产业中为常见结果。
要点
- 2022年该科13303例诊断与治疗操作对应碳足迹约772吨二氧化碳当量。
- 人员交通占总排放67%,采购占14%,其中放射性示踪剂供应占11.8%。
- 能源消耗占总排放6.9%,影像设备(2台PET/CT、2台SPECT/CT和1台心脏专用CZT相机)占5.5%。
核心结论
- 该科排放主要来自间接排放,这在第三产业中为常见结果。
研究设计与样本
- 采用专业咨询公司协助开发的方法,估算某核医学科温室气体排放,包括直接排放与间接排放,结果以二氧化碳当量汇总。
主要发现
- 2022年该科完成13303例诊断与治疗操作,碳足迹估计达772吨二氧化碳当量。
- 人员交通占总排放67%。
- 采购占总排放14%,其中放射性示踪剂供应占11.8%。
- 能源消耗占总排放6.9%。
- 影像设备(2台PET/CT、2台SPECT/CT和1台心脏专用CZT相机)占总排放5.5%。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
PURPOSE: In order to limit climate changes, we need to reduce the carbon footprint of human activities, including those due to health systems. We performed an estimation of the carbon footprint of our nuclear medicine department using a methodology developed with the help of a specialized consulting firm. METHODS: The estimate of greenhouse gas (GHG) emissions comprises direct and indirect emissions. Direct emissions are due to fuels consumption (by the hospital and by hospital's vehicles), refrigerant leaks and impact of buildings on biomass (land use change). Indirect emissions include upstream and downstream emissions. Upstream emissions are linked to electricity and heating consumption, transport of merchandises, transport of patients and employees, business travels, purchases, and fixed assets. Downstream emissions are due to usage and disposal of manufactured products created by the hospital. Different GHGs (CO2, CH4, N2O…) each have a different global warming potential. To aggregate all GHG emissions, the results were expressed in carbon dioxide equivalent (CO2e). RESULTS: In 2022, 13,303 diagnostic and therapeutic procedures were performed in our department, for an estimated carbon footprint reaching 772 tons of CO2 equivalent. Transport of people accounts for 67% of total emissions. Purchases are responsible for 14% of total emissions, of which 11.8% are due to radiotracers supply. Energy consumption accounts for 6.9% of total emissions. Imaging devices (2 PET/CT, 2 SPECT/CT and 1 cardiac imaging dedicated CZT camera) account for 5.5% of emissions. CONCLUSION: Our emissions are mainly due to indirect emission which is a common result in tertiary sector.
引用
- Godard F, Oosthoek J, Alexis A, et al. Estimation of carbon footprint in nuclear medicine: illustration of a french department. Eur J Nucl Med Mol Imaging. 2025. PMID: 39976702. doi:10.1007/s00259-025-07129-x
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。